Sub topic 9
Checking the Measurement System and Establishing the Baseline
This chapter assumes you understand basic process variation, defect rates, mean, and standard deviation. It also assumes familiarity with Lean Six Sigma roles and the purpose of the DMAIC Measure phase.
Check the measurement system first
A measurement system includes the instrument, method, people, environment, and rules used to record a result. Measurement system analysis (MSA) checks whether the system produces data that are trustworthy enough for analysis.
If the measurement system is poor, the project may treat measurement error as process variation. It may also miss real changes. Do not calculate capability or compare improvement results until the measurement system is acceptable.
For continuous measurements, such as cycle time or weight, common MSA checks include:
- Repeatability: variation when the same person measures the same item repeatedly.
- Reproducibility: variation between different people measuring the same items.
- Bias: the difference between the average measurement and a known reference value.
- Stability: whether measurement performance remains consistent over time.
- Linearity: whether bias changes across the measurement range.
A gage repeatability and reproducibility study, usually called a Gage R&R study, estimates repeatability and reproducibility. The team measures selected parts several times, using several operators. It then separates total observed variation into process variation and measurement variation.
For pass/fail data, use an attribute agreement analysis. Compare each appraiser's decisions with a known standard and with the other appraisers.
The measurement-system decision should be recorded with the method, sample design, results, acceptance rule, and any corrective action.
Calculate the baseline
The baseline describes current performance before improvement. For defect data, defects per million opportunities (DPMO) adjusts the defect count for both the number of units and the number of possible defect opportunities per unit:
\[ DPMO = \frac{\text{defects}}{\text{units} \times \text{opportunities per unit}} \times 1{,}000{,}000 \]
Suppose 500 units contain 27 defects, and each unit has four opportunities. The DPMO is 13,500. A conventional sigma estimate converts the long-term yield to a short-term sigma level by adding a 1.5 sigma shift.
from statistics import NormalDist
defects = 27
units = 500
opportunities_per_unit = 4
dpmo = defects / (units * opportunities_per_unit) * 1_000_000
yield_rate = 1 - dpmo / 1_000_000
sigma_level = NormalDist().inv_cdf(yield_rate) + 1.5
print(f"DPMO: {dpmo:.0f}")
print(f"Sigma level: {sigma_level:.2f}")Expected output is approximately:
| Measure | Result |
|---|---|
| DPMO | 13,500 |
| Sigma level | 3.71 |
For a continuous output with lower and upper specification limits, calculate capability after confirming stable data. Cp measures potential capability from process spread:
\[ Cp = \frac{USL - LSL}{6s} \]
Cpk also considers centering:
\[ Cpk = \min\left(\frac{USL-\bar{x}}{3s}, \frac{\bar{x}-LSL}{3s}\right) \]
Here, USL and LSL are specification limits, \(\bar{x}\) is the process mean, and \(s\) is the standard deviation. A low Cpk can result from excessive spread, poor centering, or both. DPMO and capability answer related but different questions, so report the measure that matches the data and customer requirement.
Exercise
Why should a team complete an MSA before reporting a process capability value?
Show answer
Capability uses measured variation and position relative to specification limits. If measurement error is large, the reported capability may describe the measurement system instead of the process.