02Chapter 2: RMS values: the DC-equivalent heating effectThis chapter assumes you know Ohm's law, basic trigonometry, and the idea of a sinusoidal waveform with amplitude, frequency, and phase. It explains the RMS value, which every later power calculation in this tutorial relies on.3 min read
03Chapter 3: Phasors and the phase angle between voltage and currentThis chapter assumes you know Ohm's law, basic trigonometry, how resistors, inductors and capacitors relate voltage to current, and how to convert complex numbers between rectangular and polar form. It builds on the previous chapters on sinusoids and RMS values.2 min read
04Chapter 4: Impedance of R, L, and C loadsThis chapter assumes you know Ohm's law, the voltage-current relationships of resistors, inductors, and capacitors, and complex numbers in rectangular and polar form. It also assumes you can write a sinusoid as a phasor. Impedance lets you treat AC circuits with the same algebra you use for DC resis2 min read
06Chapter 6: Real power: the average that does workThis chapter assumes you can read sinusoids and RMS values, use phasors and impedance, and apply basic trigonometric identities. It defines real power as the average of instantaneous power and shows how to calculate it.3 min read
07Chapter 7: Reactive power: energy exchanged with fieldsThis chapter assumes you know phasors, impedance of R, L and C, and how instantaneous power p(t) = v(t)·i(t) behaves. The previous chapter showed that the average of p(t) is real power. This chapter covers the part that averages to zero.2 min read
08Chapter 8: Apparent power: what the source and wiring must carryThis chapter assumes you can compute RMS values, read a phasor angle, and find the impedance of a series R-L load. It builds on real power P and reactive power Q from the previous two chapters.3 min read
09Chapter 9: The power triangleThis chapter assumes you know RMS values, phasors, impedance, and the definitions of real power P (W), reactive power Q (var), and apparent power S (VA). It shows how the three fit into one right triangle and how to use that triangle to solve problems.2 min read
10Chapter 10: Power factor and why utilities careThis chapter assumes you can compute RMS values, work with phasors and impedance, and know that real power P is in watts, reactive power Q is in var, and apparent power S is in VA, with S² = P² + Q². Here we define power factor and show why it affects cost and wiring.2 min read
11Chapter 11: Lagging and leading power factor: inductive vs capacitive loadsThis chapter assumes you know phasors, impedance of R, L, and C, and the power triangle from the earlier chapters. Power factor (pf) is the ratio P/S, so it is a number between 0 and 1. That number does not say whether the current is behind or ahead of the voltage. The words "lagging" and "leading" 3 min read
12Chapter 12: Complex power S = V I* from phasorsThis chapter assumes you can multiply and divide complex numbers in polar and rectangular form. It also assumes you know phasors and impedance from the earlier chapters.2 min read
13Chapter 13: Correcting power factor with a shunt capacitorThis chapter assumes you know the power triangle, that inductive loads have a lagging power factor, and that a capacitor supplies reactive power. Here you will size a capacitor for a target power factor.3 min read
14Chapter 14: Power in balanced three-phase systemsThis chapter assumes you know real, reactive, and apparent power, the power triangle, and phasors. It extends them to balanced three-phase circuits, the form in which most industrial power is delivered.3 min read