02Chapter 2: RMS values: the DC-equivalent heating effectThis chapter assumes you know Ohm's law, the basic trigonometry of sine and cosine, and how a resistor relates voltage to current. You should also be comfortable with the idea of a sinusoidal waveform that has an amplitude, a frequency, and a phase. Everything that follows about power depends on get6 min read
03Chapter 3: Phasors and the phase angle between voltage and currentThis chapter assumes you can do Ohm's law and Kirchhoff's laws, use basic trigonometry, recall the voltage-current relationships of resistors, inductors, and capacitors, and convert complex numbers between rectangular and polar form. It builds the tool that every later power calculation uses: the ph5 min read
04Chapter 4: Impedance of R, L, and C loadsThis chapter assumes you know Ohm's law, the voltage-current relationships of resistors, inductors, and capacitors, complex numbers in rectangular and polar form, and the phasor idea from the previous chapter. Impedance is the quantity that turns a phasor voltage into a phasor current. The phase ang7 min read
05Chapter 5: Instantaneous power and why it oscillatesThis chapter assumes you can work with sinusoids in the form $A\sin(\omega t + \theta)$. It also assumes you know the product-to-sum trig identities and the voltage-current relationships of R, L, and C. Both are covered in the earlier chapters on phasors and impedance. Here we build the time-domain 6 min read
06Chapter 6: Real power: the average that does workThis chapter derives real power from the instantaneous power p(t). It then shows what each load type does to that average and how to compute and check it. It assumes you know RMS values, phasors, and impedance from earlier chapters. It also assumes you can use trigonometric product identities and th7 min read
07Chapter 7: Reactive power: energy exchanged with fieldsThis chapter assumes you can write a sinusoid as a phasor, know that an inductor has reactance XL = ωL and a capacitor has XC = 1/(ωC), and have met instantaneous power p(t) = v(t) i(t) and real power P. We now isolate the part of p(t) that averages to zero and explain why it still matters.6 min read
08Chapter 8: Apparent power: what the source and wiring must carryThis chapter assumes you can already compute RMS values, express voltage and current as phasors, and calculate real power P and reactive power Q for a load. It uses P in watts (W) and Q in volt-amperes reactive (var). Here you add apparent power, the quantity that determines how much current a sourc6 min read
09Chapter 9: The power triangleThis chapter assumes you can do phasor arithmetic and basic trigonometry. It also assumes you already know real power P (W), reactive power Q (var), and apparent power S (VA) as separate quantities. Here you combine them into one right triangle and use it to solve problems.6 min read
10Chapter 10: Power factor and why utilities careThis chapter assumes you can compute RMS values, write voltage and current as phasors, and read real power P, reactive power Q, and apparent power S off the power triangle. You should also be comfortable with complex numbers in polar form.6 min read
11Chapter 11: Lagging and leading power factor: inductive vs capacitive loadsThis chapter assumes you can compute real, reactive, and apparent power from the power triangle and that you know phasors and impedance. The earlier chapters on those topics cover that background. Here you will learn what the words "lagging" and "leading" attach to, how the sign of reactive power fo6 min read
12Chapter 12: Complex power S = V I* from phasorsThis chapter assumes you can convert between rectangular and polar form, that you know impedance Z = R + jX, and that you know real power P, reactive power Q, apparent power S and power factor from the earlier chapters. All phasors here use RMS magnitudes unless stated otherwise.6 min read
13Chapter 13: Correcting power factor with a shunt capacitorThis chapter assumes you can compute real, reactive and apparent power from a power triangle, and that you know the capacitor current relation I = V/Xc. You should also be comfortable with complex numbers in rectangular form. The goal is to size a capacitor that raises a lagging power factor to a ta6 min read
14Chapter 14: Power in balanced three-phase systemsLarge loads and almost all generation and transmission use three-phase power. This chapter extends the single-phase quantities P, Q, S, and power factor to balanced three-phase systems. It assumes you know phasors, impedance, complex power S = V I*, and the power triangle from earlier chapters. You 6 min read
15Chapter 15: Distorted waveforms: displacement vs true power factorThis chapter assumes you know RMS values, phasors, the power triangle, and the definition of power factor (pf) as P/S. You should also know that a periodic waveform can be written as a sum of sinusoids (a Fourier series). The earlier chapters assumed pure sinusoids. Here the current is not sinusoida6 min read