Sub topic 6
Self inductance
This chapter assumes you know magnetic flux, Faraday's law and Lenz's law from the earlier chapters. It also assumes you know the magnetic field of a long solenoid and can do simple derivatives. Self inductance is the property of a coil that makes it oppose any change in its own current.
The idea
A current in a coil produces a magnetic field. That field passes through the coil's own turns, so the coil has its own flux. If the current changes, the flux changes. By Faraday's law, an emf appears in the same coil. This is self induction.
For a coil of N turns, the flux linkage is proportional to the current:
N Φ = L I
The constant L is the self inductance (or inductance) of the coil. It depends only on geometry (shape, number of turns, area, length) and on the material in the core. It does not depend on the current.
- Unit: henry (H). 1 H = 1 V s / A = 1 Wb / A.
- Dimensions: [M L² T⁻² A⁻²].
Induced emf in terms of L
Apply Faraday's law to N Φ = L I:
e = − d(NΦ)/dt = − L dI/dt
The minus sign is Lenz's law. The induced emf (often called back emf) opposes the change in current:
- If the current increases, the emf points against the current and slows the rise.
- If the current decreases, the emf points along the current and slows the fall.
A coil resists a change in current, not the current itself. This is why L is called the electrical analogue of mass: it gives the circuit "inertia". A steady current produces no induced emf.
A useful check: if the current changes at 2 A/s and the emf is 4 V in magnitude, then L = 4 / 2 = 2 H.
Inductance of a long solenoid
Take a solenoid of length l, cross-sectional area A and N turns, so n = N/l turns per unit length. Assume l is much larger than the radius, so the field is uniform inside.
- Field inside: B = μ₀ n I = μ₀ N I / l.
- Flux through one turn: Φ = B A.
- Flux linkage: N Φ = μ₀ N² A I / l.
- Compare with N Φ = L I:
L = μ₀ N² A / l = μ₀ n² A l
With a core of relative permeability μᵣ, replace μ₀ by μ = μ₀ μᵣ:
L = μ₀ μᵣ N² A / l
So L scales with the square of the number of turns. Doubling the turns on the same length quadruples L. Inserting an iron core can raise L by a factor of hundreds or thousands.
The expression L = μ₀ n² A l is the volume form: L = μ₀ n² × (volume of the solenoid).
Other common shapes
| Coil | Self inductance |
|---|---|
| Long solenoid, air core | μ₀ N² A / l |
| Long solenoid, core of permeability μ | μ N² A / l |
| Circular coil, N turns, radius r, field at centre (rough estimate) | order μ₀ N² π r / 2 |
| Toroid, N turns, mean radius R, cross-section A | μ₀ N² A / (2π R) |
For NEET the solenoid result is the one used most often. The toroid formula follows the same steps with B = μ₀ N I / (2πR).
Dependence on geometry: a quick comparison
The factors that change L, and the direction of change:
- More turns: L increases as N².
- Larger area: L increases in proportion to A.
- Longer length at the same N: L decreases, since L ∝ 1/l.
- Iron core: L increases by a factor μᵣ.
A common mistake is to say L depends on current. It does not, as long as the core is not magnetically saturated. For iron cores, μᵣ varies with the field, so L can change at high current. NEET problems treat L as constant.
Worked example 1: solenoid inductance
A solenoid has 500 turns, length 0.25 m and cross-sectional area 4 × 10⁻⁴ m². Find L in air.
L = μ₀ N² A / l = (4π × 10⁻⁷)(500²)(4 × 10⁻⁴) / 0.25
- N² = 2.5 × 10⁵
- Numerator: 4π × 10⁻⁷ × 2.5 × 10⁵ × 4 × 10⁻⁴ = 4π × 10⁻⁵ ≈ 1.257 × 10⁻⁴
- Divide by 0.25: L ≈ 5.03 × 10⁻⁴ H ≈ 0.50 mH
Worked example 2: emf from changing current
The current in a coil with L = 0.5 H falls uniformly from 4 A to 1 A in 0.1 s. Find the induced emf.
dI/dt = (1 − 4) / 0.1 = −30 A/s
e = −L dI/dt = −0.5 × (−30) = +15 V
The emf is 15 V and acts in the direction of the current, opposing its decrease.
Checking the numbers in code
This script computes L for a solenoid and the emf for a given rate of change of current.
import math
mu0 = 4 * math.pi * 1e-7 # permeability of free space, T m/A
N = 500 # turns
length = 0.25 # m
area = 4e-4 # m^2
mu_r = 1.0 # relative permeability (air core)
L = mu_r * mu0 * N**2 * area / length
print(f"L = {L * 1e3:.3f} mH")
dI = 1.0 - 4.0 # change in current, A
dt = 0.1 # s
L2 = 0.5 # H
emf = -L2 * dI / dt
print(f"emf = {emf:.1f} V")Why a switch sparks
Suppose a coil carries a steady current and you open the switch. The current tries to drop to zero in a very short time, so dI/dt is large and negative. The induced emf L |dI/dt| becomes very large and acts in the direction of the old current. It can drive a spark across the switch contacts. This is why circuits with large inductors (motors, relay coils) use a flyback diode or a spark-suppression circuit.
Bifilar winding: zero inductance
A non-inductive resistor is made by folding a wire in half and winding it so that two adjacent wires carry equal currents in opposite directions. The magnetic fields cancel, so the net flux is nearly zero and L is almost zero. Resistance boxes use this method so that they behave as pure resistances in AC.
Common errors
- Writing e = −L I instead of e = −L dI/dt. Emf depends on the rate of change of current, not the current.
- Forgetting that L ∝ N², not N. The flux per turn also scales with N.
- Using the wrong direction for the emf. It opposes the change in current, not the current.
- Mixing up flux Φ (per turn) and flux linkage N Φ.
- Treating a closed switch with steady current as if it still produces an emf. With dI/dt = 0 there is none.
Exercise
A long air-core solenoid has 1000 turns, length 0.5 m and cross-sectional area 2 × 10⁻³ m². (a) Find its self inductance. (b) The current through it changes from 0 to 5 A in 0.2 s at a uniform rate. Find the magnitude of the induced emf. (c) If the number of turns is doubled over the same length and area, by what factor does L change?
Show answer
(a) L = μ₀ N² A / l = (4π × 10⁻⁷)(10⁶)(2 × 10⁻³) / 0.5 = 5.03 × 10⁻³ H, about 5.0 mH. (b) dI/dt = 5 / 0.2 = 25 A/s, so |e| = L dI/dt = 5.03 × 10⁻³ × 25 ≈ 0.126 V. (c) L is proportional to N², so doubling N makes L four times larger.
Exercise
A coil has L = 2 H. At one instant the current is 3 A and is increasing at 4 A/s. What is the magnitude and direction of the induced emf at that instant? Does the value 3 A affect the answer?
Show answer
|e| = L dI/dt = 2 × 4 = 8 V. Since the current is increasing, the emf opposes the current. The value 3 A does not affect the emf, which depends only on the rate of change dI/dt.