Sub topic 1
Magnetic flux and how it changes
Prerequisites
This chapter assumes you already know the following:
- The magnetic field B as a vector, measured in tesla (T), and the force on a moving charge or a current-carrying wire.
- Basic trigonometry: sine and cosine of an angle, and how cosine behaves near 0°, 90° and 180°.
- Vectors and the dot product of two vectors.
- Simple derivatives, and the idea of a rate of change.
Everything else is built here. This chapter sets up the quantity that Faraday's law, Lenz's law, motional emf and the AC generator all depend on.
What magnetic flux measures
Magnetic flux is a measure of how much magnetic field passes through a surface. Picture field lines as thin streams of water and the surface as a hoop held in the stream. The number of lines passing through the hoop depends on three things:
- how strong the field is,
- how large the hoop is,
- how the hoop is tilted relative to the stream.
For a flat surface in a uniform field, the flux is
Φ = B · A = B A cos θ
Here A is the area vector. Its magnitude is the area of the surface, and its direction is the normal (perpendicular) to the surface. The angle θ is the angle between B and this normal. It is not the angle between B and the plane of the surface. This is the most common slip in NEET problems.
The SI unit of flux is the weber (Wb), where 1 Wb = 1 T·m². Flux is a scalar. It can be positive, negative or zero.
How the angle changes the flux
The cosine factor gives three cases worth memorising.
| Orientation of the surface | Angle θ between B and normal | Flux |
|---|---|---|
| Plane perpendicular to the field (normal along B) | 0° | B A (maximum, positive) |
| Plane parallel to the field (normal perpendicular to B) | 90° | 0 |
| Plane perpendicular to the field, normal opposite to B | 180° | −B A (maximum, negative) |
If a problem gives the angle α between the field and the plane, then θ = 90° − α and the flux is B A sin α. Check which angle you were given before you write the formula.
Flux through a coil with many turns
A coil of N turns, each with the same area, links the flux N times. The total flux linkage is
N Φ = N B A cos θ
Faraday's law, in the next chapter, uses this flux linkage. For now, remember that a single-turn calculation gives the flux through one loop, and you multiply by N to get the linkage of the coil.
Non-uniform fields
When the field varies over the surface, or the surface is curved, you split the surface into tiny patches. Each patch has area vector dA and sees an almost uniform field. The total flux is the sum of the contributions:
Φ = ∫ B · dA
For NEET, the most common case is a field that depends on distance from a long straight wire. You then slice the surface into thin strips at a fixed distance from the wire and integrate over the strips. The uniform-field formula is the case you will use most often.
Magnetic field lines always form closed loops, because no isolated magnetic poles have been observed. As a result, the net flux through any closed surface is zero:
∮ B · dA = 0
This is Gauss's law for magnetism. Flux entering a closed surface equals flux leaving it.
Four ways to change the flux
The flux Φ = B A cos θ depends on three quantities. Changing any of them changes the flux, and that change is what later produces an induced emf.
- Change B. Move a magnet toward or away from the loop, or change the current in a nearby coil.
- Change A. Stretch, squeeze or fold the loop, or slide a conducting rod along rails so the enclosed area grows.
- Change θ. Rotate the loop in the field. This is how an AC generator works.
- Any combination of the above.
The rate of change of flux is dΦ/dt. For a constant rate, it is ΔΦ / Δt. Its unit is Wb/s, which is the same as the volt. This is why the induced emf can be written directly as a rate of change of flux.
Worked example: flux and its change
A square loop of side 10 cm lies in a uniform field of 0.5 T. Initially the normal to the loop is along the field. The loop is then turned through 60°. Find the initial flux, the final flux and the change in flux.
- Area: A = (0.10 m)² = 0.01 m².
- Initial flux: Φ₁ = B A cos 0° = 0.5 × 0.01 × 1 = 5.0 × 10⁻³ Wb.
- Final flux: Φ₂ = B A cos 60° = 0.5 × 0.01 × 0.5 = 2.5 × 10⁻³ Wb.
- Change: ΔΦ = Φ₂ − Φ₁ = −2.5 × 10⁻³ Wb.
The negative sign shows that the flux decreased. If the turn took 0.05 s, the average rate of change would be ΔΦ/Δt = −2.5 × 10⁻³ / 0.05 = −0.05 Wb/s.
You can check this with a short program.
import math
B = 0.5 # field in tesla
side = 0.10 # side of the square loop in metres
A = side ** 2 # area in m^2
def flux(theta_deg):
return B * A * math.cos(math.radians(theta_deg))
phi_1 = flux(0)
phi_2 = flux(60)
dt = 0.05 # time taken to turn, in seconds
print(f"initial flux = {phi_1:.4e} Wb")
print(f"final flux = {phi_2:.4e} Wb")
print(f"change = {phi_2 - phi_1:.4e} Wb")
print(f"average rate = {(phi_2 - phi_1) / dt:.4f} Wb/s")A rotating loop and a flipped loop
Two cases appear again and again in NEET.
A loop turned through 180°. The flux changes from +B A to −B A, so ΔΦ = −2 B A. Students often write zero because the loop looks the same afterwards. The sign of the flux has reversed, and the magnitude of the change is 2 B A.
A loop rotating at constant angular speed ω. Take θ = ωt. Then Φ = B A cos ωt, and
dΦ/dt = −B A ω sin ωt
The rate of change is largest when the flux itself is zero (sin ωt = 1). It is zero when the flux is at its maximum. This inverse relationship matters in the AC generator chapter. The emf follows the rate of change of flux, not the flux.
Common errors
- Using the wrong angle. Measure θ from the normal to the surface, not from the surface.
- Forgetting N. For a coil, flux linkage is N B A cos θ.
- Ignoring sign. Flux through a flipped loop is negative, so ΔΦ is not zero after a 180° turn.
- Mixing units. Convert cm² to m² and gauss to tesla (1 G = 10⁻⁴ T) before computing.
- Assuming a magnet's motion is needed. Any change in B, A or θ changes the flux. The magnet is only one way to do it.
Exercise
A circular coil of 50 turns and radius 10 cm is placed in a uniform field of 0.4 T. The plane of the coil makes an angle of 30° with the field. Find (a) the flux through one turn and (b) the flux linkage of the coil. Then find the change in flux through one turn if the coil is rotated until its plane is perpendicular to the field.
Show answer
The area is A = π r² = π × (0.10)² = 0.0314 m². The plane makes 30° with the field, so the normal makes θ = 60° with the field. (a) Φ = B A cos 60° = 0.4 × 0.0314 × 0.5 = 6.28 × 10⁻³ Wb. (b) The flux linkage is N Φ = 50 × 6.28 × 10⁻³ = 0.314 Wb. When the plane is perpendicular to the field, θ = 0°, so Φ = B A = 0.4 × 0.0314 = 1.256 × 10⁻² Wb. The change is 1.256 × 10⁻² − 6.28 × 10⁻³ = 6.28 × 10⁻³ Wb (an increase).
Exercise
A flat loop of area 0.02 m² has its normal along a uniform field of 0.3 T. The loop is flipped through 180° in 0.1 s. Find the change in flux and the average rate of change of flux.
Show answer
Initial flux = B A cos 0° = 0.3 × 0.02 = 6 × 10⁻³ Wb. After the flip, θ = 180°, so the flux is −6 × 10⁻³ Wb. The change is ΔΦ = −1.2 × 10⁻² Wb. The average rate is ΔΦ/Δt = −1.2 × 10⁻² / 0.1 = −0.12 Wb/s, so its magnitude is 0.12 Wb/s.