Sub topic 5
Eddy currents: uses and losses
This chapter assumes you know Faraday's law, Lenz's law and motional emf from the earlier chapters. It also assumes you can handle Ohm's law and basic power formulas. Here those ideas are applied to induced currents that flow in bulk pieces of metal instead of in wires.
What eddy currents are
A coil of wire gives the induced current a fixed path. A solid metal block gives it no fixed path. When the magnetic flux through a block changes, Faraday's law induces an emf in every closed loop you could draw inside the metal. Because the metal conducts, these emfs drive currents in closed, swirling loops. These loops are called eddy currents. The name comes from the eddies you see in flowing water.
Eddy currents appear in two situations:
- A piece of metal sits in a magnetic field that changes with time. A transformer core is an example.
- A piece of metal moves through a magnetic field, or through a region where the field is non-uniform. A pendulum swinging between magnet poles is an example.
In both cases the flux linked with some loop inside the metal changes. Faraday's law then gives an emf, and the low resistance of the metal makes the current large.
Direction and the effect of Lenz's law
The direction of each eddy current follows Lenz's law. The current opposes the change in flux that causes it. For a moving conductor, the eddy currents experience a magnetic force that opposes the motion. This is a braking force. The kinetic energy you lose does not vanish. It becomes thermal energy in the metal, because the eddy currents flow through the metal's resistance.
Consider a metal plate swinging like a pendulum between the poles of a magnet. As the solid plate enters the field, the flux through it increases and eddy currents appear. The force on those currents opposes the swing, so the plate slows and stops quickly. If the plate has slots cut in it, the eddy currents are broken up and weakened. The slotted plate then swings much more freely.
Why eddy currents are large
Take one loop of radius r inside a metal slab. The emf around it is the rate of change of flux, so it is proportional to the area and to the rate dB/dt. The current is that emf divided by the loop's resistance. A bulk piece of metal has a low resistance along such loops, so the current can reach hundreds of amperes. The heating power is I²R, or equivalently emf²/R, and it grows rapidly as the field changes faster.
For a sinusoidal field the emf is proportional to the frequency f and to the peak field B₀. The power lost to eddy currents in a given piece of metal therefore scales roughly as f²B₀². Doubling the frequency makes the heating about four times larger. NEET usually asks only for this qualitative dependence, not a derivation.
Useful applications
Eddy currents are useful in several devices. In each one, the heating or the braking effect is put to work deliberately.
- Induction furnace. A metal sample is placed inside a coil carrying a high-frequency alternating current. The changing flux induces strong eddy currents in the sample. Their heating melts the metal. Heating happens inside the metal, so no flame or contact is needed. The metal can be melted in a vacuum, which keeps it free from contamination.
- Magnetic braking. Some trains and roller coasters carry electromagnets near a metal rail or fin. When the brake is on, eddy currents appear in the metal and oppose the motion. The braking force acts without contact and has no wear. It gets weaker as the speed falls, so another brake is needed to hold the vehicle still.
- Electromagnetic damping. Galvanometers and some balances use a metal frame or core. The coil swings and eddy currents in the frame oppose the motion. The pointer settles quickly instead of oscillating for a long time. A pointer that settles without overshooting is called dead-beat.
- Induction cooktops. A coil under the surface produces an alternating field. It induces eddy currents in the base of a metal pan, which heats the pan directly. The glass surface itself stays cooler.
- Metal detectors. An alternating field induces eddy currents in a nearby metal object. Those currents produce their own field, and the detector senses the change.
Harmful effects and how they are reduced
In a transformer, motor or generator, the iron core sits in an alternating field. Eddy currents in the core waste energy as heat. This lowers the efficiency and can overheat the machine. Engineers reduce the loss in two ways.
- Laminated cores. The core is built from thin sheets of iron, each coated with insulating varnish. The sheets are stacked parallel to the field lines. The insulation forces each eddy current into a small loop in one thin sheet. A small loop encloses less flux and has a smaller emf, so the current and the I²R loss both drop sharply.
- High-resistivity material. Adding silicon to the iron raises its resistivity, which lowers the eddy current for the same emf.
The idea of slotting a plate, seen earlier, is the same principle. Cutting the metal reduces the area of the loops that can form.
# Compare the eddy-current heating of one solid core with a laminated core.
# Model: the loop emf scales with loop area, so for a slab of thickness t
# the loss scales as t^2 for the same field and frequency.
def relative_loss(thickness_mm: float, reference_mm: float) -> float:
return (thickness_mm / reference_mm) ** 2
solid = 10.0 # mm, one solid block
sheet = 0.5 # mm, one lamination
n_sheets = int(solid / sheet)
loss_one_sheet = relative_loss(sheet, solid)
# Each sheet carries a share of the total volume, so total loss is
# the per-sheet loss weighted by its volume fraction, summed over sheets.
total_laminated = n_sheets * loss_one_sheet * (sheet / solid)
print(f"sheets = {n_sheets}")
print(f"laminated loss relative to solid = {total_laminated:.4f}")This model gives a laminated loss of 0.0025 of the solid core's loss. The exact number depends on the geometry, but the trend is real. Thinner sheets cut the loss strongly.
Common errors
- Thinking eddy currents need a wire. They flow inside any conductor, including a solid block. They do not need a defined circuit.
- Forgetting that the braking is not a loss of energy. The kinetic energy becomes heat. Energy is conserved.
- Using a non-conductor. A plastic or wooden plate does not show the effect, because the induced emf cannot drive a current.
- Laminating the wrong way. The sheets must lie parallel to the field. Sheets placed across the field lines leave the large loops intact.
- Expecting a stationary magnet to induce eddy currents. A steady field and a stationary conductor give no change of flux, so there are no eddy currents.
Summary table
| Feature | Useful case | Harmful case |
|---|---|---|
| Cause | Flux changes through bulk metal | Flux changes through a core |
| Effect | Heating or braking | Wasted heat, lower efficiency |
| Example | Induction furnace, magnetic brake | Transformer core, motor armature |
| Remedy or tool | Choose frequency and coil design | Lamination, silicon steel, slots |
Exercise
A solid copper disc swings as a pendulum between the poles of a strong magnet and stops after a few swings. The same disc with several deep slots cut in it swings for much longer. Explain both observations, and say where the lost kinetic energy goes.
Show answer
The moving disc cuts through a region of non-uniform flux, so the flux through loops in the disc changes. Faraday's law induces emf, and the low resistance of the copper allows large eddy currents. By Lenz's law, the force on these currents opposes the motion, so the disc stops quickly. The slots cut the large loops, which lowers the emf and raises the effective resistance of each path. The eddy currents and the braking force are then much smaller, so the disc swings longer. The kinetic energy is converted into heat (I²R) in the copper.
Exercise
Why is the core of a transformer made of thin insulated iron sheets rather than one solid block, and how must the sheets be oriented relative to the magnetic field?
Show answer
A solid core would carry large eddy currents driven by the alternating flux, and the I²R heating would waste energy and heat the transformer. Thin sheets coated with insulating varnish confine each eddy current to a small loop with a small enclosed flux, so the emf and the loss are much lower. The sheets must lie parallel to the field lines, so that the field passes along the sheets and does not cross them.