Sub topic 16
Power in AC circuits and power factor
This chapter assumes you know phasors, the reactances XL = ωL and XC = 1/(ωC), and the impedance of a series LCR circuit, Z = √(R² + (XL − XC)²). It also assumes you can average a sinusoid over one cycle. The goal is to find the average power a source delivers and to see why a circuit's phase angle controls it.
Instantaneous power
Take a series circuit driven by a source with these quantities:
- v = V₀ sin ωt
- i = I₀ sin(ωt − φ)
Here φ is the angle by which the current lags the voltage. It is positive for an inductive circuit and negative for a capacitive one. The instantaneous power delivered by the source is p = v·i. Using sin A sin B = ½[cos(A − B) − cos(A + B)]:
p = ½ V₀I₀ cos φ − ½ V₀I₀ cos(2ωt − φ)
The first term is constant. The second oscillates at twice the supply frequency and averages to zero over a cycle. So the average power is:
Pavg = ½ V₀I₀ cos φ = Vrms I_rms cos φ
Here cos φ is the power factor. The product Vrms Irms is the apparent power, measured in volt-amperes (VA). The real power in watts is the apparent power multiplied by cos φ.
Power factor in terms of R and Z
The phasor triangle gives tan φ = (XL − XC)/R and cos φ = R/Z. Substituting Irms = Vrms/Z:
Pavg = Vrms Irms (R/Z) = Irms² R
This agrees with the physical picture. Only the resistor dissipates energy. Inductors and capacitors store energy during part of a cycle and return it in the rest.
| Circuit | Phase angle φ | Power factor | Average power |
|---|---|---|---|
| Pure resistor | 0 | 1 | V_rms I_rms |
| Pure inductor | +90° | 0 | 0 |
| Pure capacitor | −90° | 0 | 0 |
| Series LCR, X_L > X_C | between 0 and 90° | R/Z | I_rms² R |
| Series LCR at resonance | 0 | 1 | V_rms²/R |
Where the power goes
The diagram shows how the power flow splits in a general circuit.
For a pure inductor, the source supplies energy while the current grows and takes it back while the current falls. For a pure capacitor, energy is stored in the electric field while charging and returned during discharge. In both cases the net energy per cycle is zero, which is why φ = ±90° gives zero average power.
Computing power numerically
The script below finds the reactances, impedance, rms current, power factor, average power and resonant frequency for a series LCR circuit.
import math
R = 100.0 # ohm
L = 0.5 # henry
C = 20e-6 # farad
V_rms = 220.0 # volt
f = 50.0 # hertz
w = 2 * math.pi * f
XL = w * L
XC = 1 / (w * C)
Z = math.sqrt(R**2 + (XL - XC)**2)
I_rms = V_rms / Z
power_factor = R / Z
P_avg = V_rms * I_rms * power_factor
f_res = 1 / (2 * math.pi * math.sqrt(L * C))
print(f"XL = {XL:.1f} ohm, XC = {XC:.1f} ohm, Z = {Z:.1f} ohm")
print(f"I_rms = {I_rms:.3f} A, power factor = {power_factor:.3f}")
print(f"average power = {P_avg:.1f} W")
print(f"resonant frequency = {f_res:.1f} Hz")The values are XL ≈ 157.1 Ω and XC ≈ 159.2 Ω, so the two nearly cancel and Z ≈ 100 Ω. The power factor is almost 1 and Pavg ≈ 484 W. The resonant frequency is about 50.3 Hz, which is close to the 50 Hz supply. That is why the circuit behaves almost like a pure resistor. You can check the power with Irms² R, which gives the same answer.
Why a low power factor is costly
A device needs a certain real power P. At a fixed supply voltage, the current drawn is:
Irms = P / (Vrms cos φ)
A smaller cos φ forces a larger current for the same useful power. The line resistance r then wastes I² r in the transmission wires. Heating of the cables and generators grows with the square of the current, so a poor power factor wastes energy and needs thicker cables.
Industrial loads such as motors are inductive, so the current lags. A capacitor connected in parallel with the load supplies the reactive current locally. This raises cos φ toward 1 without changing the real power the load uses. Power companies charge penalties for low power factor for this reason.
Worked example
A coil with R = 30 Ω and X_L = 40 Ω is connected to a 200 V rms supply.
- Z = √(30² + 40²) = 50 Ω.
- I_rms = 200/50 = 4 A.
- cos φ = R/Z = 30/50 = 0.6.
- P_avg = 200 × 4 × 0.6 = 480 W.
- Check: I² R = 16 × 30 = 480 W.
The apparent power is 800 VA, but only 480 W is converted to heat.
Common errors
- Using peak values without the ½. P_avg = ½ V₀I₀ cos φ. If you use V₀I₀ cos φ you get twice the correct answer.
- Computing power as V_rms²/R for a non-resonant circuit. That formula holds only when the voltage across R is the full supply voltage, that is, at resonance. In general use Irms² R or Vrms I_rms cos φ.
- Taking the power factor as sin φ. In the standard φ convention, the power factor is cos φ. Check the phasor triangle: R is the adjacent side, so cos φ = R/Z.
- Assuming a capacitor or inductor dissipates energy. An ideal one does not. Real coils have resistance, and that resistance is what dissipates power.
- Forgetting that the power factor is unitless and lies between 0 and 1. It does not depend on whether the circuit is inductive or capacitive, only on |φ|.
Exercises
Exercise
A series circuit has R = 60 Ω, XL = 100 Ω and XC = 20 Ω, and is connected to a 100 V rms supply. Find the rms current, the power factor and the average power.
Show answer
Z = √(60² + (100 − 20)²) = √(3600 + 6400) = 100 Ω. Irms = 100/100 = 1 A. Power factor = R/Z = 60/100 = 0.6. Pavg = 100 × 1 × 0.6 = 60 W, which matches I²R = 1 × 60 = 60 W.
Exercise
A pure capacitor is connected to an AC source and draws an rms current of 2 A. What is the average power consumed, and why?
Show answer
Zero. The phase difference is 90°, so cos φ = 0 and Pavg = Vrms I_rms cos 90° = 0. The capacitor stores energy while charging and returns it all while discharging, so the net energy absorbed per cycle is zero.