Sub topic 7
Mutual inductance
This chapter assumes you know Faraday's law, Lenz's law and self inductance from the earlier chapters. It also assumes you can read a flux expression such as N B A cos θ. Here you will see how a changing current in one coil produces an emf in a neighbouring coil. This is the principle behind the transformer, which comes later in the tutorial.
The idea
Place two coils near each other. Send a current I₁ through coil 1. This current produces a magnetic field, and part of that field passes through coil 2. If I₁ changes, the flux through coil 2 changes, and Faraday's law gives an emf in coil 2. This effect is called mutual inductance.
Self inductance links a coil's own current to its own flux. Mutual inductance links the current in one coil to the flux in a different coil.
Definition and formula
The flux linked with coil 2 is proportional to the current in coil 1:
N₂ φ₂ = M I₁
The constant M is the coefficient of mutual inductance. N₂ is the number of turns of coil 2, and φ₂ is the flux through one turn of coil 2. Applying Faraday's law to this relation gives the induced emf:
e₂ = −N₂ dφ₂/dt = −M dI₁/dt
The minus sign is Lenz's law. The induced emf opposes the change in I₁.
- The SI unit of M is the henry (H). One henry means 1 V of emf is induced when the current in the other coil changes at 1 A/s.
- The dimensions of M are the same as those of L, which is [M L² T⁻² A⁻²].
- M depends only on geometry and the medium. The relevant geometry is the shape and size of the coils, the number of turns, how far apart the coils are, and how they are oriented. A core of high permeability raises M.
- M is symmetric. The emf induced in coil 1 by a changing current in coil 2 uses the same constant, so M₁₂ = M₂₁ = M. This is why we write a single symbol.
Two coaxial solenoids
The standard NEET case is a long solenoid (coil 1) with a second coil (coil 2) wound tightly around its middle.
- Coil 1 has N₁ turns, length l and cross-section area A. The current I₁ gives a field B = μ₀ N₁ I₁ / l inside it.
- All of this flux passes through each turn of coil 2, so φ₂ = B A = μ₀ N₁ I₁ A / l.
- The flux linked with coil 2 is N₂ φ₂ = μ₀ N₁ N₂ A I₁ / l.
- Comparing with N₂ φ₂ = M I₁ gives:
M = μ₀ N₁ N₂ A / l
If a core of relative permeability μᵣ fills the solenoid, replace μ₀ with μ₀ μᵣ.
You can check the result in the other direction. Put the current I₂ in coil 2. The field of coil 2 is not confined to the area A, so the calculation is harder. The reciprocity M₁₂ = M₂₁ lets you pick whichever direction is easier. Always use the one where the field is simple.
Coupling coefficient
Not all the flux of one coil reaches the other. The coupling coefficient k measures the fraction that does:
M = k √(L₁ L₂), with 0 ≤ k ≤ 1
| Value of k | Meaning |
|---|---|
| 0 | No shared flux, for example coils with perpendicular axes |
| Between 0 and 1 | Partial coupling, for example coils placed side by side in air |
| 1 | All flux of one coil links the other, the ideal case for a transformer |
For the two solenoids above, L₁ = μ₀ N₁² A / l and L₂ = μ₀ N₂² A / l if both have the same A and l. Then √(L₁ L₂) = μ₀ N₁ N₂ A / l, which equals M. So k = 1 for this ideal arrangement.
Coils in series
When two coupled coils are connected in series, the equivalent inductance depends on how their fluxes combine.
| Connection | Equivalent inductance |
|---|---|
| Fluxes aid each other | L = L₁ + L₂ + 2M |
| Fluxes oppose each other | L = L₁ + L₂ − 2M |
| No coupling (M = 0) | L = L₁ + L₂ |
Worked example
Coil 1 is a solenoid with 1000 turns, length 0.5 m and cross-section 4 × 10⁻⁴ m². Coil 2 has 200 turns and is wound over the middle of coil 1. The current in coil 1 changes at 50 A/s. Find M and the emf in coil 2.
import math
mu0 = 4 * math.pi * 1e-7 # permeability of free space, H/m
N1 = 1000 # turns in the solenoid
N2 = 200 # turns in the outer coil
A = 4e-4 # cross-section area in m^2
l = 0.5 # solenoid length in m
dI_dt = 50.0 # rate of change of current in A/s
M = mu0 * N1 * N2 * A / l
emf2 = M * dI_dt # magnitude of the induced emf
print(f"M = {M * 1000:.3f} mH")
print(f"emf in coil 2 = {emf2 * 1000:.2f} mV")Running this prints M = 0.201 mH and an emf of 10.05 mV. The sign of the emf is set by Lenz's law. The induced current in coil 2 flows so that its own field opposes the change in the field of coil 1.
Common errors
- Using N₁ φ₂ or N₂ φ₁. The flux linked with coil 2 is N₂ times the flux per turn through coil 2. Match the turns to the coil where the emf appears.
- Using the wrong area. In M = μ₀ N₁ N₂ A / l, A is the cross-section of the inner solenoid, because that is the only region holding the field. The outer coil may be larger, but its extra area adds no flux.
- Forgetting that M is not a function of current. M does not change when I₁ changes. Only dI₁/dt matters for the emf.
- Mixing up k and M. k has no unit, and M is in henry. M = k √(L₁ L₂) only holds with the same units for all three.
- Treating the minus sign as a reduction in magnitude. The sign only gives the direction. For numerical answers, use |e₂| = M |dI₁/dt|.
- Ignoring series connection type. The ±2M term changes the answer. Read the question for how the windings are connected.
Where it leads
A transformer has two coils on a common iron core, so k is close to 1. The emf in the secondary coil is e₂ = −M dI₁/dt, and the turns ratio N₂/N₁ sets the voltage ratio. Mutual inductance also explains wireless chargers and induction stoves, and it is a source of unwanted interference between neighbouring circuits.
Exercise
The current in coil 1 changes from 0 to 4 A in 0.1 s, and an average emf of 2 V is induced in coil 2. Find the mutual inductance of the pair.
Show answer
The rate of change is 4 A / 0.1 s = 40 A/s. From |e₂| = M |dI₁/dt|, M = 2 / 40 = 0.05 H.
Exercise
Two coils have self inductances 4 mH and 9 mH, and a coupling coefficient k = 0.5. Find M, and find the equivalent inductance when they are connected in series with their fluxes aiding.
Show answer
M = k √(L₁ L₂) = 0.5 × √(4 × 9) mH = 0.5 × 6 mH = 3 mH. For aiding fluxes, L = L₁ + L₂ + 2M = 4 + 9 + 6 = 19 mH.