Sub topic 10
Using the Equivalent to Analyze Different Loads
This chapter assumes you can already find Vth and Rth for a two-terminal network (open-circuit voltage, then Rth with independent sources turned off) and that you know Ohm's law, the voltage divider, and the current divider. The goal here is the payoff: solve the network once, then reuse the result for any load.
Why one equivalent replaces many analyses
Suppose a sensor, a battery pack, or a power supply feeds a load that changes. It might be a resistor you are still choosing, a motor that draws different currents, or several candidate loads on a bench. Re-solving the whole network for each load with node or mesh analysis repeats work that does not depend on the load.
The Thévenin equivalent separates the two parts:
- The network supplies a fixed Vth and a fixed Rth. These never change as long as the network itself is unchanged.
- The load is the only part that varies.
Once you have Vth and Rth, each new load costs a single series-circuit calculation.
The load equations
Connect a load resistance RL to the Thévenin equivalent. The circuit is a single loop, so:
- Load current: IL = Vth / (Rth + RL)
- Load voltage: VL = Vth · RL / (Rth + RL), which is a voltage divider between Rth and RL
- Load power: PL = IL² · RL = VL² / RL
With the Norton form (IN in parallel with Rth), the same load gets a current divider:
- IL = IN · Rth / (Rth + RL)
- VL = IL · RL
Both forms give identical answers because IN = Vth / Rth. Use whichever form your network gave you more directly.
Two limits are useful as sanity checks:
- RL → ∞ (open circuit): IL = 0 and VL = Vth.
- RL = 0 (short circuit): VL = 0 and IL = Vth / Rth = IN.
Every real load result must fall between these two extremes.
Worked example
Use the circuit from the spine: a 12 V source in series with R1 = 4 Ω, and R2 = 6 Ω across terminals a-b. You find:
- Vth = 12 · 6 / (4 + 6) = 7.2 V
- Rth = 4 ∥ 6 = 2.4 Ω
- IN = 7.2 / 2.4 = 3 A
The following program connects four loads to the equivalent.
v_th = 7.2
r_th = 2.4
for r_load in (1.2, 2.4, 3.6, 7.2):
i = v_th / (r_th + r_load)
p = i ** 2 * r_load
print(f"RL = {r_load:.1f} ohm I = {i:.3f} A P = {p:.3f} W")
# RL = 1.2 ohm I = 2.000 A P = 4.800 W
# RL = 2.4 ohm I = 1.500 A P = 5.400 W
# RL = 3.6 ohm I = 1.200 A P = 5.184 W
# RL = 7.2 ohm I = 0.750 A P = 4.050 WCheck the RL = 3.6 Ω row by hand. The total resistance is 2.4 + 3.6 = 6 Ω, so I = 7.2 / 6 = 1.2 A. The load voltage is 1.2 · 3.6 = 4.32 V, and the power is 1.2² · 3.6 = 5.184 W. This matches the output.
Now confirm the equivalent against the original circuit for one load, RL = 3.6 Ω. With RL connected across a-b, R2 and RL are in parallel: 6 ∥ 3.6 = 2.25 Ω. The total resistance seen by the source is 4 + 2.25 = 6.25 Ω, so the source current is 12 / 6.25 = 1.92 A. The voltage at a is 1.92 · 2.25 = 4.32 V. This equals the equivalent's VL, so the load cannot tell the two circuits apart.
Observing the trend in the table
The table below collects the results, and adds the load voltage.
| RL (Ω) | IL (A) | VL (V) | PL (W) |
|---|---|---|---|
| 1.2 | 2.000 | 2.40 | 4.800 |
| 2.4 | 1.500 | 3.60 | 5.400 |
| 3.6 | 1.200 | 4.32 | 5.184 |
| 7.2 | 0.750 | 5.40 | 4.050 |
As RL rises, the current falls and the voltage rises. Power rises, peaks near RL = Rth, then falls. The next chapter explains that peak. For now, use the table to see that a single pair (Vth, Rth) predicts every row.
A procedure you can follow
- Mark the two terminals and identify the load. Remove it.
- Find Vth (open-circuit voltage) and Rth (sources off, or test source, or Voc / Isc).
- Draw the equivalent with the load reattached as a single loop.
- Compute IL, VL, and PL with the formulas above.
- Check against the limits: |VL| ≤ |Vth| and |IL| ≤ |IN| for any passive resistive load.
Loads that are not simple resistors
The formulas above assume a fixed resistor. Other loads need a little more thought.
- Several resistors. Combine them into one equivalent RL first, using series and parallel rules. Then apply the formulas. To find the current in one branch, use the load voltage VL and Ohm's law on that branch.
- A load with its own source. Treat it as a battery in series with a resistance. If the load is a battery Eb in series with Rb, the current is IL = (Vth − Eb) / (Rth + Rb), with the sign set by the polarity you choose. A negative result means current flows into the network, as in charging.
- A nonlinear load such as a diode. The network side is still replaced by Vth and Rth, but the load equation is not Ohm's law. You solve Vth − IL · Rth = VL together with the diode's current-voltage relationship. A graph of the two curves (a load line) or iteration gives the operating point. The equivalent remains valid because only the network side must be linear.
Common errors
- Using the wrong resistance in the divider. In VL = Vth · RL / (Rth + RL), the denominator uses Rth, not the original circuit's resistors.
- Leaving the load in when finding Vth or Rth. The load must be removed first. If it stays in, the open-circuit voltage and the resistance both come out wrong.
- Computing power inside the equivalent and assuming it matches the original. The load power matches. The power dissipated inside the equivalent does not. Rth dissipates IL² · Rth, which is generally not what the original network's internal resistors and source dissipate. Never use the equivalent to compute efficiency or internal heating of the original circuit.
- Mixing Thévenin and Norton formulas. If you use IN, use the current divider with Rth in parallel. If you use Vth, use the voltage divider with Rth in series.
- Forgetting polarity. Choose the reference direction of Vth to match the sign you found at the terminals. Otherwise the load current comes out with the wrong sign.
Checking the no-load case numerically
The no-load figures in the warning are easy to verify. With the load open in the original circuit, the current through R1 and R2 is 12 / 10 = 1.2 A, so the dissipation is 1.2 · 12 = 14.4 W. In the equivalent with an open load, the current is zero. The load sees the same 7.2 V and 0 A in both circuits, but the internal power differs.
Exercise
A network has Vth = 9 V and Rth = 3 Ω. Find the load current, load voltage, and load power for RL = 6 Ω. Then find the Norton current and use the current divider to confirm the load current.
Show answer
The total resistance is 3 + 6 = 9 Ω, so IL = 9 / 9 = 1 A. The load voltage is VL = 1 · 6 = 6 V and the power is PL = 1² · 6 = 6 W. The Norton current is IN = 9 / 3 = 3 A. The current divider gives IL = 3 · 3 / (3 + 6) = 1 A, which matches.
Exercise
The same equivalent (Vth = 9 V, Rth = 3 Ω) feeds a 6 V battery in series with 1 Ω, with the battery's positive terminal connected to the positive terminal of the equivalent. What is the current, and is the battery charging or discharging?
Show answer
IL = (9 − 6) / (3 + 1) = 0.75 A. The current flows out of the positive terminal of the equivalent and into the positive terminal of the battery, so the battery is charging.