Sub topic 4
Thévenin's theorem: one source and one resistor
This chapter assumes you can apply Ohm's law, Kirchhoff's laws, series and parallel reduction, and the voltage divider. It also assumes you know what independent and dependent sources are. Later chapters cover the methods for finding Vth and Rth in detail. Here the goal is to state the theorem, see why it works, and use it on a complete example.
The statement
Thévenin's theorem says this. Take any linear two-terminal network. It may contain independent sources, dependent sources and resistors. Connect it to any external circuit. The external circuit cannot tell the difference if you replace the network with two parts in series:
- An ideal voltage source Vth, the Thévenin voltage.
- A resistor Rth, the Thévenin resistance.
Both values are measured at the two terminals, which we call a and b. The external circuit is the load. It can be a single resistor or a large network.
The equivalence applies at the terminals only. The current and voltage at a and b are the same for every load. The voltages and currents inside the original network are not preserved.
Why it works
The proof rests on linearity. In a linear circuit, every voltage and current is a sum of terms. Each term is proportional to one source. This is the superposition principle.
Suppose you connect a load that draws current I from the network. The terminal voltage V then has two contributions:
- The contribution from the network's own sources. This is the voltage you would see with the load removed, which is the open-circuit voltage Voc.
- The contribution from the load current. With all independent sources off, the network acts as a resistance, so this term is proportional to I and has the form −Rth·I.
Adding them gives the terminal relationship:
V = Voc − Rth · I
This is the equation of a voltage source Vth = Voc in series with Rth. Any linear network has a straight-line V–I characteristic at its terminals, and a straight line is fixed by two numbers. That is why two parameters are enough.
The procedure
- Identify the two terminals and remove the load. The terminals are now open.
- Compute Vth as the open-circuit voltage between a and b.
- Compute Rth. Turn off all independent sources. Replace voltage sources with short circuits and current sources with open circuits. Then find the resistance seen looking into a and b.
- Draw Vth in series with Rth and reconnect the load.
The sign of Vth matters. If terminal a is more positive than b with the load removed, draw the source with its positive side toward a.
Worked example
A 12 V source is in series with R1 = 4 Ω. A resistor R2 = 6 Ω is connected from the junction of R1 and R2 to ground. The load is connected across R2, so terminals a and b are the two ends of R2.
Step 1. Remove the load. Terminals a and b are open.
Step 2. With no load, current flows only through R1 and R2 in series. The voltage divider gives the open-circuit voltage across R2:
Vth = 12 × 6 / (4 + 6) = 7.2 V
Step 3. Turn off the 12 V source by replacing it with a short circuit. Looking into the terminals, R1 and R2 are now in parallel:
Rth = (4 × 6) / (4 + 6) = 2.4 Ω
Step 4. The equivalent is a 7.2 V source in series with 2.4 Ω. The following script repeats the calculation. It also computes the Norton current, which equals the short-circuit current. Chapter on Norton's theorem covers that form.
vs = 12.0 # source voltage in volts
r1 = 4.0 # series resistor in ohms
r2 = 6.0 # resistor across terminals a-b in ohms
def parallel(a, b):
return a * b / (a + b)
v_th = vs * r2 / (r1 + r2) # open-circuit voltage at a-b (voltage divider)
r_th = parallel(r1, r2) # source off (shorted): R1 in parallel with R2
i_n = v_th / r_th # Norton current
print(f"Vth = {v_th:.2f} V, Rth = {r_th:.2f} ohm, IN = {i_n:.2f} A")
# Vth = 7.20 V, Rth = 2.40 ohm, IN = 3.00 AThe value IN = 3 A matches a direct check. If you short a to b, all 12 V falls across R1, so the current is 12 / 4 = 3 A.
Checking the equivalent with a load
Connect a 3.6 Ω load. In the equivalent circuit the current is 7.2 / (2.4 + 3.6) = 1.2 A, and the load voltage is 1.2 × 3.6 = 4.32 V.
Check this in the original circuit. The load is in parallel with R2: (6 × 3.6) / (6 + 3.6) = 2.25 Ω. The divider gives the voltage across the parallel pair: 12 × 2.25 / (4 + 2.25) = 4.32 V. The load current is 4.32 / 3.6 = 1.2 A. Both circuits agree.
A SPICE simulator confirms the hand values. The .op analysis gives the open-circuit voltage at node a. The .tf analysis reports the output resistance at that node, which is Rth.
* Thevenin check for the 12 V, 4 ohm, 6 ohm circuit
V1 in 0 DC 12
R1 in a 4
R2 a 0 6
.op
.tf v(a) V1
.endExpect v(a) = 7.2 V and an output resistance of 2.4 Ω.
Edge cases and common errors
- Wrong terminals. Different terminal pairs on the same network give different equivalents. Always state which two nodes you mean.
- Leaving the load in. Vth is the voltage with the load removed. If the load stays connected, you compute the loaded voltage, which is a different quantity.
- Resistors in series with a current source. When you turn off a current source, it becomes an open circuit. A resistor in series with that source then carries no current and does not contribute to Rth through that branch.
- Resistors across a voltage source. A resistor directly across an ideal voltage source disappears when the source is shorted. It does not affect Rth, though it may affect Vth.
- Ideal sources. An ideal voltage source in parallel with the terminals gives Rth = 0. An ideal current source in series with the terminals gives an open circuit and no finite Rth, so only the Norton form exists in that case.
- Zero Vth. A network with no independent sources has Vth = 0. It reduces to a resistor, or to a resistor-like element if dependent sources are present.
- Nonlinear parts. The theorem fails if the network contains a diode, transistor in a nonlinear region, or any element whose V–I curve is not a straight line. The load may be nonlinear, because the load is not part of the network being replaced.
Summary of the key relationships
| Quantity | How to find it | Example value |
|---|---|---|
| Vth | Open-circuit voltage at a-b | 7.2 V |
| Rth | Resistance at a-b with independent sources off | 2.4 Ω |
| Load current | Vth / (Rth + RL) | 1.2 A at RL = 3.6 Ω |
| Load voltage | Vth × RL / (Rth + RL) | 4.32 V at RL = 3.6 Ω |
Exercise
A 24 V source is in series with R1 = 12 Ω. A 6 Ω resistor R2 connects from the far end of R1 to ground. Terminals a and b are across R2. Find Vth and Rth, then find the current in a 10 Ω load connected across a-b.
Show answer
With the load removed, the divider gives Vth = 24 × 6 / (12 + 6) = 8 V. With the source shorted, R1 and R2 are in parallel, so Rth = 12 × 6 / 18 = 4 Ω. The load current is 8 / (4 + 10) ≈ 0.571 A.
Exercise
Why does the theorem allow a nonlinear load but not a nonlinear element inside the network being replaced?
Show answer
The proof uses superposition, which holds only for linear elements, to show that the terminal relationship is a straight line V = Voc − Rth·I. The load is attached after the equivalent is formed, so any load that has a defined V–I curve can be solved against that straight line. A nonlinear element inside the network makes the terminal V–I curve non-straight, so no single Vth and Rth can describe it.