Sub topic 16
Measuring Vth and Rth on real circuits
This chapter assumes you can calculate Vth and Rth on paper, and that you know how a voltage divider behaves. It covers getting the same two numbers from a physical circuit with a multimeter, a resistor box, or an oscilloscope. You can't switch off a real source or probe inside a sealed box, and every instrument disturbs the circuit it measures. The Thévenin model is the tool that lets you correct for that disturbance.
What you can and cannot do on a bench
The paper method turns off independent sources and reduces resistors. That is often impossible on hardware. The source may be a battery, a sensor, or an amplifier output whose internals you can't see. The measurable quantities are the voltage and current at the two terminals. Every method below uses only those.
Each method rests on the fact that a linear network behaves at its terminals like Vth in series with Rth. Any pair of terminal measurements under different loads therefore gives two equations in two unknowns.
| Method | What you measure | Result | Main error source |
|---|---|---|---|
| Open-circuit voltage | Voltage with nothing connected | Vth | Voltmeter input resistance |
| Short-circuit current | Current through a short | Isc, then Rth = Voc/Isc | Ammeter resistance, risk of damage |
| Half-voltage | Load resistance that halves the voltage | Rth = RL | Resistor-box tolerance |
| Two-load | Voltage under two known loads | Vth and Rth | Noise when the loads are badly chosen |
| Ohmmeter, sources off | Resistance at the terminals | Rth | Only valid if sources can be safely removed |
Measuring Vth
Connect a voltmeter across the terminals with the load removed. The meter reads Vth only if it draws negligible current. A real meter has an input resistance Rm, typically 10 MΩ for a digital multimeter. The meter and Rth form a voltage divider:
Vmeas = Vth × Rm / (Rm + Rth)
When Rth is a few ohms the error is negligible. When Rth is 1 MΩ, as in a high-impedance sensor, the reading is about 9% low. The code below shows the error and the correction. The correction needs an estimate of Rth, which you can get from the methods later in this chapter.
v_th = 5.0 # true open-circuit voltage in volts
r_th = 1.0e6 # source resistance in ohms
r_m = 10.0e6 # voltmeter input resistance in ohms
v_meas = v_th * r_m / (r_m + r_th)
error_pct = (v_meas - v_th) / v_th * 100
v_corrected = v_meas * (r_m + r_th) / r_m
print(f"Reading = {v_meas:.3f} V, error = {error_pct:.2f} %")
print(f"Corrected Vth = {v_corrected:.3f} V")
# Reading = 4.545 V, error = -9.09 %
# Corrected Vth = 5.000 VMeasuring Rth
Short-circuit current
If Voc is the open-circuit voltage and Isc is the current through a short, then Rth = Voc / Isc. This follows directly from the model: with the terminals shorted, the whole of Vth drops across Rth.
The method has two problems on real hardware.
- A short can destroy a source that can't supply the current. A bench supply may trip, a small battery may overheat, and an amplifier output stage may fail.
- An ammeter is a small resistor Ra in series with the short. The meter reads Vth / (Rth + Ra), not Vth / Rth.
For the 12 V, 4 Ω, 6 Ω circuit from earlier chapters, Rth = 2.4 Ω and the true Isc is 3 A. A meter with 1 Ω burden resistance reads 7.2 / 3.4 = 2.12 A, which is 29% low. The Rth you calculate from it would be 3.4 Ω.
Half-voltage method
Connect an adjustable resistor (a decade box or potentiometer) across the terminals and adjust it until the voltmeter reads Vth/2. At that point the load and Rth form an equal divider, so RL = Rth. Remove the resistor and measure its value with an ohmmeter. The method avoids shorting the source, and it needs only one voltmeter and one variable resistor.
Two-load method
When you can't conveniently tune a resistor, use two known loads R1 and R2 and record the terminal voltages V1 and V2. The load currents are I1 = V1/R1 and I2 = V2/R2. The same Vth appears in both loaded circuits:
V1 + I1 × Rth = V2 + I2 × Rth
Solving gives:
- Rth = (V1 − V2) / (I2 − I1)
- Vth = V1 + I1 × Rth
def thevenin_from_two_loads(r1, v1, r2, v2):
i1 = v1 / r1
i2 = v2 / r2
r_th = (v1 - v2) / (i2 - i1)
v_th = v1 + i1 * r_th
return v_th, r_th
# Simulated readings from the 7.2 V, 2.4 ohm source with 10 and 2.4 ohm loads
v1 = 7.2 * 10.0 / (2.4 + 10.0)
v2 = 7.2 * 2.4 / (2.4 + 2.4)
v_th, r_th = thevenin_from_two_loads(10.0, v1, 2.4, v2)
print(f"Vth = {v_th:.2f} V, Rth = {r_th:.2f} ohm")
# Vth = 7.20 V, Rth = 2.40 ohmChoose loads of similar size to Rth. If both loads are much larger than Rth, then V1 and V2 are almost equal. Their difference is then dominated by meter resolution and noise, and the computed Rth is unreliable. A good rule is to pick one load near Rth and the other about three to ten times larger.
This method also covers the case where Voc is hard to read. A single loaded measurement plus a known Voc gives Rth = RL × (Voc / VL − 1). For an AA cell with Voc = 1.60 V that reads 1.50 V across a 10 Ω load, Rth = 10 × (1.60 / 1.50 − 1) = 0.667 Ω. This is the battery's internal resistance.
Ohmmeter method
If every independent source can be switched off or removed safely, measure the resistance between the terminals directly. Replace each voltage source with a short and each current source with an open circuit, as in the paper method. Two conditions apply.
- Never connect an ohmmeter to a powered circuit. The meter injects its own test current and the result is meaningless, and it can damage the meter.
- The method does not work with dependent sources or with semiconductors that conduct at the meter's test voltage. A non-zero source such as a transistor bias network changes the answer.
Choosing a method
AC and dynamic circuits
On an AC source, Zth is complex, so the voltage-halving method gives only the magnitude when the load is resistive. Use an oscilloscope and compare amplitudes at one frequency. Remember that the scope probe adds its own input resistance and capacitance, usually 1 MΩ with 10 to 15 pF for a passive 10× probe. At high frequencies that capacitance lowers the apparent impedance and shifts the phase.
Practical checks
- Repeat the measurement with a third load. If the predicted voltage differs from the measured voltage by more than your instrument tolerance, the source isn't behaving linearly at that operating point.
- Measure at the operating current. A diode, a transistor, or a battery near the end of its charge has a Thévenin model that depends on the current. The equivalent is valid only near the point where you measured it.
- Let the source settle. A battery or a thermally drifting sensor changes Voc during the test, which corrupts the two-load calculation.
- Record the meter range. Digital meters change input resistance on some ranges, particularly the low-voltage ones.
Exercise
A sensor reads Voc = 9.0 V on a 10 MΩ voltmeter. You then connect a 100 Ω resistor across it and the voltage falls to 7.5 V. (a) Find Rth. (b) Find the short-circuit current this implies. (c) State why you would not measure that current directly.
Show answer
(a) Rth = RL × (Voc / VL − 1) = 100 × (9.0 / 7.5 − 1) = 20 Ω. The 10 MΩ meter loading is negligible against 20 Ω. (b) Isc = Voc / Rth = 9.0 / 20 = 0.45 A. (c) A short could overload the sensor, and an ammeter's own resistance would also reduce the reading, so the load method is safer and more accurate.
Exercise
A high-impedance source has Vth = 2.00 V and Rth = 500 kΩ. A voltmeter with Rm = 10 MΩ measures it. What does the meter read, and what is the percentage error?
Show answer
Vmeas = 2.00 × 10 / (10 + 0.5) = 1.905 V. The error is (1.905 − 2.00) / 2.00 ≈ −4.76%.