Sub topic 1
Terminals, Ports and the Load You Remove
Prerequisites
This chapter assumes you can already do the following:
- Apply Ohm's law and Kirchhoff's voltage and current laws.
- Combine series and parallel resistors.
- Use voltage and current dividers.
- Recognize independent and dependent sources.
You do not need node-voltage or mesh-current analysis yet. Later chapters use them to find equivalents.
Why start with terminals
Thévenin's and Norton's theorems replace a large circuit with a small one. Before you can do that, you have to say exactly which part you are replacing and what it connects to. Most mistakes in this topic come from skipping that decision.
This chapter covers three things:
- How to identify the two terminals of a network.
- What a port is and why it matters.
- How to split a circuit into the part you simplify and the load you remove.
Two-terminal networks
A two-terminal network is any collection of sources and resistors that connects to the rest of the circuit through exactly two nodes. These two nodes are the terminals. Everything inside the network is hidden from the outside. The outside sees only the voltage between the terminals and the current that flows through them.
By convention the terminals are labeled a and b. The terminal voltage is Vab, the voltage at a relative to b. The terminal current I is the current that leaves the network through a and returns through b.
Two points about the terminals:
- They are nodes, not components. You mark them on the wire, usually where a component such as a resistor was cut away or where a pair of open dots is drawn.
- Their polarity is a choice. Pick a and b, then keep that choice for every later step. Switching them flips the sign of Vab.
What a port is
A port is a pair of terminals where the current entering one terminal always equals the current leaving the other. If that holds, the network can be described by just two quantities, Vab and I.
The port condition fails when something else connects to the network, such as a third wire, a shared ground path, or a coupling to another part of the circuit. In that case current can enter at a and leave somewhere other than b. A Thévenin or Norton equivalent describes only the port, so it cannot represent such a connection.
In practice you meet this when the load and the network share a ground. If both a and b are connected to the same ground node elsewhere, check that no current can take that path around the load.
The load you remove
The load is whatever you connect across the terminals and want to analyze. It might be a resistor, a lamp, an amplifier input, or a whole second circuit. To find the equivalent, you detach the load. The terminals are then open, and the network is by itself.
The method has three steps:
- Choose the element or branch you want to analyze, and call it the load.
- Remove it and mark the two nodes it was attached to as a and b.
- Treat everything that remains as the two-terminal network to simplify.
The equivalent is a property of the network and its terminals, not of the load. You can change the load afterward and reuse the same equivalent. This is the main reason the technique is useful.
The diagram below shows the split.
A running example
The examples in later chapters use one circuit. A 12 V source is in series with a 4 ohm resistor R1. A 6 ohm resistor R2 is connected from the node after R1 down to the return wire of the source. The terminals a and b are placed across R2. The load, when there is one, connects between a and b in parallel with R2.
In this circuit:
| Part | Role |
|---|---|
| 12 V source | Inside the network |
| R1 = 4 ohm | Inside the network |
| R2 = 6 ohm | Inside the network, because it stays when the load is removed |
| Load RL | Removed; it connects across a and b |
Note that R2 is part of the network even though it sits directly across the terminals. Only the load is removed. A resistor that belongs to the circuit you are simplifying stays.
The direct way to analyze the circuit is to put RL in parallel with R2, then apply a voltage divider with R1. The following program does that for three loads.
vs = 12.0 # source voltage in volts
r1 = 4.0 # series resistor in ohms
r2 = 6.0 # resistor across terminals a-b in ohms
def parallel(a, b):
return a * b / (a + b)
for r_load in (3.0, 6.0, 12.0):
r_ab = parallel(r2, r_load) # R2 and the load share a and b
v_ab = vs * r_ab / (r1 + r_ab) # voltage divider with R1
i_load = v_ab / r_load
print(f"RL = {r_load:4.1f} ohm Vab = {v_ab:.3f} V I = {i_load:.3f} A")
# RL = 3.0 ohm Vab = 4.000 V I = 1.333 A
# RL = 6.0 ohm Vab = 5.143 V I = 0.857 A
# RL = 12.0 ohm Vab = 6.000 V I = 0.500 AEach new load forces you to redo the whole calculation. The equivalent, built from the open terminals, replaces that repeated work. A later chapter shows that the same circuit reduces to 7.2 V in series with 2.4 ohm. That is the circuit used throughout the rest of the tutorial.
Choosing where to cut
You can often place the terminals in more than one way, and the choice affects how easy the problem is. A good choice follows from what you want to know.
- If you want the current or power in one resistor, make that resistor the load.
- If you want to see how a circuit behaves for many values of one component, make that component the load.
- If a component's value is unknown or varies, such as a potentiometer, a sensor, or a speaker, make it the load.
When the question is about a single element, the terminals are the two nodes that element connects to.
What can sit inside the network
The equivalent is guaranteed to exist only if the network is linear. For now, treat that as a rule about what is allowed inside:
- Independent voltage and current sources.
- Linear resistors.
- Dependent sources whose output is proportional to a voltage or current.
Diodes, transistors modeled by their full curves, and other nonlinear parts break the guarantee. The next chapter explains why. Nonlinear parts are fine in the load, because the load is removed before you build the equivalent.
Dependent sources need one extra check. The variable that controls a dependent source must be inside the network, not in the load. If the controlling voltage or current is in the load, removing the load removes the control. In that case, choose different terminals so the controlling element stays on the network side.
Common mistakes
- Removing too much. Taking out a resistor that belongs to the network changes the circuit you are simplifying. Remove only the load.
- Removing too little. Leaving part of the load connected means the terminals are not open, and later results will be wrong.
- Losing the polarity. Without a marked a and b, a negative Vth is hard to interpret. Mark them first.
- Cutting a dependent source's control. See the check above.
- Ignoring extra connections. A shared ground can violate the port condition. Check that all current at a returns through b.
Summary
A two-terminal network meets the outside world at nodes a and b. When it forms a port, its behavior is fully described by Vab and I. The load is the part you detach, and everything else is the network. In the running example, R1, R2 and the 12 V source form the network, and RL is the load. The next chapter explains why a linear network of this kind can always be replaced by one source and one resistor.
Exercise
A 12 V source is in series with R1 = 4 ohm. A 6 ohm resistor R2 connects from the far end of R1 to the source return. A load RL = 4 ohm is connected across R2. (a) Which elements form the network, and which is the load? (b) Find Vab and the load current with RL in place.
Show answer
(a) The 12 V source, R1 and R2 form the network, because they remain when the load is removed. RL is the load. (b) R2 in parallel with RL is 6 x 4 / 10 = 2.4 ohm. The divider gives Vab = 12 x 2.4 / (4 + 2.4) = 4.5 V. The load current is 4.5 / 4 = 1.125 A.
Exercise
A network contains a current-controlled current source whose controlling current flows in the resistor you plan to use as the load. Why is that choice of terminals a problem, and what should you do?
Show answer
Removing the load removes the controlling current, so the dependent source is left without its control and the remaining network no longer describes the original circuit. Choose terminals so the controlling resistor stays in the network, and make a different element the load.