Sub topic 8
Converting between Thévenin and Norton forms
This chapter assumes you can find Vth and Rth for a two-terminal network and that you know Ohm's law and parallel resistance. It covers how to convert one equivalent into the other, why the conversion works, and what the two forms do not share.
The two forms describe the same terminal behavior
A Thévenin equivalent is a voltage source Vth in series with Rth. A Norton equivalent is a current source IN in parallel with RN. If both replace the same network, a load on terminals a-b must see the same voltage and current in each. That requirement fixes the conversion.
Take the Thévenin form and short terminals a-b. The only thing limiting current is Rth, so the short-circuit current is Vth / Rth. Take the Norton form and short a-b. All of IN flows through the short, so the short-circuit current is IN. The two short-circuit currents must be equal:
IN = Vth / Rth
With the terminals open, the Thévenin form shows Vth. In the Norton form, all of IN flows through RN, so the open-circuit voltage is IN × RN. Setting these equal gives Vth = IN × RN. Both conditions hold at once only if RN = Rth. This is why the resistance is the same number in both forms.
| Quantity | Thévenin form | Norton form |
|---|---|---|
| Source | Voltage source Vth | Current source IN |
| Resistor placement | In series with the source | In parallel with the source |
| Open-circuit voltage | Vth | IN × Rth |
| Short-circuit current | Vth / Rth | IN |
| Resistance | Rth | RN = Rth |
Getting the direction right
Most conversion errors come from orientation, not arithmetic. The arrow of the current source must point toward the terminal that the positive end of the voltage source points toward. Check it with the short-circuit test: with a-b shorted, the Thévenin form drives current out of terminal a through the short. The Norton arrow must drive the same current the same way.
If the Thévenin source has its positive end at terminal a, the Norton arrow points toward a. If the polarity is reversed, the arrow is reversed too. A wrong sign here gives a load voltage with the wrong polarity, and the magnitude will still look plausible.
Worked example: the running circuit
The earlier example gave Vth = 7.2 V and Rth = 2.4 Ω. The Norton form follows directly:
- IN = 7.2 V / 2.4 Ω = 3 A
- RN = 2.4 Ω
This matches the short-circuit current of the original circuit. A 12 V source in series with 4 Ω, with terminals a-b shorted, carries 12 V / 4 Ω = 3 A. Rth = Voc / Isc = 7.2 / 3 = 2.4 Ω confirms the resistance as well.
A 3.6 Ω load shows that both forms predict the same result:
- Thévenin: I = 7.2 / (2.4 + 3.6) = 1.2 A, so V = 1.2 × 3.6 = 4.32 V.
- Norton: the current divider gives I = 3 × 2.4 / (2.4 + 3.6) = 1.2 A, so V = 4.32 V.
Using conversion to reduce a circuit
Conversion is most useful when several sources feed the same node. Voltage sources with series resistors cannot be combined directly when they are in parallel. Current sources in parallel can: their currents add, and their resistances combine as parallel resistors.
Suppose two branches connect to node a, each to ground. Branch 1 is 10 V in series with 5 Ω. Branch 2 is 20 V in series with 20 Ω.
- Convert branch 1: IN1 = 10 / 5 = 2 A in parallel with 5 Ω.
- Convert branch 2: IN2 = 20 / 20 = 1 A in parallel with 20 Ω.
- Combine: the currents add to 3 A, and 5 Ω in parallel with 20 Ω gives 4 Ω.
- Convert back: Vth = 3 A × 4 Ω = 12 V, with Rth = 4 Ω.
A 4 Ω load then sees 12 × 4 / (4 + 4) = 6 V.
The following script automates both conversions and this reduction. It uses only the standard library.
def thevenin_to_norton(v_th, r_th):
return v_th / r_th, r_th
def norton_to_thevenin(i_n, r_n):
return i_n * r_n, r_n
# Running example from the earlier chapters
i_n, r_n = thevenin_to_norton(7.2, 2.4)
print(f"IN = {i_n:.2f} A, RN = {r_n:.2f} ohm")
# Two voltage-source branches feeding the same node
branches = [(10.0, 5.0), (20.0, 20.0)] # (voltage, series resistance)
total_i = 0.0
total_g = 0.0 # conductance in siemens
for v, r in branches:
i, _ = thevenin_to_norton(v, r)
total_i += i
total_g += 1.0 / r
r_eq = 1.0 / total_g
v_th, r_th = norton_to_thevenin(total_i, r_eq)
print(f"Combined: IN = {total_i:.2f} A, Rth = {r_eq:.2f} ohm")
print(f"Thevenin: Vth = {v_th:.2f} V, Rth = {r_th:.2f} ohm")
r_load = 4.0
v_load = v_th * r_load / (r_th + r_load)
print(f"Load voltage at {r_load:.1f} ohm = {v_load:.2f} V")
# IN = 3.00 A, RN = 2.40 ohm
# Combined: IN = 3.00 A, Rth = 4.00 ohm
# Thevenin: Vth = 12.00 V, Rth = 4.00 ohm
# Load voltage at 4.0 ohm = 6.00 VAdding conductances instead of multiplying resistances scales to any number of branches. This is the same calculation as Millman's theorem.
What conversion does not preserve
The equivalence is a statement about terminals a-b only. Inside the equivalent, the two forms behave differently, and they differ from the original network too. Use the 7.2 V, 2.4 Ω, 3 A example:
| Condition at a-b | Thévenin form dissipates | Norton form dissipates |
|---|---|---|
| Open circuit | 0 W | 3² × 2.4 = 21.6 W |
| Short circuit | 7.2² / 2.4 = 21.6 W | 0 W |
An open Thévenin form has no current, so Rth dissipates nothing. An open Norton form pushes all 3 A through RN. A source or resistor power rating that you read off an equivalent therefore means nothing. Never use an equivalent to find the power dissipated inside the original network.
Edge cases
- Ideal voltage source (Rth = 0). IN = Vth / 0 is undefined, so there is no Norton form. A voltage source with no series resistance cannot be converted.
- Ideal current source (RN = ∞). Vth = IN × ∞ is undefined, so there is no Thévenin form.
- A resistor in parallel with a voltage source. It does not affect the terminal behavior seen across that source. Remove it before converting. The same is true of a resistor in series with a current source.
- Dependent sources. You may convert a dependent source with its resistor in the same way. The controlling variable must remain in the circuit and must not be lost in the conversion. If the controlling current flows in the resistor you convert away, that variable has disappeared. Keep that part of the circuit as it is, or switch to the test-source method.
Common errors
- Computing IN = Vth × Rth instead of Vth / Rth. A unit check catches this: volts divided by ohms gives amperes.
- Placing the Norton resistor in series. In the Norton form, it is always in parallel with the current source.
- Reversing the arrow relative to the polarity. Short the terminals and check the direction of the current.
- Adding voltages from parallel branches. Convert to current sources first, then add currents.
- Converting the source that includes the load. The load is never part of the equivalent.
Exercise
A Thévenin equivalent has Vth = 24 V and Rth = 8 Ω, with the positive end at terminal a. Give the Norton equivalent, including the arrow direction. Then find the current in a 16 Ω load using each form, and the power the load absorbs.
Show answer
IN = 24 / 8 = 3 A with RN = 8 Ω, and the arrow points toward terminal a. Thévenin: I = 24 / (8 + 16) = 1 A. Norton: the current divider gives I = 3 × 8 / (8 + 16) = 1 A. The load power is I² × RL = 1² × 16 = 16 W.
Exercise
A 5 mA current source with 2 kΩ in parallel feeds terminals a-b, with a 6 mA source and 3 kΩ in parallel on the same terminals, both with arrows toward a. Find the single Thévenin equivalent.
Show answer
The currents add: IN = 5 + 6 = 11 mA. The resistances combine in parallel: 2 kΩ || 3 kΩ = 6 / 5 = 1.2 kΩ. Then Vth = 11 mA × 1.2 kΩ = 13.2 V, with Rth = 1.2 kΩ and the positive end at terminal a.