Sub topic 14
Unknown Resistance from the Balance Length
This chapter assumes you know the Wheatstone bridge balance condition and the meter bridge layout from the previous two chapters. You should also be comfortable with resistance, length and series and parallel combinations. Here you turn a single reading, the balance length, into a value of an unknown resistance, and you learn how to choose and interpret that reading.
From the balance condition to X = R(100 - l)/l
A meter bridge is a Wheatstone bridge in which two of the four arms are the two parts of one uniform 100 cm wire. A known resistance R sits in the left gap and the unknown resistance X sits in the right gap. The jockey touches the wire at a point that is l cm from the left end. At the null point the galvanometer shows zero deflection.
The Wheatstone condition at balance is:
R / X = (resistance of the left wire part) / (resistance of the right wire part)
The wire is uniform, so its resistance is proportional to its length. The left part has length l and the right part has length (100 - l). The common factor (resistance per unit length) cancels:
R / X = l / (100 - l)
Solving for X gives the working formula:
X = R (100 - l) / l
Here l is always measured from the end of the wire nearest to R. This is the most common source of mistakes in this experiment.
What the formula tells you
The formula contains three useful facts that NEET questions often test.
- If l = 50 cm, then X = R. The two resistances are equal.
- If l < 50 cm, then X > R. A short left part means a small left resistance, so R is small compared with X.
- If l > 50 cm, then X < R.
For R = 10 ohm the table shows how X changes with l.
| l (cm) | 100 - l (cm) | X = 10(100 - l)/l (ohm) |
|---|---|---|
| 20 | 80 | 40 |
| 30 | 70 | 23.33 |
| 40 | 60 | 15 |
| 50 | 50 | 10 |
| 60 | 40 | 6.67 |
| 80 | 20 | 2.5 |
The relation is not linear. Near the ends of the wire, a small change in l changes X a lot. This affects the accuracy, as the next section shows.
Worked example
A resistance box gives R = 10 ohm in the left gap. The null point is at l = 40 cm from the left end.
- The right part of the wire is 100 - 40 = 60 cm.
- X = 10 x 60 / 40 = 15 ohm.
If the same balance length were found with X in the left gap and R in the right gap, the roles swap and the formula becomes X = R l / (100 - l). With R = 10 ohm and l = 40 cm this gives X = 6.67 ohm. Always check which gap holds the known resistance before you substitute.
def meter_bridge_unknown(known_resistance, balance_length_cm, known_on_left=True):
l = balance_length_cm
if not 0 < l < 100:
raise ValueError("balance length must lie strictly between 0 and 100 cm")
if known_on_left:
# R in the left gap, l measured from the left end
return known_resistance * (100 - l) / l
# R in the right gap, l still measured from the left end
return known_resistance * l / (100 - l)
def percent_error_in_x(l, delta_l=0.1):
# dX/X = delta_l/l + delta_l/(100 - l), expressed in percent
return 100 * (100 * delta_l) / (l * (100 - l))
print(meter_bridge_unknown(10.0, 40.0))
print(round(meter_bridge_unknown(10.0, 40.0, known_on_left=False), 2))
print(round(percent_error_in_x(50.0), 2))
print(round(percent_error_in_x(10.0), 2))The program prints 15.0, 6.67, 0.4 and 1.11. The last two numbers are explained in the next section.
Why the balance point should be near the middle
A reading of l has an uncertainty, which we call delta l (for example 0.1 cm for the jockey position). Take logarithms of X = R(100 - l)/l and differentiate:
delta X / X = delta l / l + delta l / (100 - l) = 100 delta l / [l (100 - l)]
The product l(100 - l) is largest at l = 50 cm, so the fractional error in X is smallest there. With delta l = 0.1 cm, the error is 0.4% at l = 50 cm but 1.11% at l = 10 cm. This is why you adjust R until the null point falls roughly between 40 cm and 60 cm.
End corrections and interchanging R and X
The ends of the wire are joined to thick copper strips. These strips have a small resistance and the contacts add a little more. The effective wire lengths are therefore slightly longer than the scale readings. If alpha and beta are the end corrections on the left and right, the true balance condition is:
R / X = (l + alpha) / (100 - l + beta)
You do not need to know alpha and beta. Take one reading with R on the left and X on the right, giving l1. Then interchange R and X and find the new balance length l2. Both readings use the same end corrections, so averaging the two values of X reduces the error from them. For the second reading, use the formula for the swapped arrangement.
Common mistakes
- Wrong end for l. Measuring l from the right end while using X = R(100 - l)/l inverts the answer.
- Sliding the jockey. Dragging the jockey along the wire changes the wire's cross-section and gives a false reading. Touch it down and lift it each time.
- Heating. A current that stays on for a long time warms the wire and changes its resistance. Close the key only while you take a reading.
- Using the percent of 100. The factor (100 - l) is a length in cm, so keep l in cm. Do not convert l to metres in one place only.
- Several readings. Report the mean of X over at least three different values of R. Do not average the l values.
NEET-style pattern
A typical question gives R, the null point and a changed arrangement, such as a second resistance added in series or parallel with X, and asks for the new null point. Work in two steps. First find X from the first balance. Then find the equivalent resistance of the new combination and use l = 100 R / (R + Xeq), which follows from R / Xeq = l / (100 - l).
Exercise
In a meter bridge, a 5 ohm resistance is in the left gap and an unknown resistance X is in the right gap. The balance point is 60 cm from the left end. Find X. Then find the new balance length if X is placed in parallel with another 5 ohm resistor.
Show answer
X = 5 x (100 - 60) / 60 = 3.33 ohm. In parallel with 5 ohm, the equivalent resistance is (3.33 x 5)/(3.33 + 5) = 2 ohm. The new balance length satisfies l = 100 x 5 / (5 + 2) = 71.4 cm from the left end.
Exercise
A student measures the balance length as 25.0 cm with an uncertainty of 0.1 cm. Find the percentage uncertainty in X, and say whether a balance at 50 cm would be better.
Show answer
The percent error is 100 x 100 x 0.1 / (25 x 75) = 0.53%. At 50 cm it would be 0.4%, so a balance near the middle is better.