Sub topic 5
Taking a vernier calliper reading step by step
This chapter assumes you know that 1 cm = 10 mm and can add decimals. It also assumes you know the least count formula from the earlier chapters: least count (LC) = 1 main scale division (MSD) − 1 vernier scale division (VSD). Here you will turn that into a repeatable reading routine, practise it on two instruments, and learn the mistakes that cost marks.
The one formula to remember
Every vernier calliper reading has two parts:
Observed reading = MSR + (VSD × LC)
- MSR is the main scale reading. It is the last main scale mark that lies at or to the left of the vernier zero.
- VSD is the vernier scale division count. It is the number of the vernier line that coincides with (lines up with) any main scale line.
- LC is the least count, the value of one vernier division in the reading.
The MSR gives the coarse part of the value. The vernier gives the fine part, in steps of one LC. The instrument cannot resolve anything smaller than one LC.
The reading routine
Follow the same order every time, so you do not skip a step under exam pressure.
- Find the LC. Use the data given, or work it out. If 10 VSD = 9 MSD and 1 MSD = 1 mm, then 1 VSD = 0.9 mm and LC = 1 − 0.9 = 0.1 mm = 0.01 cm.
- Read the MSR. Look at where the vernier zero falls on the main scale. Take the mark just to its left. If the zero sits between 2.3 cm and 2.4 cm, the MSR is 2.3 cm.
- Find the VSD. Scan along the vernier for the line that lines up exactly with a main scale line. Count its position from the vernier zero. Do not count the zero line itself as the first division.
- Combine. Compute MSR + VSD × LC, and keep the unit the same throughout.
- Correct. Subtract the zero error, with its sign. The next chapter covers how to find that error.
Worked example 1: LC = 0.01 cm
A calliper has 1 MSD = 0.1 cm (1 mm), and 10 VSD coincide with 9 MSD.
- LC = 0.1 / 10 = 0.01 cm.
- The vernier zero lies just past the 2.3 cm mark, so MSR = 2.3 cm.
- The 6th vernier line coincides with a main scale line, so VSD = 6.
- Observed = 2.3 + 6 × 0.01 = 2.36 cm.
Suppose the calliper has a zero error of +0.02 cm, meaning the closed jaws read 0.02 cm instead of 0. Then the corrected reading is 2.36 − 0.02 = 2.34 cm. This code does the same calculation:
def vernier_reading(msr_cm, vsd, least_count_cm, zero_error_cm=0.0):
# Observed = main scale reading + vernier division x least count
observed = msr_cm + vsd * least_count_cm
# Corrected = observed - zero error (zero error is signed)
return observed - zero_error_cm
# 1 MSD = 0.1 cm, 10 VSD = 9 MSD, so LC = 0.1/10 = 0.01 cm
print(round(vernier_reading(2.3, 6, 0.01, zero_error_cm=0.02), 2))The program prints 2.34. The round call hides floating-point noise such as 2.3399999999999999.
Worked example 2: a 20-division vernier
Some callipers have 20 vernier divisions that cover 19 main scale divisions. Take 1 MSD = 1 mm.
- 20 VSD = 19 MSD, so 1 VSD = 19/20 mm = 0.95 mm.
- LC = 1 − 0.95 = 0.05 mm = 0.005 cm.
- Say MSR = 4.1 cm and the 13th line coincides.
- Observed = 4.1 + 13 × 0.005 = 4.165 cm.
The result has three decimal places in cm, because this instrument resolves 0.005 cm.
| Vernier type | Relation | 1 MSD | LC |
|---|---|---|---|
| 10 divisions | 10 VSD = 9 MSD | 1 mm | 0.1 mm = 0.01 cm |
| 20 divisions | 20 VSD = 19 MSD | 1 mm | 0.05 mm = 0.005 cm |
| 50 divisions | 50 VSD = 49 MSD | 1 mm | 0.02 mm = 0.002 cm |
In general, LC = (value of 1 MSD) / (number of vernier divisions), when N VSD = (N − 1) MSD.
Why the coinciding line gives the extra digits
The vernier divisions are slightly shorter than main scale divisions. The n-th vernier line sits n × LC behind the main scale line it is next to. So the vernier zero is ahead of the MSR mark by exactly VSD × LC. This works only if the coinciding line is the one where the two lines match best, so you must judge that carefully.
Edge cases
- Vernier zero exactly on a main scale line. The MSR is that mark and VSD = 0. The observed reading is just the MSR, for example 3.4 cm.
- The last vernier line (VSD = 10) coincides. This means the vernier zero is almost at the next main scale mark. The reading, for example 2.3 + 10 × 0.01 = 2.40 cm, equals the next mark. In practice, check whether VSD = 0 on the next mark also looks aligned. Both give the same value.
- Two adjacent lines look equally good. Take the average of the two readings. The result is a half-LC value, such as 2.365 cm. In NEET questions the coinciding line is stated outright, so this case only arises in a real lab.
- Reading in mixed units. Main scales are often marked in cm with mm subdivisions. Convert the LC to the same unit as the MSR before you add. A common slip is adding 6 × 0.1 to 2.3 cm, when 0.1 is the LC in mm.
Common errors
- Taking the MSR as the mark to the right of the vernier zero. This makes the answer too large by one MSD.
- Counting the vernier zero line as division 1. This shifts VSD by one and adds one LC of error.
- Using the wrong LC. Always check how many vernier divisions there are and what 1 MSD equals.
- Forgetting the sign of the zero error. A positive zero error is subtracted, and a negative zero error is added.
- Reporting too many digits. Report the result to the same decimal place as the LC, so 2.34 cm and not 2.3400 cm.
- Reading at an angle. Look straight down at the scale to avoid parallax, the apparent shift of a line caused by your viewing angle.
Practice
Exercise
A vernier calliper has 1 MSD = 1 mm and 10 VSD = 9 MSD. The closed jaws read zero error +0.03 cm. When measuring a cylinder, the vernier zero lies between 3.5 cm and 3.6 cm and the 4th vernier line coincides. Find the corrected diameter.
Show answer
LC = 0.1 mm = 0.01 cm. Observed = 3.5 + 4 × 0.01 = 3.54 cm. Corrected = 3.54 − 0.03 = 3.51 cm.
Exercise
A calliper has 20 vernier divisions equal to 19 main scale divisions, and 1 MSD = 1 mm. Find the LC in cm, then the reading when MSR = 1.8 cm and the 9th vernier line coincides (no zero error).
Show answer
1 VSD = 0.95 mm, so LC = 0.05 mm = 0.005 cm. Reading = 1.8 + 9 × 0.005 = 1.845 cm.