Sub topic 9
Taking a screw gauge reading step by step
This chapter assumes you know how least count is defined (the smallest reading an instrument can reliably give) and that you can handle simple decimal arithmetic. You should also know what a signed zero error means, though the next chapter covers zero and backlash errors in full. Here the goal is a reliable procedure for turning what you see on the instrument into a number.
What you are reading
A screw gauge has two scales that work together.
- The linear scale (also called the main or pitch scale) is marked along the fixed sleeve. It gives whole millimetres, and often half millimetres.
- The circular scale (also called the head scale) is marked around the rotating thimble. It gives the fraction of one turn.
- The reference line runs along the sleeve. The circular scale division that sits on this line is the one you read.
The pitch is the distance the screw advances in one full turn of the thimble. The least count (LC) is the pitch divided by the number of circular scale divisions:
LC = pitch / number of circular divisions
For a gauge with a 0.5 mm pitch and 50 circular divisions, LC = 0.5 / 50 = 0.01 mm. For a gauge with a 1 mm pitch and 100 divisions, LC is also 0.01 mm.
You can also find the pitch from the instrument. Turn the thimble through a known number of full rotations. Then divide the distance moved along the linear scale by the number of rotations.
The reading formula
The total reading is the linear scale reading plus the circular scale reading multiplied by the least count:
Observed reading = LSR + (CSR × LC)
Here LSR is the linear scale reading and CSR is the circular scale reading, which is the number of the division on the reference line. If the gauge has a zero error, you then subtract it with its sign:
Corrected reading = Observed reading − zero error
The procedure
- Find the least count. Do this before touching the readings. Count the circular divisions and measure or read the pitch.
- Read the linear scale. Note the last linear scale mark that is fully visible, meaning the thimble edge has uncovered it. If the gauge has half-millimetre marks, include them. A visible half-mm mark after 2 mm means the LSR is 2.5 mm.
- Read the circular scale. Note the circular division that lines up with the reference line.
- Combine. Compute LSR + CSR × LC.
- Correct. Subtract the signed zero error found with the gap closed.
Worked example
A gauge has a pitch of 0.5 mm and 50 circular divisions. With a wire in the gap, the thimble edge has uncovered the 2.0 mm mark but not the 2.5 mm mark. The 27th circular division is on the reference line. With the gap closed, the zero of the circular scale is 2 divisions below the reference line, so the zero error is +0.02 mm.
- LC = 0.5 / 50 = 0.01 mm
- Observed = 2.0 + 27 × 0.01 = 2.27 mm
- Corrected = 2.27 − 0.02 = 2.25 mm
The code below does the same calculation.
def screw_gauge_reading(pitch_mm, circular_divisions, lsr_mm, csr, zero_error_mm=0.0):
least_count = pitch_mm / circular_divisions
observed = lsr_mm + csr * least_count
return observed - zero_error_mm
# Pitch 0.5 mm, 50 circular divisions, so LC = 0.01 mm
print(round(screw_gauge_reading(0.5, 50, 2.0, 27, zero_error_mm=0.02), 2))It prints 2.25. The round call only hides floating point noise such as 2.2500000000000004. In an exam, keep the answer to the least count's decimal place.
A second example with a negative zero error
A gauge has a pitch of 1 mm and 100 circular divisions, so LC = 0.01 mm. With the wire in place, LSR = 3 mm and CSR = 46. With the gap closed, the zero of the circular scale is 3 divisions above the reference line, so the zero error is −0.03 mm.
- Observed = 3 + 46 × 0.01 = 3.46 mm
- Corrected = 3.46 − (−0.03) = 3.49 mm
The sign does the work here. A negative zero error means the gauge under-reads, so the correction increases the reading.
| Quantity | Example 1 | Example 2 |
|---|---|---|
| Pitch | 0.5 mm | 1 mm |
| Circular divisions | 50 | 100 |
| Least count | 0.01 mm | 0.01 mm |
| LSR | 2.0 mm | 3 mm |
| CSR | 27 | 46 |
| Observed | 2.27 mm | 3.46 mm |
| Zero error | +0.02 mm | −0.03 mm |
| Corrected | 2.25 mm | 3.49 mm |
Common errors in reading
Misreading the linear scale
The most frequent mistake is taking the wrong linear mark when the thimble edge sits close to a mark. Use the circular reading as a check. If the thimble edge is just past a mark, the CSR should be small. If the edge is just short of a mark, the CSR should be large, near the top of the circular scale. If these two disagree, you have taken the wrong LSR.
Pitch and half-millimetre marks
Some gauges mark the linear scale in half millimetres and some only in whole millimetres. The pitch tells you which one you have. A 0.5 mm pitch means one turn moves the thimble from one half-mm mark to the next. A 1 mm pitch means one turn moves it from one mm mark to the next. Do not assume the pitch is 1 mm. Compute it.
Unit slips
Linear scale marks are in mm, so the answer is in mm. If a question wants a result in cm or m, convert at the end. A reading of 2.25 mm is 0.225 cm and 2.25 × 10⁻³ m.
Wrong sign on the correction
The rule never changes: corrected = observed − zero error, where the zero error carries its own sign. If you subtract a negative error, you add its size. Decide the sign of the error first, then apply the rule without thinking about it.
Taking a good reading
- Close the gap with the ratchet (the small knob at the end of the thimble) and not by turning the thimble directly. The ratchet slips at a fixed pressure, so you do not squeeze the wire or strip the screw.
- Take the zero reading before and after the measurement, and use the same turning technique each time.
- Measure the wire at several places and in two perpendicular directions. A wire is rarely perfectly round or uniform, and the mean diameter is what you want.
- Keep your eye straight in front of the reference line. Looking from the side shifts the apparent division (parallax).
Quick check on precision
With LC = 0.01 mm, a reading is reliable to the second decimal place in mm. Quoting 2.250 mm would claim more precision than the instrument has. Quoting 2.3 mm would throw precision away. Report 2.25 mm.
Exercise
A screw gauge has a pitch of 1 mm and 100 circular divisions. A wire reads LSR = 4 mm and CSR = 38. With the gap closed, the zero of the circular scale is 4 divisions below the reference line, so the zero error is +0.04 mm. Find the corrected diameter.
Show answer
LC = 1/100 = 0.01 mm. Observed = 4 + 38 × 0.01 = 4.38 mm. Corrected = 4.38 − 0.04 = 4.34 mm.
Exercise
A screw gauge has a pitch of 0.5 mm and 50 circular divisions. The thimble edge is just past the 1.5 mm mark and the CSR is 4. The zero error is −0.03 mm. Find the corrected reading, and say whether the CSR is consistent with the edge position.
Show answer
LC = 0.5/50 = 0.01 mm. Observed = 1.5 + 4 × 0.01 = 1.54 mm. Corrected = 1.54 − (−0.03) = 1.57 mm. The CSR of 4 is small, which fits an edge just past a mark, so the LSR of 1.5 mm is consistent.