Sub topic 15
Meter Bridge Precautions and Sources of Error
This chapter assumes you know the Wheatstone bridge balance condition, the meter bridge formula X = R(100 − l)/l, and how to find a balance length with a jockey. Here you will learn which precautions the experiment needs, why each one matters, and how each source of error changes the result.
Why precautions matter
The meter bridge gives X from one measured length l. A small error in l, or a small change in the wire's resistance during the experiment, passes directly into X. Most precautions exist for one of three reasons:
- To keep the wire's resistance constant (heating).
- To keep the measured length accurate (jockey, end errors, parallax).
- To keep the balance point sharp and sensitive (choice of R, clean contacts).
Standard precautions
| Precaution | Reason |
|---|---|
| Keep the key open except while taking a reading, and use low current | Current heats the wire. Resistance rises with temperature, so both the wire and X drift. |
| Press the jockey lightly and touch it, do not slide it | Sliding scrapes the wire and makes its cross-section uneven. This changes resistance per unit length. |
| Keep all connections tight and clean | Loose or oxidised contacts add unknown resistance and make the galvanometer deflection unsteady. |
| Use thick copper strips and short, thick connecting wires | Their resistance is then negligible next to R and X. |
| Choose R so the balance point lies between 40 cm and 60 cm | The percentage error in X is smallest near the middle of the wire (see below). |
| Check that the wire is uniform and straight along the scale | The method assumes resistance is proportional to length. |
| Interchange R and X and average the two results | This partly cancels end errors. |
| Look straight down at the scale when reading l | This avoids parallax. |
Why the middle of the wire is best
From X = R(100 − l)/l, taking logarithms and differentiating gives the relative error in X:
ΔX/X = Δl/l + Δl/(100 − l) = 100·Δl / (l(100 − l))
For a fixed Δl, the denominator l(100 − l) is largest when l = 50 cm. So the fractional error in X is smallest there. Near the ends, l or (100 − l) is small, and the same Δl produces a much larger relative error.
| l (cm) | l(100 − l) | Relative error ΔX/X for Δl = 0.1 cm |
|---|---|---|
| 10 | 900 | 1.11% |
| 30 | 2100 | 0.48% |
| 50 | 2500 | 0.40% |
| 90 | 900 | 1.11% |
The following code reproduces these values.
def relative_error_percent(l_cm, dl_cm):
# (dX/X) = 100*dl / (l*(100 - l)), expressed as a percentage
return 100 * (100 * dl_cm / (l_cm * (100 - l_cm)))
for l in (10, 30, 50, 90):
print(l, round(relative_error_percent(l, 0.1), 2))In practice, if the first balance point is far from 50 cm, change R. If X is larger than R, the balance point moves toward the right end. Increase R to bring it back toward the middle.
Sources of error
End errors
The wire of length 100 cm is joined to the copper strips by soldered or screwed contacts. The scale zero does not coincide exactly with the point where the wire's resistance begins. This adds a small extra resistance at each end, so the measured l is not the true electrical length.
End errors can be treated as extra lengths α and β added at the two ends. The measured balance condition becomes:
R / X = (l + α) / (100 − l + β)
Two ways to reduce the effect:
- Interchange R and X, take the balance length again, and average the two values of X.
- Keep the balance point near 50 cm, where the end contributions are a small fraction of each segment.
Heating of the wire
Current produces heat (I²R). A warm wire has higher resistance, and this resistance is no longer uniform if the heating is uneven. Keep the key closed only for the moment you press the jockey.
Non-uniform wire
If the cross-section or material varies along the wire, equal lengths no longer have equal resistance, and the length ratio no longer equals the resistance ratio. The wire is typically manganin or constantan, chosen for a low temperature coefficient of resistance and uniform drawing. A non-uniform wire cannot be corrected by averaging, so a good wire is the only remedy.
Contact and connection resistance
Resistance at the binding screws and at the jockey contact is not part of the model. It acts like an extra resistor in series with R or X. Clean the connecting ends with sandpaper and tighten them.
Reading and parallax errors
The scale usually has a least count of 1 mm. An error of 1 mm in l matters. Read with the eye directly above the jockey mark.
Galvanometer sensitivity
A galvanometer that is not sensitive enough shows no deflection over a range of positions. Then the "null" position is poorly defined. A shunt (a low resistance placed in parallel with the galvanometer) is sometimes used at first, to protect it from a large current while the jockey is far from balance. It is removed for the final fine adjustment.
Effect of errors on the result
Worked example
A student uses R = 10.0 Ω and finds l = 40.0 cm. Reading uncertainty Δl = 0.1 cm.
- X = 10.0 × (100 − 40.0)/40.0 = 15.0 Ω.
- ΔX/X = 100 × 0.1 / (40 × 60) = 10/2400 = 0.42%.
- ΔX = 0.0042 × 15.0 ≈ 0.06 Ω.
So X = 15.0 ± 0.06 Ω from the length reading alone. Reading uncertainty in R is not included here.
R = 10.0
l = 40.0
dl = 0.1
X = R * (100 - l) / l
rel = 100 * dl / (l * (100 - l))
print(round(X, 2), round(rel * 100, 2), round(X * rel, 3))Common mistakes
- Treating a balance point near 10 cm or 90 cm as equally reliable as one near 50 cm.
- Leaving the key closed, so the wire warms and the null point drifts slowly.
- Sliding the jockey along the wire instead of tapping it.
- Forgetting that interchanging R and X means using the new l in the formula with the roles swapped. After the swap, X is in the left gap and R is in the right gap, so X = R·l′/(100 − l′).
- Quoting X to more significant figures than l and R support. If l has three significant figures, X should too.
Exercises
Exercise
In a meter bridge experiment the balance point is at 20 cm with R = 8 Ω in the left gap. Find X. Why would a student be advised to change R before recording final data?
Show answer
X = 8 × (100 − 20)/20 = 32 Ω. The balance point at 20 cm is far from the middle, so the relative error 100·Δl/(l(100 − l)) is large. The student should raise R, for example to about 30 Ω, so the balance point moves near 50 cm.
Exercise
Why is manganin or constantan used for the meter bridge wire instead of copper?
Show answer
Manganin and constantan have a very small temperature coefficient of resistance, so a small heating effect barely changes the wire's resistance. They also have high resistivity, so a reasonably long, thin wire gives a usable resistance. Copper's resistance changes noticeably with temperature.
Exercise
With R in the left gap, l = 45.0 cm. After interchanging R and X, the new balance length is l′ = 54.6 cm measured from the left end. Explain why the two resulting values of X may differ and how to report the final value.
Show answer
End errors and contact resistances affect the two arrangements differently. The first gives X1 = R(100 − 45.0)/45.0. The second gives X2 = R × 54.6/(100 − 54.6). Both are calculated and their mean is reported, because averaging cancels much of the end error.