Sub topic 2
Splitting Observed Variation into Process and Measurement Parts
Prerequisites and the working model
This chapter assumes you know how to calculate a mean, variance, and standard deviation. You should also know that a process can vary over time and that specification limits define acceptable results.
Every recorded measurement contains two broad sources of variation:
- Part-to-part variation is the real difference among the items being measured.
- Measurement system variation is the error added by the instrument, method, environment, or person measuring the item.
A useful model is:
Observed variation = part-to-part variation + measurement variation
For independent sources of variation, this relationship is usually written in terms of variance:
σ²observed = σ²part + σ²measurement
The symbol σ means standard deviation. The squared symbol, σ², means variance. Variance is used because independent variances add directly. Standard deviations do not add directly.
A simple numerical example
Suppose a process produces parts with a part-to-part standard deviation of 0.80 mm. The measurement system has a standard deviation of 0.20 mm.
Convert both values to variances:
- Part variance: 0.80² = 0.64 mm²
- Measurement variance: 0.20² = 0.04 mm²
- Observed variance: 0.64 + 0.04 = 0.68 mm²
The observed standard deviation is √0.68, or about 0.825 mm.
The measurement system has increased the apparent standard deviation from 0.80 mm to about 0.825 mm. In this example, the increase is small because measurement variation is much smaller than part variation.
Now suppose the measurement system standard deviation is 0.80 mm instead. The observed variance becomes:
0.80² + 0.80² = 1.28 mm²
The observed standard deviation is about 1.13 mm. The process now appears much less consistent than it really is. Decisions based on these measurements may be wrong.
| Component | Standard deviation | Variance |
|---|---|---|
| Part-to-part | 0.80 mm | 0.64 mm² |
| Measurement system | 0.20 mm | 0.04 mm² |
| Observed total | 0.825 mm | 0.68 mm² |
Why decomposition matters
If you do not separate these sources, you cannot tell whether to improve the process or the measurement system.
For example:
- Large part-to-part variation with small measurement variation points toward process improvement.
- Small part-to-part variation with large measurement variation points toward measurement-system improvement.
- Large variation in both requires attention to both areas.
- Very little observed variation can mean the selected parts are too similar, not that the measurement system is excellent.
A gage R&R study estimates the measurement portion by having multiple operators measure multiple parts repeatedly. It then separates the observed variation into components such as repeatability and reproducibility. The resulting estimates help answer a practical question: can this measurement system distinguish meaningful differences between parts?
The decomposition is an estimate, not a permanent property of the instrument. It depends on the parts selected, the measurement range, the operators, the method, and the study conditions.
Exercise
A study estimates a part-to-part variance of 0.36 and a measurement variance of 0.13. What fraction of the total variance comes from the measurement system?
Show answer
Total variance is 0.36 + 0.13 = 0.49. The measurement fraction is 0.13 / 0.49, or about 26.5%.