Sub topic 10
Reading Gage R&R Results Against Acceptance Guidelines
Assume you know mean, variance, and standard deviation, and you understand specification limits. This chapter also assumes that a crossed gage R&R study has already been completed and that its variance components have been estimated.
A gage R&R result does not answer only one question. It answers two related questions:
- How much of the observed variation comes from the measurement system?
- Can the measurement system separate parts that differ in a practically important way?
The first question uses percentage measures. The second uses the number of distinct categories.
The main metrics
A study usually reports these measures:
| Metric | What it compares | Main use |
|---|---|---|
| % contribution | Gage R&R variance to total variance | Finds the source of variance |
| % study variation | Gage R&R standard deviation to total standard deviation | Judges measurement spread |
| % tolerance | Six gage R&R standard deviations to specification tolerance | Checks fitness for specifications |
| ndc | Distinguishable part groups | Checks resolution |
% contribution
Let \(V{GRR}\) be the measurement-system variance and \(V{total}\) be total observed variance.
\[ \%Contribution = 100 \times \frac{V{GRR}}{V{total}} \]
This metric uses variance, so it emphasizes large sources of spread. A low value means the measurement system explains little of the study's variance. A high value means measurement error is a major part of what you observed.
% study variation
Study variation commonly uses six standard deviations:
\[ \%Study\ Variation = 100 \times \frac{6s{GRR}}{6s{total}} = 100 \times \sqrt{\frac{V{GRR}}{V{total}}} \]
Because standard deviation is the square root of variance, this percentage is not the same as % contribution. For example, 10% contribution corresponds to about 31.6% study variation.
% tolerance
When specification limits are available, calculate the tolerance width:
\[ T = USL - LSL \]
Then calculate:
\[ \%Tolerance = 100 \times \frac{6s_{GRR}}{T} \]
This measure connects measurement error to the engineering decision. A measurement system can have a high % study variation when the sampled parts are very similar, yet still have a small % tolerance if the specification band is wide.
Number of distinct categories
The number of distinct categories, or ndc, estimates how many separate levels of part variation the measurement system can reliably distinguish:
\[ ndc = \left\lfloor 1.41 \frac{s{part}}{s{GRR}} \right\rfloor \]
A larger value is better. An ndc below 5 usually indicates that the system cannot distinguish enough differences between parts for process analysis.
Common acceptance guidelines
A widely used rule of thumb is:
- Less than 10%: measurement system is generally acceptable.
- 10% to 30%: may be acceptable, depending on the application, cost, risk, and intended use.
- Greater than 30%: generally unacceptable without improvement.
These ranges most often apply to % study variation or % tolerance. State which metric you used. Do not compare a % contribution value directly with a % tolerance guideline.
For ndc, 5 or more is often treated as the minimum for distinguishing part groups. A value of 10 or more gives stronger resolution for detecting process differences.
Making the decision
Use the metrics together rather than accepting a system because one number is small.
- Check % contribution to see whether measurement variance dominates the study.
- Check % study variation to judge the measurement system against total process spread.
- Check % tolerance when specifications determine acceptance.
- Check ndc to confirm that the system can distinguish meaningful part differences.
- Review the operator, part, and repeatability components before choosing an action.
For example, a system with 18% % tolerance and ndc of 7 may be conditionally acceptable for routine monitoring. The same system may be unsuitable for a safety-critical final inspection. Also check whether one operator or one part range caused the result.
Exercise
A study reports 6% contribution, 24% study variation, 12% tolerance, and ndc = 8. Is the system automatically acceptable?
Show answer
No. The results are generally promising, but the 24% study variation falls in the conditional range. Confirm the measurement purpose, inspect the component results and graphs, and document the risk-based decision.