Sub topic 7
Series, parallel and mixed grouping of cells
This chapter assumes you know how a single cell with EMF E and internal resistance r behaves, with terminal voltage V = E − Ir. It also assumes you can reduce series and parallel resistor networks. One cell often cannot supply the voltage or current a circuit needs, so cells are grouped. The task is to replace the whole group by one equivalent cell with EMF Eeq and internal resistance req. After that, every formula for a single cell applies.
The equivalent-cell idea
A battery of cells connected to a load R behaves like one cell (Eeq, req) connected to R. The load current is then
I = Eeq / (R + req)
Each grouping below is a rule for finding Eeq and req.
Series grouping
In series, the positive terminal of one cell joins the negative terminal of the next. The same current passes through every cell. The EMFs add, and so do the internal resistances.
For n identical cells (each E, r):
- E_eq = nE
- r_eq = nr
- I = nE / (R + nr)
Series grouping pays off when R is much larger than nr. In that case I ≈ nE/R, so n cells give about n times the current of one cell. If R is much smaller than r, then I ≈ E/r, and adding cells gains nothing.
If a cell is connected with reversed polarity, subtract its EMF but still add its internal resistance. For example, cells of 2 V, 3 V and 1 V with the 1 V cell reversed give E_eq = 2 + 3 − 1 = 4 V. The resistance is r₁ + r₂ + r₃.
Parallel grouping
In parallel, all positive terminals join at one node and all negative terminals at another. The terminal voltage is the same across every cell. The current divides among the cells.
For m identical cells:
- E_eq = E
- r_eq = r/m
- I = E / (R + r/m)
Parallel grouping does not raise the voltage. It lowers the internal resistance, and each cell supplies I/m. It pays off when R is much smaller than r/m, because the battery can then deliver a larger current for longer.
Unequal cells in parallel
Cells with different EMFs and resistances are best treated using conductances 1/r. The general result is
- 1/r_eq = Σ (1/rᵢ)
- E_eq = Σ (Eᵢ/rᵢ) / Σ (1/rᵢ)
Take a 10 V cell with r = 2 Ω in parallel with a 4 V cell with r = 4 Ω. Then:
- E_eq = (10/2 + 4/4) / (1/2 + 1/4) = 6 / 0.75 = 8 V
- r_eq = 4/3 Ω
With no load connected, a circulating current still flows: I = (10 − 4)/(2 + 4) = 1 A. The terminal voltage across the pair is 10 − 1×2 = 8 V, which matches E_eq. The weaker cell is being charged by the stronger one, as in the Kirchhoff example elsewhere in this tutorial.
Mixed grouping
Mixed grouping places m identical rows in parallel, with n cells in series in each row. The total number of cells is N = mn.
- Each row is a series group with EMF nE and resistance nr.
- The m rows are identical, so their parallel combination has EMF nE and resistance nr/m.
The results are:
- E_eq = nE
- r_eq = nr/m
- I = nE / (R + nr/m) = mnE / (mR + nr)
Choosing the best arrangement
For a fixed number of cells N = mn, the current is largest when the denominator mR + nr is as small as possible relative to the numerator. Using mn = N and AM-GM on mR and nr:
mR + nr ≥ 2√(mnRr) = 2√(NRr)
with equality when mR = nr. So the current is maximum when
R = nr/m = r_eq
The external resistance equals the equivalent internal resistance. This is the maximum power transfer condition applied to the battery, covered in a later chapter. The maximum current is then
I_max = nE / (2R)
Because m and n must be whole numbers with mn = N, the exact condition usually cannot be met. You compare the allowed factor pairs and pick the best one.
Worked example
Twelve cells, each E = 1.5 V and r = 0.5 Ω, drive a load R = 2 Ω. The ideal condition gives n/m = R/r = 4, with nm = 12, so n² = 48 and n ≈ 6.9. The nearest factor pairs are n = 6, m = 2 and n = 12, m = 1. The code below checks every pair.
def mixed_current(N, n, E, r, R):
# N cells arranged as m rows of n cells in series
if N % n != 0:
raise ValueError("n must divide N")
m = N // n
return n * E / (R + n * r / m)
N, E, r, R = 12, 1.5, 0.5, 2.0
for n in (1, 2, 3, 4, 6, 12):
m = N // n
print(f"n={n:2d}, m={m:2d}, I={mixed_current(N, n, E, r, R):.3f} A")The output peaks at n = 6, m = 2 with I = 9 / (2 + 1.5) ≈ 2.571 A. Compare n = 12, m = 1, which gives 18/(2 + 6) = 2.25 A, and n = 4, m = 3, which gives 6/(2 + 0.667) = 2.25 A.
Summary of the three groupings, for identical cells:
| Grouping | E_eq | r_eq | Best when |
|---|---|---|---|
| n in series | nE | nr | R ≫ nr |
| m in parallel | E | r/m | R ≪ r/m |
| m rows of n | nE | nr/m | R = nr/m |
Current in each cell
Once the load current I is known, the current through an individual cell follows from the layout.
- In series, every cell carries I.
- In parallel with identical cells, each carries I/m.
- In a mixed group, each row carries I/m, and every cell in a row carries I/m.
The power wasted as heat in the battery is I² r_eq. For a mixed group, that is the total of the heating in all cells. At maximum current transfer, half of the total power is lost inside the battery. Choosing the arrangement for maximum power therefore gives a battery efficiency of 50 percent.
Common errors
- Adding EMFs in parallel. Identical cells in parallel keep the EMF of one cell.
- Forgetting the internal resistance of the cells when working out the series current.
- Treating a reversed cell as if it adds. Subtract its EMF, and still add its r.
- Using the identical-cell formulas for unequal cells. Use the conductance formula, or Kirchhoff's laws.
- Mixing up n and m. Define n as the cells per row and m as the number of rows before substituting.
- Ignoring circulating current in parallel groups of unequal EMF. These cells waste energy and can overheat.
Exercise
Six identical cells, each with E = 2 V and r = 1 Ω, are arranged in 2 rows of 3 cells in series and connected to an external resistance R = 3 Ω. Find the current in the load and the current in each cell.
Show answer
Here n = 3 and m = 2. Eeq = nE = 6 V and req = nr/m = 3/2 = 1.5 Ω. The load current is I = 6/(3 + 1.5) = 4/3 A ≈ 1.33 A. The two rows share this equally, so each cell carries I/m = 2/3 A ≈ 0.67 A.
Exercise
A 6 V cell with r = 1 Ω is connected in parallel with a 3 V cell with r = 2 Ω, and the pair drives a load R = 2 Ω. Find Eeq, req and the load current.
Show answer
1/req = 1/1 + 1/2 = 1.5, so req = 2/3 Ω. E_eq = (6/1 + 3/2)/1.5 = 7.5/1.5 = 5 V. The load current is I = 5/(2 + 2/3) = 5/(8/3) = 15/8 = 1.875 A.