Sub topic 16
Effect of non-ideal meters on measurements
This chapter assumes you know Ohm's law, series and parallel resistors, EMF and internal resistance, and how a galvanometer becomes an ammeter or voltmeter. Earlier chapters treated meters as ideal. Here you will see how real meters change the quantity they measure, and how to estimate the error.
The ideal and the real meter
An ideal ammeter has zero resistance, so inserting it does not change the current. An ideal voltmeter has infinite resistance, so connecting it draws no current.
Real meters miss both ideals:
- An ammeter has a small resistance R_A. It adds to the circuit's resistance and lowers the current.
- A voltmeter has a large but finite resistance R_V. It draws some current and lowers the voltage it is trying to read.
Converted galvanometers show the pattern. A galvanometer of resistance G with a shunt S in parallel has RA = GS/(G + S), which is slightly less than S. A voltmeter made with a series resistance Rs has RV = G + Rs.
A general rule for loading error
Replace the rest of the circuit, as seen by the meter, with an equivalent source and resistance R_th (the Thevenin form). Then:
- A series ammeter reads Iread = Itrue × Rth / (Rth + R_A). The reading is always too low.
- A parallel voltmeter reads Vread = Vtrue × RV / (RV + R_th). The reading is always too low.
The relative error is small when RA is much smaller than Rth, and when RV is much larger than Rth. Both rules follow from the idea that a meter should be "invisible" compared with the circuit around it.
Worked example: ammeter
A 6 V cell with negligible internal resistance drives a 2 Ω resistor. The true current is 3 A. An ammeter with R_A = 1 Ω reads 6/(2 + 1) = 2 A. The error is 33%, because the ammeter's resistance is not small compared with 2 Ω.
Worked example: voltmeter
A 10 V source feeds two 10 kΩ resistors in series. The voltage across the second resistor is 5 V. A voltmeter of 10 kΩ across it makes the parallel combination 5 kΩ. The reading is 10 × 5/(10 + 5) = 3.33 V, which is far from 5 V.
Measuring a resistance with an ammeter and voltmeter
To find R from R = V/I, you need V across the resistor and I through it. There are two ways to connect the meters, and each has a systematic error.
Connection A: voltmeter across the resistor only
The ammeter sits outside the voltmeter, so it reads the resistor's current plus the voltmeter's current. The voltage is correct and the current is too large, so the computed value is too small:
Rmeas = V/(IR + V/RV) = R RV / (R + R_V)
The fractional error is −R/(R + RV), which is about −R/RV when R is much smaller than R_V.
Connection B: voltmeter across the resistor and the ammeter
The current is correct, but the voltmeter also reads the drop across the ammeter. The computed value is too large:
Rmeas = R + RA
The fractional error is +R_A/R.
| Property | Connection A (voltmeter across R) | Connection B (voltmeter across R and ammeter) |
|---|---|---|
| Measured value | R in parallel with R_V | R + R_A |
| Sign of error | Reads low | Reads high |
| Size of error | About R/R_V | R_A/R |
| Best for | Low resistance (R much less than R_V) | High resistance (R much greater than R_A) |
The two errors have equal size when R/(R + RV) = RA/R, which gives R² ≈ RA RV for R much less than R_V. Below this value connection A is better. Above it, connection B is better.
Checking the formulas numerically
def connection_a(R, R_V):
# Voltmeter across the resistor only: R in parallel with the voltmeter
return R * R_V / (R + R_V)
def connection_b(R, R_A):
# Voltmeter across resistor and ammeter: the ammeter resistance adds
return R + R_A
R_A, R_V = 0.5, 1000.0
for R in (10.0, 10000.0):
a = connection_a(R, R_V)
b = connection_b(R, R_A)
print(f"R = {R:8.1f} A reads {a:9.3f} B reads {b:9.3f}")The output is:
R = 10.0 A reads 9.901 B reads 10.500
R = 10000.0 A reads 909.091 B reads 10000.500For the 10 Ω resistor, connection A is off by 1% and B by 5%, so A is better. For the 10 kΩ resistor, A is off by more than 90% and B by 0.005%, so B is better. Here √(RA RV) is about 22 Ω, which separates the two cases.
Voltmeters and cells
A voltmeter placed across a cell reads the terminal voltage, not the EMF. With a current I = E/(r + R_V):
V = E RV / (RV + r)
The reading is close to E only if R_V is much greater than r. This is why a high-resistance voltmeter is used to estimate the EMF of a cell, and why the result is always a slight underestimate.
Null methods avoid the problem
Some instruments are designed so that the loading error vanishes at the moment of measurement.
- Potentiometer. At balance, no current flows through the cell being measured, so the potentiometer acts as a voltmeter with infinite resistance. It gives the true EMF, which an ordinary voltmeter cannot do.
- Wheatstone bridge and meter bridge. At balance the galvanometer current is zero. Its resistance has no effect on the balance condition, although it does affect how sensitive the null detection is.
These methods are accurate because the meter draws no current at the point of reading.
Common errors
- Error direction. A series ammeter always reads too low, and a parallel voltmeter always reads too low. Connection A gives R too low and B gives R too high. Mixing up the signs is a frequent mistake.
- Comparing with the wrong resistance. The criterion is RV against Rth (the resistance of the circuit across the meter's terminals), not against the resistor's own value. Find the equivalent resistance seen by the meter's terminals.
- Changing the circuit twice. In a divider, a voltmeter changes the resistance of one arm, so recompute the whole divider with the parallel combination. Do not just correct the final reading.
- Treating a shunt as the ammeter resistance. RA = GS/(G + S). It is close to S, but it is not equal to S. For a 0 to 1 A ammeter with G = 100 Ω and Ig = 1 mA, S = 0.1001 Ω, so R_A = 0.1 Ω exactly.
- Assuming a higher range is always better. Extending a voltmeter's range increases RV, which reduces loading. For an ammeter the opposite holds: extending the range lowers RA, so a larger range disturbs the circuit less but reads less precisely at small currents.
Practice
Exercise
A resistor of true value 100 Ω is measured with connection A, where the voltmeter (R_V = 1000 Ω) is across the resistor only. What value is computed from V/I, and what is the percentage error?
Show answer
R_meas = 100 × 1000 / (100 + 1000) = 90.9 Ω. The error is (90.9 − 100)/100 = −9.1%, so the reading is about 9% low.
Exercise
A cell has EMF 3 V and internal resistance 2 Ω. A voltmeter of resistance 198 Ω is connected directly across it. What does the voltmeter read, and is this the EMF?
Show answer
V = E RV/(RV + r) = 3 × 198/200 = 2.97 V. This is the terminal voltage, slightly below the EMF of 3 V.
Exercise
In the 6 V and 2 Ω example, what ammeter resistance would keep the current reading within 1% of the true value?
Show answer
Iread/Itrue = 2/(2 + RA) must be at least 0.99, so 2 + RA is at most 2.0202, which gives R_A of at most about 0.02 Ω.