Sub topic 3
How resistance changes with temperature
This chapter assumes you know Ohm's law, the resistivity formula R = ρL/A, and the drift-velocity picture of current from the earlier chapters. You also need to solve a linear equation for one unknown. Everything here is the linear model JEE expects, plus the situations where it stops working.
The physical reason
Resistivity comes from collisions of charge carriers with the lattice. In the drift model the resistivity is
ρ = m / (n e² τ)
Here n is the number of free carriers per unit volume and τ is the mean time between collisions (relaxation time). Temperature affects these two quantities differently in different materials.
- Metals. n is almost fixed, because each atom contributes its free electrons at any temperature. Hotter ions vibrate more, so collisions are more frequent and τ falls. Resistivity rises.
- Semiconductors and insulators. Heating frees more carriers from bonds, so n rises very quickly. The drop in τ is much smaller than the gain in n, so resistivity falls.
The linear model
For a modest temperature range, resistivity changes in proportion to the temperature change:
ρT = ρ0 [1 + α (T − T_0)]
Multiplying by L/A gives the same form for resistance:
RT = R0 [1 + α (T − T_0)]
R0 is the resistance at the reference temperature T0. α is the temperature coefficient of resistance, with units of per °C (or per K, since only a difference of temperature appears). It is the fractional change in resistance per degree, measured from T_0.
Typical values:
| Material type | Example | Sign of α | Size of α |
|---|---|---|---|
| Pure metal | Copper, platinum, tungsten | Positive | About 4 × 10⁻³ per °C |
| Alloy | Manganin, constantan | Positive or negative | Very small, about 10⁻⁵ per °C or less |
| Semiconductor | Silicon, germanium, thermistor | Negative | Large, and not constant |
| Electrolyte | Salt solution | Negative | Moderate |
Manganin and constantan are used for standard resistors and meter coils because their resistance barely drifts with temperature.
Why the length and area changes are ignored
Heating also lengthens a wire and widens its cross-section. For a solid, the factor L/A changes by about −αL ΔT, where αL is the linear expansion coefficient, around 10⁻⁵ per °C. Compared with α ≈ 4 × 10⁻³ per °C, this is a few tenths of a percent of the effect, so JEE problems ignore it.
Ratio form for two temperatures
When you know the resistance at two temperatures and the reference is T_0 = 0 °C, divide the two equations:
R2 / R1 = (1 + α T2) / (1 + α T1)
This is faster than finding R0 first. The common mistake is to write R2/R1 = 1 + α(T2 − T1). That is only approximately true when α T1 is small, and it is off by several percent for a metal at a few hundred degrees.
Worked examples
Example 1: a coil. A copper coil has R = 10 Ω at 20 °C. Taking α = 0.004 per °C at 20 °C, its resistance at 60 °C is
R = 10 [1 + 0.004 × 40] = 11.6 Ω
Example 2: a hot filament. A 100 W, 220 V bulb has a hot resistance of V²/P = 220²/100 = 484 Ω. Its cold resistance at 20 °C is measured as 40 Ω. For tungsten, α ≈ 4.5 × 10⁻³ per °C. Then
484 / 40 = 12.1 = 1 + α (T − 20)
so T − 20 = 11.1 / 0.0045 ≈ 2467 °C, and T ≈ 2490 °C. The result agrees with the real filament temperature, roughly 2500 °C. The ratio is so large that the linear model is only a rough guide here. Over a range this big, α itself drifts.
The code below works through the same calculation and also converts α between reference temperatures.
def resistance(R_ref, alpha, T, T_ref=20.0):
"""Resistance at temperature T using the linear model."""
return R_ref * (1 + alpha * (T - T_ref))
def temperature(R, R_ref, alpha, T_ref=20.0):
"""Invert the linear model: temperature at which resistance equals R."""
return T_ref + (R / R_ref - 1) / alpha
def shift_alpha(alpha_1, T_1, T_2):
"""Convert a coefficient quoted at T_1 into one measured from T_2."""
return alpha_1 / (1 + alpha_1 * (T_2 - T_1))
# Example 1: copper coil
print(round(resistance(10.0, 0.004, 60.0), 2)) # 11.6
# Example 2: tungsten filament, hot resistance 220**2 / 100 ohm
R_hot = 220**2 / 100
print(round(temperature(R_hot, 40.0, 0.0045), 1)) # 2486.7
# alpha quoted from 0 C is not the same as alpha quoted from 20 C
print(round(shift_alpha(0.004, 0.0, 20.0), 6)) # 0.003704Gotchas
- The reference temperature belongs to α. A coefficient quoted at 0 °C is not the same number as one quoted at 20 °C, as the last line of the code shows. If a problem gives α "at 0 °C", use T_0 = 0 °C in the formula.
- The model is linear only over a limited range. For exact work, resistance follows a polynomial in T. JEE questions stay with the linear form, so use it unless the problem says otherwise.
- Semiconductors are not linear. A thermistor's resistance follows roughly R = R0 exp[B(1/T − 1/T0)] with T in kelvin. A single α describes it only over a very narrow range.
- Resistance is not resistivity. Both obey the same linear law, but if a problem gives you ρ_0 you must still apply L/A.
- Use a consistent temperature unit. A temperature difference is the same number in °C and K. Do not convert °C to K inside an expression of the form (T − T_0).
Applications
Resistance thermometer. Platinum has a stable, nearly linear α, so measuring the resistance of a platinum coil gives the temperature through the inverted formula. A Wheatstone bridge or meter bridge can read the resistance, and the later chapters on those instruments use this idea.
Thermistor. A thermistor with negative α responds strongly to small temperature changes, so it works as a sensitive thermometer or as a protection element in circuits.
Zero-coefficient combination. Two resistors made of materials with opposite signs of α can be joined in series so the total resistance does not change with temperature. Their resistances at the reference temperature must satisfy
R1 α1 + R2 α2 = 0
This follows from the series total R1(1 + α1 ΔT) + R2(1 + α2 ΔT) = (R1 + R2) + (R1 α1 + R2 α2) ΔT. The ΔT term vanishes when the bracket is zero. For example, a copper coil (α1 = +4 × 10⁻³ per °C) with a carbon resistor (α2 = −5 × 10⁻⁴ per °C) needs Rcarbon / Rcopper = 4 × 10⁻³ / 5 × 10⁻⁴ = 8. This condition applies to series only. A parallel pair needs a different condition, because the equivalent resistance is not a sum.
Link to power and heating
A heated metal conductor has higher resistance, so at constant voltage it draws less current and dissipates less power than its cold value suggests. This is why a bulb draws a large current at the moment it is switched on and settles to a lower value as the filament heats up. The power chapter treats this with P = V²/R, where R is the hot value.
Exercise
A platinum resistance thermometer has resistance 5.00 Ω at 0 °C and 5.40 Ω at 100 °C. Assuming a linear variation, find α, and find the temperature when the resistance reads 5.20 Ω.
Show answer
α = (R100 − R0)/(R_0 × 100) = 0.40/(5.00 × 100) = 8 × 10⁻⁴ per °C. For 5.20 Ω: 5.20 = 5.00 [1 + 8 × 10⁻⁴ T], so T = (0.04 × 1/8 × 10⁻⁴) = 50 °C.
Exercise
A copper wire of resistance R1 and α1 = 4 × 10⁻³ per °C, measured from 0 °C, is joined in series with a carbon rod of resistance R2 and α2 = −5 × 10⁻⁴ per °C, also measured from 0 °C. The total is 90 Ω at 0 °C and does not change with temperature. Find R1 and R2.
Show answer
The zero-coefficient condition gives R1 α1 + R2 α2 = 0, so R2 = 8 R1. With R1 + R2 = 90 Ω, 9 R1 = 90 Ω. So R1 = 10 Ω and R_2 = 80 Ω.
Exercise
The resistance of a metal wire is 20.0 Ω at 27 °C and 22.0 Ω at 77 °C. Taking the reference as 0 °C, find the resistance at 0 °C using the ratio form.
Show answer
22.0/20.0 = (1 + 77α)/(1 + 27α) gives 1.1 (1 + 27α) = 1 + 77α, so 1.1 + 29.7α = 1 + 77α and α = 0.1/47.3 ≈ 2.11 × 10⁻³ per °C. Then R_0 = 20.0/(1 + 27α) = 20.0/1.057 ≈ 18.9 Ω.