Sub topic 9
Control Charts: Separating Signal from Noise
Assume you know basic arithmetic, percentages, the mean, and the idea of a distribution. This chapter uses an individuals control chart, which monitors one measurement at a time.
What a control chart shows
A control chart displays process measurements in time order. It contains:
- A center line, usually the process mean.
- An upper control limit (UCL).
- A lower control limit (LCL).
- The measurements plotted in sequence.
Control limits describe the expected behavior of a stable process. They are calculated from process data, commonly at three estimated standard deviations above and below the mean.
Control limits are not the same as specification limits. A control limit comes from the process. A specification limit comes from the customer, design, law, or business requirement. A process can be stable but produce unacceptable output. It can also meet specifications while showing an unstable pattern.
Reading signal from noise
A point outside the control limits is a strong signal of a special cause, which is an unusual event that changes process behavior. Examples include a damaged tool, a wrong material batch, a sensor failure, or an unusual operating condition.
A point inside the limits does not automatically prove that the process is stable. Other warning patterns include:
- Several consecutive points on one side of the center line.
- A steady upward or downward trend.
- Repeating cycles.
- An unusual cluster or sudden change in spread.
The exact rules depend on the charting standard and the risk of false alarms. Use a documented rule set instead of selecting patterns after seeing the data.
Building an individuals chart
For individual observations, estimate process spread from the moving range, the absolute difference between consecutive measurements. The common estimate is:
sigma_hat = average moving range / 1.128UCL = mean + 3 × sigma_hatLCL = mean - 3 × sigma_hat
The constant 1.128 is the expected moving-range factor for pairs of observations.
from statistics import mean
def individuals_chart_limits(data):
if len(data) < 2:
raise ValueError("at least two measurements are required")
moving_ranges = [abs(b - a) for a, b in zip(data, data[1:])]
sigma_hat = mean(moving_ranges) / 1.128
center = mean(data)
return center - 3 * sigma_hat, center, center + 3 * sigma_hat
def out_of_control_points(data):
lcl, _, ucl = individuals_chart_limits(data)
return [(i, x) for i, x in enumerate(data) if x < lcl or x > ucl]
measurements = [10.02, 9.98, 10.05, 9.97, 10.01,
10.03, 9.99, 10.00, 10.04, 9.96]
print("limits:", individuals_chart_limits(measurements))
print("signals:", out_of_control_points(measurements))The returned indexes identify possible signals. Investigate what happened at those times. Do not delete the points unless there is a documented measurement error. Removing inconvenient data hides process information.
Choosing the response
| Chart result | Likely interpretation | Appropriate response |
|---|---|---|
| Random points within limits | Common-cause variation | Improve the whole process if its performance is inadequate |
| Point outside a limit | Possible special cause | Investigate the event and contain its effect |
| Trend or long run | Process shift or drift | Check tools, settings, materials, and operating conditions |
| Stable chart but defects remain | Process is predictable but incapable | Compare its spread and center with specifications |
Exercise
A stable process has all points inside its control limits, but its output frequently exceeds the upper specification limit. Should you search for a special cause first?
Show answer
No. The chart suggests predictable common-cause variation. Reduce the process's overall spread or recenter it against the specification. Continue investigating special causes only if a new control-chart signal appears.