Sub topic 4
Common causes and special causes
This chapter assumes you can compute a mean and a standard deviation, and that you know what a process, an input and an output are. Earlier chapters showed that every process varies. This chapter shows that variation comes in two kinds, and that each kind needs a different response.
Two kinds of variation
Walter Shewhart separated variation into two kinds in the 1920s. W. Edwards Deming later popularized the terms used here.
- Common-cause variation is the steady, expected variation built into the process. It comes from many small influences acting together, and no single one dominates. Examples are tiny temperature drift, normal differences between material lots, and small differences in how operators load a part.
- Special-cause variation is variation from a specific, identifiable source that is not part of the process as normally run. It is also called assignable-cause variation. Examples are a chipped cutting tool, a wrong material grade, a power outage mid-run, or an untrained temporary worker.
A process with only common causes is stable (also called "in statistical control"). Its output is predictable: you can say roughly what range the next result will fall in, even though you cannot say the exact value. A process with special causes is unstable, and you cannot predict its future output from its past.
| Property | Common cause | Special cause |
|---|---|---|
| Source | The system itself, as designed | A specific event, condition or change |
| Pattern over time | Random scatter around a stable center | Spikes, shifts, trends or cycles |
| Predictability | Predictable within limits | Not predictable |
| Typical owner | Management, through process design | The people running the process, with support |
| Right response | Change the system | Find and address the specific cause |
| Wrong response | Blaming individual results | Averaging it away or ignoring it |
Why the distinction matters
The two kinds call for opposite actions, so a mistake in either direction has a cost.
- Treating common-cause variation as special. Suppose a reading is slightly high and you search for a culprit, then adjust the machine. There is no culprit to find, because the reading is within normal noise. Each adjustment adds variation. This error is called tampering, and a later chapter covers it in detail.
- Treating special-cause variation as common. Suppose a real change such as a worn tool shifts the output, and the team says "that's just how the process is." The cause keeps running and the defects continue.
You cannot avoid both errors with certainty, because you only see individual data points. You need a rule that balances them. Control charts, covered in a later chapter, provide that rule. Their limits are set so a stable process rarely triggers a false alarm, while real shifts are caught quickly.
Special causes can be good
A special cause is not always bad. If a supplier switches to a better batch of steel and your defect rate drops, that is a special cause too. It is a change from outside the normal process. The correct response is the same investigation, with a different goal: find out what changed and make it permanent. Teams that celebrate the improvement without identifying the cause usually see the old performance return.
Stable does not mean good
"Common cause only" says nothing about whether the output meets customer requirements. A process can be perfectly stable and still produce 10% defects every day. That is a predictable, consistent failure. When all variation is common-cause, no individual event is to blame, so the only way to improve is to change the system: better equipment, tighter material specifications, a revised method. This is why Six Sigma projects focus on process redesign once special causes are removed.
The reverse also happens. A process can be capable on average yet unstable, and its output will occasionally surprise you. Stability and capability are separate questions. Capability is covered in a later chapter.
Detecting a special cause in data
The next chapters develop control charts properly. For now, the following script shows the core idea in a small form. It builds limits from a baseline period believed to be stable, then checks a new run against those limits.
import random
from statistics import mean, stdev
rng = random.Random(7)
# Baseline: 25 shaft diameters (mm) from a period believed to be stable.
baseline = [rng.gauss(10.00, 0.03) for _ in range(25)]
center = mean(baseline)
sigma = stdev(baseline)
lcl = center - 3 * sigma
ucl = center + 3 * sigma
print(f"limits: {lcl:.3f} to {ucl:.3f}")
# New run: the same process, but a worn tool adds 0.15 mm at index 12.
new_run = [rng.gauss(10.00, 0.03) for _ in range(20)]
new_run[12] += 0.15
signals = [(i, round(x, 3)) for i, x in enumerate(new_run) if x < lcl or x > ucl]
print("signals:", signals)The injected shift is about five standard deviations, so index 12 is flagged. The remaining 19 points vary only by common-cause noise and should stay inside the limits. A stable process still has a small chance, about 0.27% per point under a normal model, of falling outside three-sigma limits by chance alone. An occasional flagged point is therefore a prompt to investigate, not proof of a cause.
Two cautions apply to this approach:
- Contaminated baselines. If the baseline already contains a special cause,
stdevinflates, the limits widen, and later signals are hidden. Check the baseline for obvious outliers first. - Standard deviation as a sigma estimate. For this demonstration, the overall sample standard deviation is acceptable. In practice, charts estimate sigma from short-term differences between points, such as moving ranges, so that a slow drift does not widen its own limits.
Patterns that suggest a special cause
A single point beyond the limits is the most obvious signal, but it is not the only one. Common patterns include:
- A run of many consecutive points on one side of the center line, which suggests the process mean has shifted.
- A steady upward or downward trend, which suggests gradual wear, drift or fatigue.
- Repeating cycles, which suggest shift changes, daily temperature swings or scheduled maintenance.
- Points that hug the center line far too closely, which can mean the data is being averaged, rounded or edited before it is recorded.
Each pattern points toward a category of cause. The questions "when did it start?" and "what changed at that time?" are usually the fastest route to the source.
Working through the response
When a signal appears, a disciplined sequence helps:
- Confirm the data. Check for transcription errors and measurement problems. A broken gauge is itself a special cause.
- Mark the time. Record exactly when the signal began, and compare it with logs of tool changes, material lots, operators and settings.
- Contain the effect. Segregate suspect output so defects do not reach the customer.
- Find the cause. Use tools such as a cause-and-effect diagram or the five whys, which the DMAIC chapter will place in context.
- Prevent recurrence. Fix the cause itself (for example, a tool-change interval), not just the symptom.
For common-cause variation, none of these steps applies, because there is no event to find. The work is analytical: study which inputs contribute most to the spread, then change the process to reduce their influence.
Exercises
Exercise
A packaging line fills bags to a target of 500 g. Over several weeks the fill weights scatter randomly between 493 g and 507 g, with no signals on the chart. The customer now requires every bag to be between 498 g and 502 g. Is the right response to look for special causes? Explain.
Show answer
No. The chart shows only common-cause variation, so the process is stable and no specific event is responsible. The problem is that the stable spread is wider than the new requirement. The response is to change the system, for example with a better filler, more consistent material or a revised method, so that the common-cause spread shrinks. Hunting for a special cause would waste effort, and adjusting the machine after each off-target bag would increase variation.
Exercise
A process has been stable for months. Suddenly one measurement lands beyond the upper control limit. Give two possible explanations, and say what you should check first.
Show answer
Possible explanations are a real special cause (such as a tool failure, a bad material lot or a setup error) or a false alarm, since a stable process still has roughly a 0.27% chance per point of exceeding three-sigma limits. A measurement error is also possible. Check the measurement first (gauge, transcription, units), then compare the time of the point with change logs for materials, settings, tools and operators. If the point is real and nothing else is unusual, watch the next points before making a process change.