Sub topic 10
Vernier calliper and screw gauge: least count and zero error
This chapter assumes you know what a systematic error is, can convert between millimetres and centimetres, and can do simple fractions. Both instruments measure small lengths more finely than a ruler. Both share one idea: the smallest reading you can trust is the least count. Both can also carry a built-in zero error that you must remove from every reading.
Least count: the core idea
The least count (LC) is the smallest length an instrument can measure reliably. For these two instruments it is the difference between the size of one division on the main scale and the size of one division on the auxiliary scale.
A reading always has the same structure:
- Main scale reading, the coarse part, read directly.
- Auxiliary scale reading, the fine part, equal to a division count times the least count.
Total reading = main scale reading + (coinciding division × least count).
The vernier calliper
A vernier calliper has a fixed main scale, usually in millimetres, and a sliding vernier scale. The jaws grip an object for outside lengths. The smaller jaws grip inside a hollow for inner diameters. A thin rod, the depth probe, measures depth.
Deriving the least count
Suppose N vernier divisions (VSD) match exactly (N − 1) main scale divisions (MSD). Then:
N × 1 VSD = (N − 1) × 1 MSD
1 VSD = ((N − 1)/N) × 1 MSD
LC = 1 MSD − 1 VSD = 1 MSD / N
For the common case, 10 vernier divisions match 9 main scale divisions, with 1 MSD = 1 mm. So 1 VSD = 0.9 mm and LC = 1 − 0.9 = 0.1 mm = 0.01 cm.
Reading a vernier calliper
- Note the main scale division just to the left of the vernier zero. This is the main scale reading (MSR).
- Find the vernier division that lines up exactly with any main scale line. Call its number the vernier scale reading (VSR).
- Reading = MSR + VSR × LC.
msd = 1.0 # one main scale division, in mm
n = 10 # vernier divisions that match 9 main scale divisions
least_count = msd / n # 0.1 mm
msr = 24 # main scale reading, in mm
vsr = 6 # vernier division that coincides with a main scale line
zero_error = 0.2 # mm, vernier zero lies to the right of the main zero
reading = round(msr + vsr * least_count, 1)
corrected = round(reading - zero_error, 1)
print(reading, corrected) # 24.6 24.4The observed reading is 24.6 mm. The corrected reading is 24.4 mm, after removing the zero error of +0.2 mm (explained below).
Zero error in a vernier calliper
With the jaws closed, the vernier zero should coincide with the main scale zero. If it does not, there is a zero error.
- Positive zero error: the vernier zero lies to the right of the main zero. Find it as (coinciding vernier division) × LC. For example, if the 2nd division coincides, the error is +2 × 0.1 = +0.2 mm.
- Negative zero error: the vernier zero lies to the left of the main zero. Here the 0 of the vernier is behind. If the 10 on the vernier line coincides with main scale line and the 10th division is not the match, count back: error = −(N − n) × LC, where n is the coinciding division. For example, if the 8th division coincides, the error is −(10 − 8) × 0.1 = −0.2 mm.
The correction rule is always the same:
Corrected reading = Observed reading − Zero error
Keep the sign of the zero error. Subtracting a negative error adds to the reading.
The screw gauge
A screw gauge (micrometer) uses a precisely cut screw. It measures small thicknesses and diameters of wires. It has a pitch scale along the sleeve and a circular scale on the rotating thimble. A ratchet at the end limits the force, so the screw does not squeeze the object.
Pitch and least count
The pitch is the distance the screw moves along its axis in one full turn of the circular scale. It equals the distance between two adjacent lines on the pitch scale (or the distance covered in a given number of turns divided by that number).
LC = pitch / (number of circular scale divisions)
A typical screw gauge has a pitch of 1 mm and 100 circular divisions, so LC = 1/100 = 0.01 mm. Another common type has a pitch of 0.5 mm and 50 divisions, which also gives LC = 0.01 mm.
If the pitch scale is read in a number of turns, compute the pitch first:
pitch = (distance moved) / (number of full rotations)
Reading a screw gauge
Reading = pitch scale reading (PSR) + circular scale reading (CSR) × LC
The PSR is the last visible line on the sleeve scale before the thimble edge. The CSR is the circular division that lines up with the reference line along the sleeve.
Zero error in a screw gauge
Close the gap by turning the ratchet until it clicks. Then read the circular scale against the reference line.
- Positive zero error: the zero of the circular scale is below the reference line, so the scale shows a positive count. If the 5th division is at the reference line, error = +5 × LC.
- Negative zero error: the zero of the circular scale is above the reference line. Then the count is taken from the other end. If the 95th division is at the reference line on a 100-division scale, error = −(100 − 95) × LC = −5 × LC.
Again, Corrected reading = Observed reading − Zero error.
Worked example
A screw gauge has pitch 1 mm and 100 circular divisions. With the gap closed, the 4th division lies at the reference line. A wire is placed. The pitch scale reads 2 mm, and the 36th division is at the reference line.
- LC = 1/100 = 0.01 mm
- Zero error = +4 × 0.01 = +0.04 mm
- Observed = 2 + 36 × 0.01 = 2.36 mm
- Corrected = 2.36 − 0.04 = 2.32 mm
pitch = 1.0 # mm
divisions = 100
lc = pitch / divisions
zero_error = 4 * lc # positive: 4th division at reference when closed
observed = 2.0 + 36 * lc
corrected = observed - zero_error
print(round(lc, 2), round(observed, 2), round(corrected, 2)) # 0.01 2.36 2.32Comparing the two instruments
| Feature | Vernier calliper | Screw gauge |
|---|---|---|
| Principle | Two scales with slightly different division sizes | Screw advancing by a fixed pitch per turn |
| Least count formula | 1 MSD − 1 VSD, or 1 MSD / N | Pitch / circular divisions |
| Typical least count | 0.1 mm (0.01 cm) | 0.01 mm (0.001 cm) |
| Typical use | Cylinder diameter, depth, inner diameter | Wire diameter, thin sheet thickness |
| Zero error check | Vernier zero against main zero | Circular zero against reference line |
| Sign rule | Right of zero is positive | Zero below the reference is positive |
Edge cases and common errors
- Units: keep every part of a reading in the same unit. A main scale in cm and a least count in mm gives a wrong answer.
- Zero error sign: record it before measuring, and apply the rule corrected = observed − zero error without exception.
- Backlash error: a screw gauge must be turned in one direction only. Reversing the turn gives a slack reading. This is a systematic error, which is why the ratchet is used.
- Parallax: look straight at the scale. An angled view shifts the apparent coincidence.
- Alternate scale conventions: if the question says that n vernier divisions equal (n + 1) main divisions, the vernier is "extended" and LC = 1 VSD − 1 MSD in that case, so it is still the absolute difference between the two division sizes.
- Precision: the least count sets the precision. A reading with LC = 0.01 mm should be quoted to the hundredth of a millimetre, which links to significant figures in the next chapters.
Practice
Exercise
A vernier calliper has 20 divisions on the vernier scale that match 19 main scale divisions, and 1 MSD = 1 mm. (a) Find its least count. (b) With the jaws closed, the 3rd vernier division coincides with a main scale line. A rod reads MSR = 31 mm and VSR = 12 when measured. Find the corrected length.
Show answer
(a) LC = 1 MSD / N = 1/20 = 0.05 mm. (b) Zero error = +3 × 0.05 = +0.15 mm. Observed = 31 + 12 × 0.05 = 31.60 mm. Corrected = 31.60 − 0.15 = 31.45 mm.
Exercise
A screw gauge has pitch 0.5 mm and 50 circular divisions. With the gap closed, the 46th division is at the reference line. A wire gives a pitch scale reading of 3 mm and circular reading of 20. Find the diameter of the wire.
Show answer
LC = 0.5/50 = 0.01 mm. The 46th division on a 50-division scale means the zero is above the reference line, so the zero error is −(50 − 46) × 0.01 = −0.04 mm. Observed = 3 + 20 × 0.01 = 3.20 mm. Corrected = 3.20 − (−0.04) = 3.24 mm.