Sub topic 9
Systematic, Random, and Gross Errors
What this chapter assumes
You should already know the difference between accuracy and precision from the previous chapter. Accuracy is how close a measurement is to the true value. Precision is how close repeated measurements are to each other. You should also be comfortable with percentages and with the idea that every measurement carries some uncertainty. This chapter sorts the causes of that uncertainty into three kinds, shows how to recognise each one, and explains what you can do about it. The next chapters turn these ideas into numbers: least count, absolute error, relative error and error propagation.
Error is not a mistake
In physics, the error in a measurement is the difference between the measured value and the true value. The true value is rarely known exactly, so we estimate the size of the error instead. A small error does not mean you did something wrong. Every instrument has limits, and every experiment has surroundings that you cannot fully control.
Errors are grouped by their cause and by how they behave when you repeat the measurement:
- Systematic errors push every reading the same way, by a similar amount.
- Random errors scatter readings unpredictably on both sides of the true value.
- Gross errors come from careless handling, such as misreading a scale or writing down the wrong number.
Systematic errors
A systematic error is an error that tends to be in one direction, either always positive or always negative. Repeating the measurement does not remove it. If a stopwatch runs fast, every time you record is too large, however many trials you take.
Common sources:
- Instrumental errors. These come from the instrument itself. Examples are a zero error in a vernier calliper or screw gauge, a worn or badly marked scale, and a spring balance that has lost its calibration.
- Imperfection in the experimental method. The procedure or the theory behind it ignores something. Examples are measuring the temperature of a body with a thermometer that itself absorbs heat, or using the simple pendulum formula while ignoring the size of the bob.
- Environmental effects. Temperature, pressure, humidity or air currents change the instrument or the quantity measured. A steel metre scale calibrated at 20 °C reads slightly wrong at 40 °C, because the scale expands.
- Personal errors (observational bias). The observer has a habit that always pushes the reading one way. A common example is parallax, which happens when you read a scale from an angle instead of straight on. Always starting the stopwatch a little late is another.
Why averaging does not help
Suppose a screw gauge has a positive zero error of 0.03 mm. Every reading of a wire's diameter comes out 0.03 mm too large. Averaging 100 readings gives a very stable value, but that value is still 0.03 mm too large. The measurement is precise and inaccurate. This is the link to the previous chapter: systematic errors lower accuracy.
Reducing systematic errors
You cannot reduce them by repeating the measurement. You have to find the cause:
- Find the zero error and subtract it from every reading.
- Calibrate the instrument against a standard.
- Improve the method or apply a correction for the neglected effect.
- Take readings with the eye directly in front of the scale to avoid parallax.
- Use a different instrument or method and compare the results.
The zero-error correction is the one that NEET asks about most often. A positive zero error is subtracted. A negative zero error is added, which means subtracting a negative number.
def corrected_reading(observed, zero_error):
"""Zero error is signed: positive if the instrument reads above zero when closed."""
return round(observed - zero_error, 3)
# Screw gauge with a positive zero error of +0.03 mm
readings = [2.53, 2.54, 2.53, 2.55, 2.53] # mm
corrected = [corrected_reading(r, 0.03) for r in readings]
print(corrected) # [2.5, 2.51, 2.5, 2.52, 2.5]
# Same readings with a negative zero error of -0.02 mm
corrected = [corrected_reading(r, -0.02) for r in readings]
print(corrected) # [2.55, 2.56, 2.55, 2.57, 2.55]Random errors
Random errors are errors that appear without a fixed pattern. Repeating the measurement gives slightly different values, some above the true value and some below. The causes are small, uncontrolled changes: a slight draught, tiny vibrations of the table, variation in your reaction time when you press the stopwatch, or fluctuating voltage in an electrical circuit.
Their key property is that they are as likely to be positive as negative. This is why averaging works for them. When you add up many readings, the positive and negative deviations partly cancel, so the mean is closer to the true value than a single reading is.
- More readings give a smaller random error in the mean. The improvement is gradual, because it depends on the number of readings, not on the readings being individually better.
- Random errors cannot be removed completely. They set a limit on the precision of the experiment.
- Random errors are what the terms "precision" and "spread" describe. Widely scattered readings mean large random error.
Random versus systematic: a quick test
Take about ten readings of the same quantity and look at the pattern.
| Pattern in repeated readings | Likely cause | Fix |
|---|---|---|
| All readings close together but all above (or all below) the accepted value | Systematic | Find the source and correct for it |
| Readings scattered on both sides of a central value | Random | Take more readings and use the mean |
| Readings scattered, and the centre is also off | Both | Correct the systematic part, then average |
| One reading far from all the others | Gross | Check it, then repeat or discard it |
import statistics
true_value = 10.0
# Case A: systematic error of +0.5, almost no scatter
a = [10.5, 10.5, 10.6, 10.5, 10.4]
# Case B: no systematic error, noticeable scatter
b = [9.7, 10.2, 10.4, 9.8, 9.9]
for name, data in (("A", a), ("B", b)):
mean = statistics.mean(data)
spread = max(data) - min(data)
print(name, "mean =", round(mean, 2),
"offset from true =", round(mean - true_value, 2),
"spread =", round(spread, 2))
# A mean = 10.5 offset from true = 0.5 spread = 0.2
# B mean = 10.0 offset from true = 0.0 spread = 0.7Case A is precise but not accurate. Case B is less precise, but its mean is accurate. This is the key idea: the offset of the mean shows the systematic error, and the spread shows the random error.
Gross errors
A gross error is a large error caused by carelessness or a blunder. It has nothing to do with the limits of the instrument. Typical cases:
- Reading the wrong division of the scale, or confusing the main scale and the vernier scale.
- Writing 3.52 as 3.25 when recording.
- Using the wrong unit, such as recording millimetres where the table expects centimetres.
- An arithmetic slip in the calculation.
- Using an instrument in the wrong way, for example tightening a screw gauge too hard.
Gross errors are different from the other two in two ways. First, they are avoidable: care, double-checking and a tidy record remove them. Second, they are not part of the uncertainty of the experiment. If you find a reading that is obviously far from the rest, you check what went wrong. You do not include it in the mean as if it were a normal reading. You repeat the measurement if possible.
Comparing the three
| Feature | Systematic | Random | Gross |
|---|---|---|---|
| Direction | Same direction each time | Either direction | Usually large, either direction |
| Cause | Instrument, method, environment, bias | Unpredictable small fluctuations | Carelessness |
| Reduced by repeating and averaging? | No | Yes | No, but it can be spotted |
| Affects mainly | Accuracy | Precision | Both |
| Remedy | Correct or calibrate | Take more readings | Be careful, check, repeat |
Subtypes you may meet
Some question papers name particular kinds of systematic error. It helps to recognise them:
- Zero error: the instrument does not read zero when it should. It is a type of instrumental error.
- Least count error: this is the smallest reading the instrument can resolve. Strictly, it limits the resolution of the instrument and is treated as the uncertainty of a single reading. It is covered fully in the chapter on the vernier calliper and screw gauge.
- Parallax error: a personal error caused by viewing the scale at an angle.
- Backlash error: looseness in the screw of a screw gauge makes the reading depend on the direction you turn it.
Worked example
A student measures the length of a metal rod with a metre scale. The scale was calibrated at a lower temperature and has expanded, so it reads about 0.2% short in its divisions. She takes six readings of the rod: 50.1, 50.0, 50.2, 49.9, 50.1 and 52.0 cm.
- The last reading, 52.0 cm, is far from the others. The student checks her notes and finds she misread the scale at one end. This is a gross error. She repeats that reading and gets 50.0 cm.
- The six readings are now 50.1, 50.0, 50.2, 49.9, 50.1, 50.0. The mean is 300.3 / 6 = 50.05 cm. The scatter of about 0.3 cm between highest and lowest is the random error.
- The expanded scale makes every reading too small by the same fraction. This is a systematic error. Averaging does not remove it. She has to apply a correction factor from the scale's calibration.
One experiment contained all three kinds of error, and each needed a different response.
Common mistakes
- Saying that averaging removes all errors. It reduces random errors only.
- Mixing up zero error and zero correction. The correction has the opposite sign to the error. A zero error of +0.03 mm gives a zero correction of -0.03 mm.
- Calling a precise result accurate. Tight clustering shows small random error and says nothing about systematic error.
- Treating the least count as the only error. Systematic and random errors can be larger than the least count.
- Including a blunder in the mean. Check unusual readings before averaging.
Practice
Exercise
A student measures the diameter of a wire ten times with a screw gauge. The readings are all between 1.52 mm and 1.54 mm. The screw gauge has a positive zero error of 0.05 mm that the student did not notice. Which kind of error dominates, and is the measurement precise, accurate, or both?
Show answer
The systematic error dominates, since every reading is too large by 0.05 mm. The measurement is precise because the readings lie close together, but it is not accurate. Averaging will not help. The student must subtract 0.05 mm from each reading to get values near 1.47 to 1.49 mm.
Exercise
Classify each as systematic, random or gross: (a) a stopwatch that runs slow, (b) varying reaction time when starting and stopping a stopwatch, (c) writing 12.4 s as 14.2 s in the table.
Show answer
(a) Systematic: an instrumental error that pushes every reading the same way. (b) Random: the delay varies unpredictably and can be positive or negative. (c) Gross: a recording blunder caused by carelessness.
Exercise
A vernier calliper has a negative zero error of -0.04 cm. It reads 3.26 cm for the length of an object. What is the corrected length?
Show answer
Corrected reading = observed reading minus zero error = 3.26 - (-0.04) = 3.30 cm.