Sub topic 8
Accuracy and precision
This chapter assumes you can compute a mean, work with percentages, and already know what a physical measurement is. It follows the chapter on units and dimensions and comes before the one on types of error. Here you separate two words that everyday speech treats as synonyms. In measurement they describe different properties, and NEET questions test the difference directly.
The two definitions
Accuracy is how close a measured value is to the true value (or the accepted value, when the true one cannot be known).
Precision is how close repeated measurements are to each other. It also describes how finely an instrument resolves a quantity, which is set by its least count.
Accuracy compares your readings to the truth. Precision compares your readings to one another and does not need the truth at all.
- A set of readings can be tightly clustered and still far from the true value. That is high precision with low accuracy.
- A set of readings can be scattered, yet have a mean close to the true value. That is high accuracy of the mean with low precision.
The four combinations
| Case | Readings relative to each other | Mean relative to true value | Typical cause |
|---|---|---|---|
| Accurate and precise | Tightly clustered | Close | Good instrument, careful technique |
| Precise, not accurate | Tightly clustered | Far | Systematic error, such as zero error or a miscalibrated scale |
| Accurate (on average), not precise | Widely scattered | Close | Large random error, averaged out by many trials |
| Neither | Widely scattered | Far | Both kinds of error present |
A worked example
Two students measure a metal rod whose accepted length is 5.00 cm.
- Student 1 records 5.01, 4.99, 5.00 cm.
- Student 2 records 5.32, 5.31, 5.33 cm.
Student 1's mean is 5.00 cm, which matches the accepted value. The readings differ from the mean by at most 0.01 cm. This student is accurate and precise.
Student 2's mean is 5.32 cm. The readings differ from their mean by at most 0.01 cm, so the spread is just as small. But every reading is about 0.32 cm too high. This student is precise but not accurate, which points to a systematic error. A likely cause is a ruler with a worn end, so that its zero mark does not sit at the true start.
Student 2's data show that precision alone tells you nothing about correctness. Collecting more readings will not help, because every reading carries the same offset. This is the main idea to keep for the next chapter, which classifies the errors behind these patterns.
Putting numbers on the idea
You can attach a number to each property.
- Accuracy is measured by the offset of the mean from the true value: bias = mean − true value. A small |bias| means high accuracy.
- Precision is measured by the spread of the readings, for example the mean absolute deviation about the mean. A small spread means high precision.
The following program computes both for four sets of measurements of g, whose accepted value is 9.80 m/s².
true_value = 9.80 # m/s^2
datasets = {
"A": [9.78, 9.80, 9.82, 9.80],
"B": [9.38, 9.42, 9.40, 9.40],
"C": [9.2, 10.4, 9.5, 10.1],
"D": [8.2, 9.0, 8.4, 9.4],
}
for name, values in datasets.items():
mean = sum(values) / len(values)
bias = mean - true_value
spread = sum(abs(v - mean) for v in values) / len(values)
print(name, round(mean, 2), round(bias, 2) + 0.0, round(spread, 2))
# A 9.8 0.0 0.01
# B 9.4 -0.4 0.01
# C 9.8 0.0 0.45
# D 8.75 -1.05 0.45Reading the output:
- Set A has bias 0.0 and spread 0.01. It is accurate and precise.
- Set B has the same spread of 0.01 but a bias of −0.4. It is precise but not accurate.
- Set C has bias 0.0 but spread 0.45. Its mean is accurate, but no single reading can be trusted. Precision is poor.
- Set D has both a large bias and a large spread.
Sets A and B have the same precision and different accuracy. Sets A and C have the same accuracy and different precision. The two properties vary independently.
What controls each property
Precision comes from resolution and random scatter
Two things limit precision.
- Instrument resolution. The least count is the smallest value an instrument can resolve. A screw gauge with least count 0.01 mm is more precise than a metre scale with least count 1 mm, because it can distinguish smaller differences.
- Random scatter. Small unpredictable variations, such as reaction time when starting a stopwatch, make repeated readings differ.
The number of significant figures in a reported result expresses precision. Writing 2.50 cm claims a resolution of 0.01 cm. Writing 2.5 cm claims only 0.1 cm.
Accuracy comes from the absence of systematic offsets
A systematic offset shifts every reading in the same direction. Common sources are:
- zero error in a vernier calliper or screw gauge
- a stopwatch that runs fast or slow
- a faulty scale, for example one stretched by heat
- using a formula that ignores a real effect, such as air resistance
You can correct a known systematic error. For a positive zero error of 0.2 mm, you subtract 0.2 mm from every reading. After the correction, accuracy improves while precision stays the same, since the spread did not change.
Averaging helps one property, not the other
Taking many readings and averaging them reduces the effect of random error. The mean of many readings is more precise than a single reading. Averaging does nothing to a systematic offset, because the offset is present in every reading and survives the mean.
| Action | Effect on precision | Effect on accuracy |
|---|---|---|
| Take more readings and average | Improves | No change if a systematic error is present |
| Use an instrument with a smaller least count | Improves | No change if the instrument has zero error |
| Correct for zero error | No change | Improves |
| Recalibrate the instrument | Usually no change | Improves |
A stopwatch example with a hidden offset
A stopwatch runs 0.50 s fast over a measured interval. A student times a trolley five times and gets 10.52, 10.51, 10.53, 10.52, 10.52 s. The readings agree to within 0.01 s, so precision is high. If the true time is 10.02 s, each reading is 0.50 s too high, so the result is inaccurate.
The student might report "10.520 s" and feel confident. The digits claim a precision of 0.001 s, but the stopwatch itself may not resolve that finely, and the offset is far larger than the spread. Quoting extra digits creates a false impression of both properties. Report no more digits than the instrument's least count supports.
Common mistakes
- Treating precise as correct. A cluster of equal readings does not prove the value is right. Check for a systematic offset by comparing with a known standard.
- Judging accuracy without a reference. Accuracy needs a true or accepted value. If you have only your own readings, you can assess precision but not accuracy.
- Confusing a single reading with the mean. One reading can land exactly on the true value by luck. A set of such luck-dependent readings may still be imprecise.
- Assuming a finer instrument is always better. A screw gauge with 0.01 mm resolution and an uncorrected zero error of 0.05 mm gives precise but inaccurate readings.
- Mixing up random and systematic error in the cause. Random error mainly degrades precision. Systematic error mainly degrades accuracy.
Summary of the model
- Accuracy is closeness to the true value. Precision is closeness of repeated readings to each other, and it also reflects instrument resolution.
- The two properties are independent, so all four combinations occur.
- Systematic errors reduce accuracy. Random errors reduce precision.
- Averaging improves precision of the mean. Correcting offsets improves accuracy.
- Report digits that reflect the least count, not what a calculator displays.
Exercise
A student measures the diameter of a wire five times with a screw gauge and gets 1.52, 1.52, 1.53, 1.52, 1.52 mm. The accepted diameter is 1.40 mm. Is the set accurate, precise, both, or neither? Suggest one likely cause and say what the student should do.
Show answer
The readings agree within 0.01 mm, so the set is precise. The mean is about 1.52 mm, which is 0.12 mm above 1.40 mm, so the set is not accurate. A likely cause is a positive zero error of about 0.12 mm in the screw gauge. The student should find the zero error with the gauge closed and subtract it from every reading. Taking more readings will not fix it.
Exercise
Dataset P is 4.9, 5.1, 5.0, 5.0 and dataset Q is 5.4, 5.6, 5.5, 5.5, all in cm, for a true length of 5.0 cm. Which dataset has the higher accuracy, and do the two datasets differ in precision?
Show answer
Dataset P has a mean of 5.0 cm, which equals the true value, so P is more accurate. Dataset Q has a mean of 5.5 cm, a bias of +0.5 cm. Both datasets have the same spread (each reading is within 0.1 cm of its mean), so their precision is equal.
Exercise
Which of these actions improves accuracy but not precision: (a) averaging 20 readings instead of 5, (b) replacing a metre scale with a vernier calliper, (c) subtracting a known zero error from every reading?
Show answer
Option (c). Subtracting a known zero error removes a systematic offset, so the readings move toward the true value while their spread stays the same. Option (a) improves precision of the mean. Option (b) improves precision by lowering the least count.