Sub topic 14
Measuring with a multimeter
This chapter assumes you know Ohm's law (V = IR), series and parallel resistor networks, and the voltage divider formula. A digital multimeter (DMM) is a single instrument that works as a voltmeter, an ammeter and an ohmmeter. Each mode connects to the circuit differently, and each disturbs the circuit a little. Most measurement mistakes come from forgetting one of those two facts.
The three connections
The meter's position in the circuit depends on the quantity you measure.
- Voltage is a difference between two points, so the meter goes in parallel with the part you are examining.
- Current is a flow through one path, so the meter goes in series. You must break the circuit and insert it.
- Resistance is measured with the circuit unpowered. The meter supplies its own small test current.
| Quantity | Connection | Circuit state | Main error source |
|---|---|---|---|
| Voltage | Parallel across the part | Powered | Meter input resistance loads the circuit |
| Current | Series, in the path | Powered, loop opened | Burden voltage across the meter |
| Resistance | Across the part | Unpowered, part isolated | Parallel paths, lead resistance |
Measuring voltage
An ideal voltmeter has infinite resistance, so it draws no current. A real DMM has an input resistance, typically 10 MΩ on DC voltage ranges. The meter acts as a 10 MΩ resistor connected in parallel with whatever you probe.
This matters when the circuit's own resistances are large. Take a divider of two 1 MΩ resistors on a 10 V supply. The unloaded output is 5 V. The meter's 10 MΩ appears in parallel with the lower resistor and pulls the output down. The code below computes the size of that error.
def parallel(*resistors):
return 1.0 / sum(1.0 / r for r in resistors)
def divider_out(v_in, r_top, r_bottom):
return v_in * r_bottom / (r_top + r_bottom)
# Voltmeter loading on a high-impedance divider
v_in = 10.0
r_top = 1.0e6
r_bottom = 1.0e6
r_meter = 10.0e6 # typical DMM input resistance on a DC volts range
true_v = divider_out(v_in, r_top, r_bottom)
measured_v = divider_out(v_in, r_top, parallel(r_bottom, r_meter))
error_pct = (measured_v - true_v) / true_v * 100
print(f"true = {true_v:.3f} V, measured = {measured_v:.3f} V, error = {error_pct:.1f} %")
# Ammeter burden on a 5 V, 100 ohm loop
r_load = 100.0
r_ammeter = 0.1 # illustrative meter resistance on a mA range
i_true = 5.0 / r_load
i_measured = 5.0 / (r_load + r_ammeter)
burden_v = i_measured * r_ammeter
print(f"I true = {i_true * 1000:.2f} mA, I measured = {i_measured * 1000:.2f} mA, "
f"burden = {burden_v * 1000:.1f} mV")The first line prints a measured value of 4.762 V, an error of about -4.8 %. The meter did nothing wrong. Your question was "what is the voltage with a 10 MΩ load attached?", and the meter answered that.
A useful rule is that the loading error is roughly the ratio of the circuit's resistance at the probed point to the meter's input resistance. If the circuit resistance is 100 times smaller than the meter's, the error is about 1 %. Low-impedance circuits such as a 12 V battery across a 470 Ω load are effectively unaffected.
Measuring current
To measure current you open the loop, for example by unsoldering one lead or lifting a wire, and put the meter in the gap. The current then flows through the meter. Inside, the current passes through a small shunt resistor, and the meter reads the voltage across it. That shunt is why a current range has a low resistance.
The shunt costs you a burden voltage, which is the current times the meter's resistance. In the code above, a 0.1 Ω meter in a 100 Ω loop reduces the current from 50.00 mA to 49.95 mA, a 0.1 % change. On a 1 Ω loop the same meter would change the current by about 9 %. Check the burden when you measure currents in low-resistance circuits.
You can often avoid breaking the circuit. If a resistor of known value sits in the current path, measure the voltage across it and compute I = V/R. A reading of 2.35 V across a 100 Ω resistor means 23.5 mA. The accuracy is limited by the resistor's tolerance, but nothing has to be opened. A clamp meter is another option. It senses the magnetic field around a wire and does not touch the circuit at all.
Measuring resistance
In resistance mode the meter forces a small known current through the part, measures the resulting voltage, and displays R = V/I. This has several consequences.
- Power must be off. An external voltage adds to the meter's test signal and gives a wrong reading. It can also damage the meter.
- Discharge capacitors first. A charged capacitor acts like a voltage source.
- Isolate the part. A resistor measured while still soldered into a circuit is in parallel with every other path between its two nodes. The reading can only be lower than the true value or equal to it. If a 10 kΩ resistor reads 6.7 kΩ in circuit, lift one lead and measure again.
- Beware of semiconductors. If the meter's test voltage exceeds about 0.6 V, a diode or transistor junction in the circuit may conduct and distort the reading. Many meters have a low-voltage ohms range for this situation.
- Keep your fingers off the probes. Your body adds a resistance in parallel, on the order of 100 kΩ or more. For small resistors this is negligible. For megohm parts it is not.
For low resistances, the leads matter. Test leads add roughly 0.1 to 0.5 Ω in series. Touch the probes together before measuring. Many meters have a relative (REL or ΔREL) mode that subtracts this value. Without that step, a 0.2 Ω reading on a 0.0168 Ω length of copper wire is mostly lead resistance. Precision work on very low resistances uses a four-wire (Kelvin) measurement that separates the current-carrying leads from the voltage-sensing leads.
Reading the specification
A DMM's display is not exact. The datasheet gives accuracy as ±(percentage of reading + counts). A 6000-count meter on its 6 V range has a resolution of 0.001 V. With an accuracy of ±(0.5 % + 2 counts), a reading of 5.000 V has an uncertainty of:
- 0.5 % of 5.000 V = 0.025 V
- 2 counts = 0.002 V
- Total: ±0.027 V, so the true value lies between 4.973 V and 5.027 V
Three practical points follow from this.
- Ranges matter. On a manual-range meter, use the lowest range that does not overflow. The count term is fixed, so a reading near the top of the range gives the best relative accuracy.
- Combine uncertainties. If you compute power as P = V × I from two readings, their percentage errors roughly add. Two 1 % readings give about 2 % on the power.
- Compare with the part's own tolerance. A 1 % resistor measured with a ±0.5 % meter can legitimately read within about 1.5 % of its marked value. A reading further off than that suggests a damaged part or a measurement problem.
Checking readings against Ohm's law
The most useful habit is to cross-check. Measure the voltage across a resistor and the current through it, then verify that V/I matches the resistor's marked value within tolerance. When it does not, work through these causes in order:
- The meter was on the wrong function or range.
- The leads were in the wrong jacks.
- A second path is in parallel with the part, so the part is not isolated.
- The meter loaded the circuit.
- The part is not ohmic, or it heated up and its resistance changed with temperature.
The last cause is common with power resistors and lamps. A filament's resistance when cold can be a tenth of its resistance at operating temperature, so a resistance measurement with the lamp off will not predict the current it draws when lit.
Exercise
A voltage divider uses a 100 kΩ top resistor and a 100 kΩ bottom resistor on a 12 V supply. You measure the output with a DMM whose input resistance is 10 MΩ. What does the meter read, and what is the percentage error? (Hint: replace the bottom resistor with its parallel combination with the meter.)
Show answer
The meter in parallel with the bottom resistor gives 100 kΩ × 10 MΩ / (100 kΩ + 10 MΩ) ≈ 99.0 kΩ. The output is 12 × 99.0 / (100 + 99.0) ≈ 5.970 V. The true unloaded output is 6.000 V, so the error is about -0.5 %.
Exercise
You want to read the current through a load in a 3.3 V circuit. The meter's current range has a burden of 0.2 V at 100 mA full scale, so its resistance is 2 Ω. The load is 33 Ω. What current do you expect with the meter in the loop, and how far is it from the current without the meter?
Show answer
Without the meter, I = 3.3 / 33 = 100 mA. With the meter in series, the total resistance is 35 Ω, so I = 3.3 / 35 ≈ 94.3 mA. The meter lowers the current by about 5.7 %. This is large enough that you should consider measuring the voltage across a known resistor instead.
Exercise
A resistor marked 4.7 kΩ reads 3.1 kΩ when measured while soldered on a powered-off board. Is the resistor damaged? What should you do next?
Show answer
Not necessarily. Other components connected between the same two nodes are in parallel with it, and parallel paths can only lower the reading. Lift one lead of the resistor, or remove it, and measure again. If it then reads close to 4.7 kΩ within its tolerance, the part is good.