Sub topic 10
Conductance as the Reciprocal of Resistance
This chapter assumes you can rearrange equations, use SI prefixes (milli, micro, kilo), and apply V = IR and the series and parallel resistance formulas. You should also know that current is the flow of charge and voltage is energy per unit charge.
Why a second quantity for the same property
Resistance R tells you how strongly a component opposes current. Conductance G tells you how easily it passes current. They describe the same physical property from opposite directions:
G = 1 / R
The SI unit of conductance is the siemens (symbol S). One siemens equals one ampere per volt, which is the same as 1 / ohm. Older texts call this unit the mho (ohm spelled backward) and write it as an inverted omega symbol. You will still see "mho" on old equipment and in some datasheets.
Ohm's law rewritten with conductance reads:
I = G V
Current is proportional to voltage, and G is the constant of proportionality. Nothing new is predicted. The benefit is convenience. Some problems, especially parallel networks, become simple sums when you use G instead of R.
Converting between R and G
Conversion is a single reciprocal in either direction.
| Resistance | Conductance | Notes |
|---|---|---|
| 1 Ω | 1 S | Reference point |
| 100 Ω | 10 mS | 1/100 = 0.01 S |
| 1 kΩ | 1 mS | Common in analog circuits |
| 1 MΩ | 1 µS | Typical of high-impedance inputs |
| 0 Ω (ideal short) | infinite | A perfect wire |
| infinite (open circuit) | 0 S | No current path |
The last two rows show that the reciprocal flips the extremes. A short circuit has zero resistance and unlimited conductance. An open circuit has unlimited resistance and zero conductance. In practice you cannot compute G for a true short because the division by zero is undefined. Real wires always have a small nonzero resistance, as the resistivity chapter showed.
Conductance in parallel networks
In a series connection, resistances add because the same current passes through each element and the voltage drops accumulate. In a parallel connection, every branch sees the same voltage and the branch currents add. Applying I = G V to each branch:
- Branch currents: I₁ = G₁V, I₂ = G₂V, I₃ = G₃V
- Total current: I = I₁ + I₂ + I₃ = (G₁ + G₂ + G₃) V
- So the equivalent conductance is G_eq = G₁ + G₂ + G₃
This is the same rule you already know for parallel resistors, 1/R_eq = 1/R₁ + 1/R₂ + ..., written in a cleaner form. Conductances in parallel add the way resistances in series add. The two cases mirror each other:
| Connection | Quantity that adds directly |
|---|---|
| Series | Resistance |
| Parallel | Conductance |
Adding more parallel branches always increases the total conductance, so the total resistance falls. The equivalent resistance of a parallel group is always smaller than the smallest branch resistance. In conductance terms, this is the obvious fact that a sum of positive numbers is larger than any single term.
A worked example
Three resistors of 100 Ω, 220 Ω, and 330 Ω are connected in parallel across 12 V. Find the equivalent resistance and the total current.
- Convert each to conductance:
- G₁ = 1/100 = 10.00 mS
- G₂ = 1/220 ≈ 4.545 mS
- G₃ = 1/330 ≈ 3.030 mS
- Add: G_eq = 10.00 + 4.545 + 3.030 = 17.575 mS
- Convert back: R_eq = 1 / 0.017575 ≈ 56.9 Ω
- Total current: I = G_eq V = 0.017575 × 12 ≈ 0.211 A
Check the result: 56.9 Ω is smaller than the smallest branch (100 Ω), as it must be. The branch currents are 120 mA, 54.5 mA, and 36.4 mA, which sum to about 211 mA, matching step 4.
You can confirm this in code:
def conductance(r):
return 1.0 / r
def parallel_via_conductance(*resistors):
g_total = sum(conductance(r) for r in resistors)
return 1.0 / g_total
v = 12.0
branches = [100.0, 220.0, 330.0]
g_eq = sum(conductance(r) for r in branches)
r_eq = parallel_via_conductance(*branches)
i_total = g_eq * v
print(f"G_eq = {g_eq * 1000:.3f} mS")
print(f"R_eq = {r_eq:.1f} ohm")
print(f"I = {i_total * 1000:.0f} mA")
for r in branches:
print(f"branch {r:>5.0f} ohm: {conductance(r) * v * 1000:.1f} mA")The output matches the hand calculation: Geq = 17.576 mS (the hand sum of 17.575 differs only by rounding), Req = 56.9 Ω, and I = 211 mA.
Current division with conductance
Conductance gives the cleanest form of the current divider. Because every branch has the same voltage, each branch current is proportional to its own conductance:
Ik = Itotal × Gk / Geq
The branch with the largest conductance, which is the one with the smallest resistance, takes the largest share of the current. In the example above, the 100 Ω branch carries 10.00 / 17.575 ≈ 56.9% of the total current.
For two branches, the conductance form gives the familiar resistance version after substitution:
I₁ = I_total × R₂ / (R₁ + R₂)
Notice that the resistance form is "crossed": the current in branch 1 depends on R₂. The conductance form has no such twist, which makes it easier to remember and less error-prone with three or more branches.
Where conductance appears in practice
Conductance is the more natural quantity in several settings.
- Parallel loads. Adding a load in parallel adds its conductance. Power systems and battery packs are often reasoned about this way.
- Circuit analysis methods. Nodal analysis writes Kirchhoff's current law at each node in terms of conductances, so the coefficient matrix is built from G values. Circuit simulators use this formulation internally.
- Material properties. Conductivity σ is the reciprocal of resistivity ρ, so σ = 1/ρ, in siemens per metre. The conductance of a uniform conductor is G = σA/L, which is just R = ρL/A inverted. Copper, with ρ of about 1.68 × 10⁻⁸ Ω·m, has σ of about 5.95 × 10⁷ S/m.
- Leakage and insulation. Very large resistances are awkward to quote. Leakage through an insulator or a capacitor is often given as a small conductance, such as a few nanosiemens.
- Sensors. Some devices, such as conductivity probes for water quality, report conductance directly, usually in microsiemens.
Edge cases and common mistakes
- Adding resistances in parallel. Adding R values for parallel branches gives a wrong, too-large answer. Convert to G first, or use the reciprocal-sum formula.
- Forgetting the final reciprocal. After summing conductances, you hold Geq. If the question asks for resistance, take 1/Geq. Check that your answer is smaller than the smallest branch.
- Prefix mismatch. Mixing millisiemens with ohms in one expression is a common slip. Convert everything to base units (S and Ω) before combining.
- Applying G = 1/R to non-ohmic parts. For a diode, lamp, or thermistor, the ratio I/V depends on the operating point. You can still define a static conductance I/V at one point, and a differential conductance dI/dV for small changes, but these are different numbers. The simple G = 1/R relation with a constant G holds only for ohmic behavior.
- Treating zero as safe. A branch of 0 Ω has infinite conductance. In a parallel group it shorts out all the others, because the equivalent resistance becomes 0 Ω. Conductance sums make this obvious: one infinite term dominates.
- Temperature. For a metal, R rises with temperature, so G falls. A 100 Ω copper element at 70 °C is about 119.5 Ω (using α ≈ 0.0039 per °C), so its conductance drops from 10.0 mS to about 8.37 mS.
Summary of relations
| Quantity | Symbol | Unit | Relation |
|---|---|---|---|
| Resistance | R | ohm (Ω) | R = V/I = 1/G |
| Conductance | G | siemens (S) | G = I/V = 1/R |
| Resistivity | ρ | Ω·m | R = ρL/A |
| Conductivity | σ | S/m | G = σA/L, σ = 1/ρ |
Exercise
Four resistors of 200 Ω, 200 Ω, 400 Ω, and 1 kΩ are connected in parallel across a 10 V source. Using conductance, find the equivalent resistance and the current through the 400 Ω branch.
Show answer
Conductances: 1/200 = 5 mS (twice, so 10 mS), 1/400 = 2.5 mS, 1/1000 = 1 mS. Geq = 10 + 2.5 + 1 = 13.5 mS. Req = 1/0.0135 ≈ 74.1 Ω, which is below the smallest branch (200 Ω), as expected. The 400 Ω branch current is G V = 0.0025 × 10 = 25 mA.
Exercise
A copper wire has a conductance of 40 S. It is replaced by a wire of the same material and length but with half the cross-sectional area. What is the new conductance, and what is the new resistance?
Show answer
Conductance is G = σA/L, so halving A halves G. The new conductance is 20 S, and the new resistance is 1/20 = 0.05 Ω (the original was 1/40 = 0.025 Ω, so resistance doubles).
Exercise
A leaky capacitor passes a steady 3 µA when 12 V is applied across it. Treating the leakage as an ohmic path, find its conductance in nanosiemens and its resistance in megohms.
Show answer
G = I/V = 3 × 10⁻⁶ / 12 = 0.25 × 10⁻⁶ S = 250 nS. R = 1/G = 1/(250 × 10⁻⁹) = 4 × 10⁶ Ω = 4 MΩ.