Sub topic 14
Poles and zeros of first-order filters
This chapter rewrites the RC and RL filter results in terms of the complex variable s. It shows that two numbers, the pole and the zero, describe the whole frequency response. It assumes you can already derive H(jω) with the voltage divider, convert gain to decibels, find a cutoff frequency, and add complex numbers in polar form.
From jω to s
So far the filters were analyzed at a sinusoidal frequency ω, using impedances jωL and 1/(jωC). The same circuit can be analyzed with the complex frequency s, where the impedances become sL and 1/(sC). The transfer function H(s) is the voltage-divider result written with s in place of jω. Setting s = jω gives back the frequency response you already know.
For the RC low-pass filter with the output across C:
H(s) = (1/(sC)) / (R + 1/(sC)) = 1 / (1 + sRC)
Write ω0 = 1/(RC). Then H(s) = ω0 / (s + ω0).
Every first-order transfer function is a ratio of two polynomials in s. The numerator is at most degree 1, and the denominator is exactly degree 1.
- A zero is a value of s that makes H(s) equal to zero. It is a root of the numerator.
- A pole is a value of s that makes the denominator zero, so H(s) grows without bound. It is a root of the denominator.
For the RC low-pass filter there is no zero in the finite s-plane. The only pole is where 1 + sRC = 0, so s = -1/RC = -ω0.
The four filters in pole-zero form
The same steps give the other three first-order filters.
| Filter | H(s) | Zero | Pole |
|---|---|---|---|
| RC low-pass (out across C) | 1 / (1 + sRC) | none | -1/(RC) |
| RC high-pass (out across R) | sRC / (1 + sRC) | 0 | -1/(RC) |
| RL low-pass (out across R) | R / (R + sL) = (R/L) / (s + R/L) | none | -R/L |
| RL high-pass (out across L) | sL / (R + sL) = s / (s + R/L) | 0 | -R/L |
Three patterns follow from the table:
- Each filter has exactly one pole, and it sits on the negative real axis at s = -ω0. Its distance from the origin is the cutoff angular frequency, so fc = ω0/(2π).
- A low-pass filter has no finite zero. A high-pass filter has a zero at s = 0.
- Swapping the output element between the two parts of the divider moves the zero and leaves the pole where it was. The pole depends only on R, L, and C, not on where you measure the output.
Reading the frequency response from the pole and zero
On the frequency axis, s = jω. The factored form of a first-order function is
H(s) = K (s - z) / (s - p)
where K is a constant. Each factor (jω - p) is a vector from the pole p to the point jω on the imaginary axis. So the magnitude and phase come from simple geometry:
- |H(jω)| = K × (distance from the zero to jω) / (distance from the pole to jω)
- ∠H(jω) = ∠(jω - z) - ∠(jω - p)
Apply this to the low-pass filter, with p = -ω0:
- The distance from the pole to jω is √(ω0² + ω²).
- At ω = 0 this distance is ω0, the minimum.
- At ω = ω0 it is √2 × ω0, so the gain has dropped by a factor √2. That is the -3 dB point.
- For ω much larger than ω0 the distance grows in proportion to ω, so the gain falls by 10 times for every 10 times increase in frequency. That is -20 dB per decade.
- The angle of (jω - p) goes from 0° to 90° as ω goes from 0 to infinity, so the phase of the low-pass filter goes from 0° to -90°, passing through -45° at ω0.
For the high-pass filter the zero at the origin adds a factor ω to the numerator.
- The numerator distance grows in proportion to ω, which gives a +20 dB/decade slope at low frequency.
- Above ω0 the denominator grows at the same rate, so the two cancel and the gain levels off at 0 dB.
- The zero at the origin contributes a constant +90° of phase. The pole subtracts between 0° and 90°, so the high-pass phase goes from +90° down to 0° and passes through +45° at ω0.
The rule that a pole bends the magnitude slope by -20 dB/decade and a zero bends it by +20 dB/decade is the basis of asymptotic Bode plots. The bend happens at the frequency whose magnitude equals the pole or zero location. For a zero at the origin there is no bend, only a line with constant +20 dB/decade slope.
Pole location and the time constant
A pole at s = p corresponds to a term e^(pt) in the circuit's natural (unforced) response. With p = -1/τ this is e^(-t/τ), the familiar exponential decay of an RC or RL circuit. The time constants are τ = RC and τ = L/R. So the pole location gives both views of the circuit:
- Frequency domain: cutoff ω0 = |p| = 1/τ, so fc = 1/(2πτ).
- Time domain: the step response settles with time constant τ = 1/|p|.
A pole farther to the left means a larger bandwidth and a faster response. A pole closer to the origin means a lower cutoff and a slower response. Because a first-order pole is always on the real axis, it never produces oscillation or a peak in the magnitude. Resonant peaks need complex pole pairs, which first-order circuits cannot have.
Loading moves the pole
Source and load resistance are where pole thinking is most useful. You do not need to redo the full divider. Find the resistance that the capacitor (or inductor) sees looking back into the circuit, with the source set to zero. The pole is at -1/(Req C) for a capacitor and -Req/L for an inductor.
For the RC low-pass filter:
- A source resistance Rs adds to R, so the pole moves to -1/((Rs + R)C), which is lower in frequency.
- A load resistance RL across C makes the capacitor see R in parallel with RL, so the pole moves to -1/((R ∥ RL)C), which is higher in frequency. The DC gain also drops from 1 to RL/(R + RL).
For the RC high-pass filter, a load RL in parallel with R changes the output resistor. The pole location stays tied to the capacitor, and the zero stays at s = 0. The cutoff frequency rises, because the capacitor now charges through Rs + (R ∥ RL) and the divider's high-frequency gain falls below 0 dB.
Checking poles and zeros numerically
A transfer function written as polynomial coefficients can be factored with np.roots. The script below does this for the RC low-pass and high-pass filters of the earlier chapters (R = 1.59 kΩ, C = 100 nF). It evaluates H(s) at the pole frequency two ways: from the polynomials, and from the factored pole-zero form.
import numpy as np
R = 1.59e3
C = 100e-9
RC = R * C
filters = {
"RC low-pass": ([1.0], [RC, 1.0]),
"RC high-pass": ([RC, 0.0], [RC, 1.0]),
}
f = 1 / (2 * np.pi * RC)
s = 2j * np.pi * f
for name, (num, den) in filters.items():
zeros = np.roots(num)
poles = np.roots(den)
k = num[0] / den[0]
h_poly = np.polyval(num, s) / np.polyval(den, s)
h_pz = k * np.prod(s - zeros) / np.prod(s - poles)
print(name)
print(" zeros:", zeros, " poles:", poles)
print(f" pole frequency = {abs(poles[0]) / (2 * np.pi):.1f} Hz")
print(f" |H| = {20 * np.log10(abs(h_poly)):.2f} dB, "
f"phase = {np.degrees(np.angle(h_poly)):.2f} deg")
print(" same from poles and zeros:", np.isclose(h_poly, h_pz))Both filters report a pole near -6290 rad/s, which is about 1001 Hz. At that frequency the low-pass gain is about -3.01 dB with -45° of phase, and the high-pass gain is about -3.01 dB with +45° of phase. The low-pass zero list is empty, and the high-pass zero list contains 0. The last line of each block prints True, which confirms that the factored form K(s - z)/(s - p) reproduces the polynomial form.
Common errors
- Placing the zero at the wrong place. The high-pass zero is at s = 0, not at the cutoff frequency. The cutoff comes from the pole.
- Treating the pole as the only frequency in the filter. The zero at the origin is also part of the response. It sets the +20 dB/decade rise and the +90° phase.
- Forgetting that the bend is only an asymptote. At the pole frequency the true magnitude is 3 dB below the asymptote intersection, and the true phase is exactly 45° from its limits.
- Reading a loaded filter's pole from the unloaded R and C. Use the resistance the capacitor or inductor actually sees.
- Mixing signs. Poles of passive RC and RL circuits are always at negative real s. A positive real part would mean a response that grows without limit, which passive first-order circuits cannot produce.
Exercise
An RL high-pass filter has R = 62.8 Ω and L = 10 mH, with the output across L. Write H(s), give the pole and the zero, and find the cutoff frequency in hertz.
Show answer
H(s) = sL / (R + sL) = s / (s + R/L). The zero is at s = 0. The pole is at s = -R/L = -62.8 / 0.010 = -6280 rad/s. The cutoff frequency is fc = 6280 / (2π) ≈ 1000 Hz.
Exercise
An RC low-pass filter with R = 1.59 kΩ and C = 100 nF is driven by a source with Rs = 410 Ω. Where does the pole move, in hertz? What is its time constant?
Show answer
The capacitor now sees Rs + R = 2.0 kΩ. The time constant is τ = 2000 × 100 nF = 200 µs, so the pole is at s = -5000 rad/s. The cutoff is fc = 5000 / (2π) ≈ 796 Hz, lower than the unloaded value of about 1001 Hz.
Exercise
The same RC low-pass filter (R = 1.59 kΩ, C = 100 nF) drives a load RL = 1.59 kΩ across the capacitor. What are the DC gain and the new cutoff frequency?
Show answer
The DC gain is RL / (R + RL) = 0.5, which is -6.02 dB. The capacitor sees R ∥ RL = 795 Ω, so τ = 795 × 100 nF = 79.5 µs. The pole is at -12 580 rad/s, so fc ≈ 2002 Hz.