Sub topic 7
Asymptotes and Roll-off on a Bode Plot
This chapter assumes you can write the transfer function of a first-order filter, convert a gain to decibels, and find the cutoff frequency. You will use those three skills to sketch a Bode plot by hand. You will also learn where the sketch is wrong and by how much.
Why asymptotes are worth learning
A first-order filter has a transfer function with one frequency-dependent term. Far from the cutoff frequency, that term is either very small or very large compared with 1. The magnitude then simplifies to a power of frequency, and on log-log axes a power of frequency is a straight line.
An asymptotic Bode plot replaces the true curve with straight line segments. You can draw it from the cutoff frequency and the passband gain, with no calculator. It is accurate enough to check a design, spot a wrong component value, or read a measured plot.
Deriving the magnitude asymptotes
Take the RC low-pass filter with the output across the capacitor:
H(jω) = 1 / (1 + jω/ωc), with ωc = 1/(RC)
The magnitude is |H| = 1 / sqrt(1 + (ω/ωc)²). There are two limits.
- Well below cutoff (ω much less than ωc). The term (ω/ωc)² is negligible, so |H| ≈ 1 and the gain is 0 dB. This is the low-frequency asymptote, a horizontal line.
- Well above cutoff (ω much greater than ωc). The 1 under the square root is negligible, so |H| ≈ ωc/ω. In decibels this is 20·log10(ωc/ω) = −20·log10(ω/ωc).
The second result is the roll-off. Every time ω is multiplied by 10, the log term increases by 1, so the gain falls by 20 dB. The high-frequency asymptote is a straight line with a slope of −20 dB per decade. Because doubling the frequency adds 20·log10(2), about 6.02 dB, of attenuation, the same slope is also written as −6 dB per octave.
The two asymptotes meet at ω = ωc, where ω/ωc = 1 and both expressions give 0 dB. That meeting point is called the corner frequency or break frequency. For a first-order filter it is the same as the cutoff frequency.
The error at the corner
The asymptotes are exact only in the limits. The largest error is at the corner. At ω = ωc the true magnitude is 1/sqrt(2), which is −3.01 dB, while the asymptotes say 0 dB. The sketch therefore overestimates the gain by about 3 dB at the corner.
The error shrinks quickly on each side. The table compares the true gain of a low-pass filter with the asymptotic value.
| ω/ωc | True gain (dB) | Asymptotic gain (dB) | Error (dB) |
|---|---|---|---|
| 0.1 | −0.04 | 0 | 0.04 |
| 0.5 | −0.97 | 0 | 0.97 |
| 1 | −3.01 | 0 | 3.01 |
| 2 | −6.99 | −6.02 | 0.97 |
| 10 | −20.04 | −20 | 0.04 |
The error is symmetric about the corner on a log axis. It is about 1 dB half a decade-fraction away (a factor of 2 in frequency) and under 0.05 dB one decade away. For most sketches you can draw the lines and then mark the −3 dB point at the corner.
Phase asymptotes
The phase of the low-pass filter is φ = −arctan(ω/ωc). Its limits are simple:
- Well below cutoff, φ approaches 0°.
- At cutoff, φ = −45° exactly.
- Well above cutoff, φ approaches −90°.
The phase curve does not have a sharp corner, so the usual straight-line approximation uses three segments. Hold 0° until one-tenth of the corner frequency (0.1·ωc). Draw a line of −45° per decade from 0.1·ωc to 10·ωc. Hold −90° above that. This line passes through −45° at ωc, matching the exact value.
The approximation is not as tight as the magnitude one. The maximum error is about 5.7°, which occurs at 0.1·ωc and 10·ωc. Use it to see the trend. Do not use it when a design depends on the phase to within a few degrees. In that case, evaluate the arctangent.
Reading the high-pass filter
The high-pass filter is the mirror image. For the RC high-pass with the output across the resistor:
H(jω) = (jω/ωc) / (1 + jω/ωc)
Well below cutoff the numerator dominates the change, so |H| ≈ ω/ωc. In decibels this is +20·log10(ω/ωc), a line rising at +20 dB per decade. Well above cutoff, |H| approaches 1 and the gain is 0 dB. The two asymptotes again meet at ωc, and the true gain at the corner is −3 dB.
The phase runs from +90° at low frequency, through +45° at ωc, to 0° at high frequency. The same ±45° per decade rule applies, with the sign reversed.
The RL filters follow the same pattern. Only the formula for ωc changes. For the RL circuit, ωc = R/L.
A worked sketch
Consider the RC low-pass filter with R = 1.59 kΩ and C = 100 nF. The cutoff frequency is
fc = 1 / (2π · 1590 · 100×10⁻⁹) ≈ 1.00 kHz
To sketch the magnitude plot:
- Draw a horizontal line at 0 dB from the left edge to 1 kHz.
- From the point (1 kHz, 0 dB), draw a line going down to the right at −20 dB per decade. It reaches −20 dB at 10 kHz and −40 dB at 100 kHz.
- Mark the true curve at 1 kHz as −3 dB, and join it smoothly to the two lines.
To read a value from the sketch at 5 kHz, count the distance in decades: log10(5) ≈ 0.70 decades above the corner. The asymptotic gain is −20 × 0.70 = −14 dB. The exact value is −14.2 dB, so the sketch is close.
Checking the asymptote numerically
The script below compares the exact magnitude with the asymptotic one over several frequencies. It also reports the error.
import numpy as np
R = 1.59e3 # ohms
C = 100e-9 # farads
fc = 1 / (2 * np.pi * R * C)
f = fc * np.array([0.1, 0.5, 1, 2, 5, 10, 100])
w = 2 * np.pi * f
H = 1 / (1 + 1j * w * R * C)
exact_db = 20 * np.log10(np.abs(H))
asym_db = np.where(f < fc, 0.0, -20 * np.log10(f / fc))
phase = np.degrees(np.angle(H))
print(f"fc = {fc:.1f} Hz")
for fi, e, a, p in zip(f, exact_db, asym_db, phase):
print(f"{fi:9.1f} Hz exact {e:7.2f} dB asym {a:7.2f} dB "
f"error {a - e:5.2f} dB phase {p:7.2f} deg")The printed error peaks at 3.01 dB at the corner and falls to about 0.04 dB at one decade away on either side. The phase column shows −45° at fc, as the derivation predicts.
Common errors
- Confusing the roll-off with the level. The slope of −20 dB per decade says how fast the gain falls. It does not say where the line sits. The line is fixed by the requirement that it passes through 0 dB at the corner (for a passband gain of 1).
- Reading the −3 dB point off the asymptotes. The straight-line sketch shows 0 dB at the corner. The −3 dB value belongs to the true curve. Add it by hand.
- Mixing octave and decade. −20 dB per decade is −6 dB per octave. Using the wrong unit gives a threefold error on a hand estimate.
- Using Hz and rad/s together. The corner is at fc in hertz or ωc in radians per second. The ratio ω/ωc equals f/fc, but mixing the two inside one ratio is wrong by a factor of 2π.
- Assuming a steeper roll-off than the circuit has. A single RC or RL stage never rolls off faster than −20 dB per decade. A steeper slope in a measurement indicates more than one stage, or a loading effect.
- Forgetting the passband gain. If the circuit has a gain other than 1 in its passband, shift the whole plot by that gain in dB. The slope is unchanged.
Using the asymptotes in reverse
You can also read a measured Bode plot. Find the point where the flat line meets the sloping line. That gives fc. If the sloping part has −20 dB per decade, a single first-order stage explains it. A slope near −40 dB per decade points to two stages. A real measurement flattens at very high frequency, for example because of stray capacitance or the limits of the instrument. Use the portion of the plot that follows the straight line.
Exercise
An RL high-pass filter has R = 100 Ω and L = 16 mH, with the output across the inductor. (a) Find the corner frequency. (b) Using asymptotes, what is the gain at 100 Hz? (c) What is the true gain at the corner, and what is the phase there?
Show answer
(a) fc = R / (2πL) = 100 / (2π × 0.016) ≈ 995 Hz, so about 1 kHz. (b) 100 Hz is one decade below the corner. The high-pass asymptote rises at +20 dB per decade, so the gain is 0 dB − 20 dB = −20 dB. (c) At the corner the true gain is −3 dB (a magnitude of 0.707). The phase is +45°.
Exercise
A measured low-pass response is flat at 0 dB up to about 2 kHz, then falls to −26 dB at 40 kHz. Is this consistent with a single first-order stage with a corner at 2 kHz?
Show answer
The ratio 40 kHz / 2 kHz = 20, which is log10(20) ≈ 1.30 decades. A first-order stage gives about −20 × 1.30 = −26 dB. The measurement matches a single first-order stage with its corner at 2 kHz.