Sub topic 5
Cutoff frequency and the -3 dB point
This chapter assumes you can write the transfer function of a first-order RC or RL circuit as a voltage divider, H(jω), and that you are comfortable with complex magnitude and angle and with decibels. Here you define the cutoff frequency, derive it from the transfer function, and learn why it sits at -3 dB.
What the cutoff frequency means
A first-order filter does not switch from passing to blocking at one frequency. Its gain changes smoothly. The cutoff frequency fc (also called the corner frequency, break frequency, or -3 dB frequency) is the conventional marker for where that change happens.
It is defined by one condition: the output magnitude has fallen to 1/√2 ≈ 0.7071 of its passband value. Equivalently, the output power has fallen to half, because power goes with the square of voltage:
(1/√2)² = 1/2
In decibels, the gain at fc is 20·log10(1/√2) = -3.0103 dB, which is why the point is called the -3 dB point.
Deriving fc for the RC low-pass filter
Take the RC low-pass filter with the output across the capacitor. The voltage divider gives:
H(jω) = (1/jωC) / (R + 1/jωC) = 1 / (1 + jωRC)
Define ωc = 1/(RC). Then:
H(jω) = 1 / (1 + j·ω/ωc)
The magnitude and phase are:
- |H(jω)| = 1 / √(1 + (ω/ωc)²)
- ∠H(jω) = -arctan(ω/ωc)
Set |H| = 1/√2 and solve:
1 / √(1 + (ω/ωc)²) = 1/√2
so 1 + (ω/ωc)² = 2, which gives ω = ωc. The -3 dB condition is met exactly when the real and imaginary parts of the denominator are equal, 1 = ω/ωc. At that frequency the phase is -arctan(1) = -45°.
Converting to hertz with ω = 2πf:
fc = 1 / (2πRC)
For R = 1.59 kΩ and C = 100 nF:
fc = 1 / (2π · 1.59×10³ · 100×10⁻⁹) ≈ 1001 Hz
The general rule: find where the two denominator terms match
You do not need to memorize a formula for every circuit. Write H(jω) in the standard form 1/(1 + jω/ωc) for a low-pass filter, or (jω/ωc)/(1 + jω/ωc) for a high-pass filter. Then ωc is the value that makes the "jω/ωc" term equal to 1. Each first-order circuit follows from this.
| Circuit | Output taken across | fc |
|---|---|---|
| RC low-pass | C | 1 / (2πRC) |
| RC high-pass | R | 1 / (2πRC) |
| RL low-pass | R | R / (2πL) |
| RL high-pass | L | R / (2πL) |
The low-pass and high-pass versions of the same R and C (or R and L) share one cutoff frequency. They differ in which side of fc they pass.
Gain at multiples of fc
Because |H| depends only on the ratio f/fc, one table covers every first-order low-pass filter. For a high-pass filter, the magnitudes are the same at the reciprocal ratios (the high-pass gain at 2·fc equals the low-pass gain at fc/2), and the phase differs.
| f / fc | Column | H | (low-pass) | Gain (dB) | Phase (degrees) |
|---|---|---|---|---|---|
| 0.1 | 0.995 | -0.04 | -5.71 | ||
| 0.5 | 0.894 | -0.97 | -26.57 | ||
| 1 | 0.707 | -3.01 | -45.00 | ||
| 2 | 0.447 | -6.99 | -63.43 | ||
| 10 | 0.0995 | -20.04 | -84.29 |
Two observations follow from the table. First, the filter is already about 1 dB down at half the cutoff frequency, so the passband is not flat right up to fc. Second, one decade above fc the gain is almost exactly -20 dB, which is the beginning of the -20 dB/decade roll-off covered in a later chapter.
Solving for a frequency at a given gain
Sometimes the question is reversed: at what frequency does the gain drop to some value k (as a ratio)? Rearrange the magnitude equation for the low-pass filter:
f = fc · √(1/k² - 1)
For a -1 dB point, k = 10^(-1/20) = 0.8913, so f = fc · √(1.2589 - 1) = 0.509·fc. A filter with fc = 1061 Hz is therefore 1 dB down at about 540 Hz. You can check the formula with k = 0.7071: 1/k² = 2, so f = fc.
Computing the -3 dB point numerically
A script is a useful check on your algebra. The program below sweeps the RC low-pass filter, finds the frequency where the gain crosses -3.0103 dB by interpolation, and compares it with the formula.
import numpy as np
R = 1.59e3 # ohms
C = 100e-9 # farads
fc_formula = 1 / (2 * np.pi * R * C)
f = np.logspace(1, 5, 100001) # 10 Hz to 100 kHz
w = 2 * np.pi * f
H = 1 / (1 + 1j * w * R * C)
mag_db = 20 * np.log10(np.abs(H))
phase_deg = np.degrees(np.angle(H))
target_db = 20 * np.log10(1 / np.sqrt(2)) # -3.0103 dB
# np.interp needs increasing x values, and mag_db decreases with f,
# so both arrays are reversed.
fc_numeric = np.interp(target_db, mag_db[::-1], f[::-1])
phase_at_fc = np.interp(fc_numeric, f, phase_deg)
print(f"target gain = {target_db:.4f} dB")
print(f"fc (formula) = {fc_formula:.2f} Hz")
print(f"fc (numeric) = {fc_numeric:.2f} Hz")
print(f"phase at fc = {phase_at_fc:.2f} deg")The two frequencies should agree to within a fraction of a hertz, and the phase should be very close to -45°. If they disagree by a factor near 6.28, you have used 1/(RC) where you needed 1/(2πRC).
Why -3 dB rather than another threshold
The 3 dB convention has a physical basis. At fc, a resistor and a capacitor (or inductor) in a first-order filter have equal impedance magnitudes: R = 1/(ωC) for the RC case, or R = ωL for the RL case. The reactive and resistive parts then split the signal's power equally. Total power in the circuit is shared evenly, and the output power is half its passband value.
For a low-pass filter, fc is also the filter's bandwidth: the range from 0 Hz to fc over which the gain stays within 3 dB of its DC value. A high-pass filter has no upper edge, so its fc marks the lower edge of its passband.
Common errors
- Treating -3 dB as half the voltage. Half the voltage is -6.02 dB. The -3 dB point is half the power, or 70.7% of the voltage.
- Expecting a sharp edge. At fc the signal still passes at 70.7%. Signals at 0.5·fc are attenuated by almost 1 dB, and signals at 2·fc are not removed, only reduced to 44.7%.
- Mixing units. Using ωc in rad/s where a frequency in hertz is expected, or the reverse, gives results off by 2π.
- Ignoring source and load. The formula applies to an ideal source and an open-circuit output. A source resistance Rs adds to R in the low-pass case, and a load resistance RL in parallel with C changes both the passband gain and fc. A later chapter covers these effects. If a measured fc disagrees with your calculation, check this first.
- Measuring the -3 dB point from the wrong reference. The passband level is the reference. If the passband gain is already -2 dB because of loading, the cutoff is where the gain is -5 dB, not -3 dB.
- Using tolerances carelessly. Capacitors are often 10% or 20% parts, so a computed 1001 Hz might measure anywhere from about 830 Hz to 1250 Hz. Treat fc as a design value with a tolerance.
Exercises
Exercise
An RC low-pass filter uses R = 10 kΩ and C = 15 nF. Find fc in hertz. Then find the frequency at which the gain is -1 dB.
Show answer
fc = 1 / (2π · 10×10³ · 15×10⁻⁹) = 1 / (9.425×10⁻⁴) ≈ 1061 Hz. For a -1 dB gain, k = 10^(-1/20) = 0.8913, so f = fc · √(1/k² - 1) = 1061 · √(1.2589 - 1) = 1061 · 0.5088 ≈ 540 Hz.
Exercise
A student measures an output voltage that is exactly half the passband voltage and says the signal is at the cutoff frequency. What gain in dB did the student measure, and is the signal above or below fc for a low-pass filter?
Show answer
A voltage ratio of 0.5 is 20·log10(0.5) = -6.02 dB. The cutoff gain is -3.01 dB, so the signal is beyond the cutoff. For a first-order low-pass filter, 0.5 = 1/√(1 + (f/fc)²) gives f/fc = √3 ≈ 1.73, so the signal is at about 1.73·fc, with a phase of about -60°.