Sub topic 15
Potentiometer and Resonance Tube Experiments
Prerequisites: You should know potential difference, emf, resistance, Ohm’s law, wave speed, and basic error propagation.
Comparing EMFs with a potentiometer
A potentiometer measures potential difference by comparing it with the potential drop along a uniform resistance wire. If a constant current flows through the wire, the potential gradient is constant. Therefore, the potential drop is proportional to the balancing length.
At the null point, the galvanometer shows zero deflection. The source being measured supplies no current, so its internal resistance does not affect the comparison.
For two cells with emfs E₁ and E₂, let l₁ and l₂ be their balancing lengths:
E₁ / E₂ = l₁ / l₂
The comparison is accurate because both cells are measured using the same potential gradient.
Finding internal resistance
First connect the cell without an external load. Its emf E balances against length l₁. Then connect a known resistance R across the cell. The terminal potential difference V balances against length l₂.
Since potential drop is proportional to balancing length,
E / V = l₁ / l₂
For a cell of internal resistance r,
V = ER / (R + r)
Combining these equations gives
r = R(E / V - 1) = R(l₁ / l₂ - 1)
or
r = R(l₁ - l₂) / l₂
The loaded balancing length is smaller because some potential is lost inside the cell.
| Measurement | Balance length | Meaning |
|---|---|---|
| Cell without load | l₁ | emf E |
| Cell with resistance R | l₂ | terminal voltage V |
Speed of sound by resonance tube
A resonance tube is closed at one end and contains an adjustable length of air. When the air-column length matches an odd quarter-wavelength, resonance occurs:
L + e = (2n - 1)λ / 4
Here, e is the end correction, λ is wavelength, and n is a positive integer. End correction accounts for the fact that the air vibrates slightly beyond the tube opening.
For the first two resonances,
L₁ + e = λ / 4
L₂ + e = 3λ / 4
Subtracting eliminates the end correction:
λ = 2(L₂ - L₁)
If the tuning fork frequency is f, the speed of sound is
v = fλ = 2f(L₂ - L₁)
The end correction can then be found from
e = (L₂ - 3L₁) / 2
Taking several resonance readings and averaging successive differences reduces random error. Common errors include misidentifying the loudest sound, reading the water level at an angle, and using an inaccurate tuning-fork frequency.
Exercise
A cell gives balance lengths 80 cm without load and 64 cm with a 4 Ω resistance. Find its internal resistance.
Show answer
r = R(l₁ - l₂)/l₂ = 4(80 - 64)/64 = 1 Ω.