Sub topic 16
Focal Length and Refractive Index Experiments
Assume you know the Cartesian sign convention, the lens formula, basic trigonometry, and percentage-error propagation. In these experiments, the main task is to connect a measured distance or angle to a physical constant while controlling alignment and reading errors.
Finding the focal length of a convex lens
For a thin convex lens,
\[ \frac{1}{f}=\frac{1}{v}-\frac{1}{u} \]
where \(u\) is the object distance, \(v\) is the image distance, and \(f\) is the focal length. Using magnitudes for a real object and a real image,
\[ f=\frac{uv}{u+v}. \]
Place the illuminated object, lens, and screen on the same principal axis. Move the screen until the image is sharp. Measure \(u\) and \(v\) from the optical centre of the lens, not from its edge.
A better method uses two sharp-image positions. If the object-screen distance is \(D\), and the separation between the two lens positions is \(d\),
\[ f=\frac{D^2-d^2}{4D}. \]
This displacement method reduces the effect of judging one particular image position.
Finding refractive index with a prism
For a prism of angle \(A\), measure the angle of minimum deviation \(D_m\). At minimum deviation, the light path through the prism is symmetric, so the angle of incidence equals the angle of emergence. The refractive index is
\[ \mu=\frac{\sin\left(\frac{A+D_m}{2}\right)} {\sin\left(\frac{A}{2}\right)}. \]
Rotate the prism gradually and record the deviation. The minimum value is used, not the deviation at an arbitrary setting.
| Quantity | Main reading error | Useful precaution |
|---|---|---|
| \(u,v,D,d\) | Scale least count and parallax | Read at eye level from fixed reference marks |
| \(A,D_m\) | Protractor or spectrometer least count | Take both telescope positions and average |
Common errors and uncertainty
Do not measure lens distances from the wrong reference point. A blurred image introduces random uncertainty, while poor leveling causes a systematic shift. Repeat readings and average them, but averaging cannot remove a systematic error.
For the lens formula, calculate \(f\) for every trial and report the mean. For the prism formula, small angle errors affect the sine terms, so use the instrument’s angular least count and retain sensible significant figures.
Exercise
A lens experiment gives D = 100 cm and d = 60 cm. Find the focal length.
Show answer
f = (D² − d²)/(4D) = (10000 − 3600)/400 = 16 cm.