Sub topic 19
Surface tension and viscosity experiments
Prerequisites and scope
This chapter assumes you can read a screw gauge and a vernier caliper, apply zero correction, and propagate errors through products, quotients and powers. It covers two standard experiments: surface tension by capillary rise, and viscosity by Stokes' law with a falling sphere. Both are mainly error-propagation problems with one or two dominant terms.
Surface tension by capillary rise
Principle
When a clean glass capillary of inner radius r is dipped in water, the liquid rises to a height h above the free surface. The upward force from surface tension balances the weight of the raised column. For a contact angle θ:
T · 2πr cos θ = (π r² h) ρ g
For water on clean glass, θ ≈ 0, so cos θ ≈ 1 and:
T = r h ρ g / 2
Here ρ is the liquid density and g is the acceleration due to gravity. The height h is measured from the free surface in the wide vessel to the bottom of the meniscus. Strictly, the liquid in the meniscus above that point adds a correction of r/3, so a more accurate form is T = (r ρ g / 2)(h + r/3). JEE questions normally ignore this term unless the question mentions it.
Measuring r and h
- The inner radius r is small, so it is found with a travelling microscope. You measure the diameter d of the bore at the top end, in two perpendicular directions, and take the mean. Then r = d/2.
- The height h is measured with the same microscope (or a vernier scale). Focus on the bottom of the meniscus, note the reading, then focus on the free surface in the wide vessel (or on the tip of a pin touching it) and note the second reading. The difference is h.
- Because h is a difference of two readings, its absolute error is the sum of the two least counts. If each reading has error 0.001 cm, then Δh = 0.002 cm.
Error in T
Since T ∝ r h (with ρ and g treated as exact):
ΔT/T = Δr/r + Δh/h
The radius is usually the weaker measurement because r is small. A bore of 0.5 mm radius measured to 0.01 mm gives 2% error in r alone. Water rises about 3 cm in such a tube, so a 0.002 cm error in h contributes only about 0.07%. The radius dominates.
Sources of error
- Dirt or grease changes the contact angle, so the assumption cos θ = 1 fails. This is a systematic error. Clean the tube with chromic acid or a strong detergent, then rinse with distilled water.
- The capillary must be vertical. A tilted tube makes the measured vertical h differ from the length along the tube.
- The bore may not be uniform. Measuring the diameter at the level of the meniscus is better than measuring it at the end.
- Temperature changes T. Surface tension falls as temperature rises, so record the room temperature.
Viscosity by Stokes' law
Principle
A small sphere of radius r falling through a viscous liquid reaches a constant terminal velocity v when the weight balances the buoyant force plus the viscous drag. The drag is given by Stokes' law, F = 6π η r v. The balance gives:
(4/3) π r³ (ρ − σ) g = 6π η r v
where ρ is the density of the sphere and σ is the density of the liquid. Solving for the coefficient of viscosity η:
η = 2 r² (ρ − σ) g / (9 v)
The terminal velocity is found from v = s/t, where s is the distance between two marks (both well below the surface, so the sphere has already stopped accelerating) and t is the time to cover it.
Procedure
- Measure the diameter of several steel balls with a screw gauge, apply zero correction, and take the mean radius.
- Mark two levels on the tall jar, the upper one a few centimetres below the liquid surface.
- Drop a ball gently along the axis of the jar and time the fall between the marks with a stopwatch.
- Repeat with each ball and use the mean time.
Error in η
The radius appears squared and v is a ratio, so:
Δη/η = 2 Δr/r + Δs/s + Δt/t + Δ(ρ − σ)/(ρ − σ)
The factor 2 on Δr/r makes the radius important again. The stopwatch error Δt is usually 0.1 s or more (human reaction time is larger than the instrument least count). A short fall time therefore gives a large Δt/t. Using a longer distance s increases t and reduces that term.
The program below computes η and its relative error from sample data.
import math
g = 9.8 # m/s^2
r, dr = 1.0e-3, 0.01e-3 # sphere radius and its error, m
rho, sigma = 7800.0, 1260.0 # steel and glycerine densities, kg/m^3
s, ds = 0.400, 0.001 # fall distance and its error, m
t, dt = 4.0, 0.1 # fall time and its error, s
v = s / t
eta = 2 * r**2 * (rho - sigma) * g / (9 * v)
rel = 2 * dr / r + ds / s + dt / t # density error neglected
print(f"v = {v:.3f} m/s")
print(f"eta = {eta:.3f} Pa s, relative error = {100 * rel:.1f}%")With these values the terms are 2% from the radius, 0.25% from s and 2.5% from t, so the timing is the largest contributor.
Sources of error and conditions
- Stokes' law holds only for a slow, steady, laminar fall. The ball must reach terminal velocity before the first mark.
- The jar must be much wider than the ball. In a narrow jar the walls add extra drag, and the measured η comes out too high.
- Air bubbles on the ball reduce its effective weight.
- Viscosity depends strongly on temperature, so the liquid must be at a steady temperature.
Comparing the two experiments
| Feature | Capillary rise | Falling sphere |
|---|---|---|
| Quantity found | Surface tension T | Viscosity η |
| Formula | T = r h ρ g / 2 | η = 2 r² (ρ − σ) g / (9 v) |
| Power of r | 1 | 2 |
| Instrument for r | Travelling microscope | Screw gauge |
| Typical dominant error | Radius of bore | Fall time or radius |
| Main systematic error | Dirty tube, tilt | Wall effect, no terminal velocity |
Traps in JEE questions
- Wrong power. In the viscosity formula, r enters as r² in the numerator, so its relative error is doubled.
- Difference of densities. The term (ρ − σ) is a difference, so add the absolute errors of ρ and σ before dividing by (ρ − σ). Do not add relative errors of ρ and σ.
- Diameter versus radius. If the instrument measures diameter d, then Δr/r = Δd/d. Halving does not change the relative error.
- Maximum error. Errors are added, never subtracted, even when a quantity is in the denominator.
- Direction of a systematic error. An unclean tube raises the contact angle, so cos θ falls and the measured h is smaller than expected. A tilted tube gives a longer length along the tube than the true vertical h.
Exercise
A steel ball of radius 2.00 mm, measured to ±0.02 mm, falls through a distance of 0.50 m, measured to ±0.005 m, in 5.0 s, measured to ±0.1 s. Ignoring errors in the densities, find the percentage error in the viscosity η.
Show answer
Δη/η = 2(Δr/r) + Δs/s + Δt/t = 2(0.02/2.00) + 0.005/0.50 + 0.1/5.0 = 0.02 + 0.01 + 0.02 = 0.05. The percentage error in η is 5%.
Exercise
In a capillary rise experiment, the bore diameter is 1.00 mm ± 0.01 mm and the rise is 2.80 cm ± 0.01 cm. Which measurement contributes more to the percentage error in T, and by how much in each case?
Show answer
Since T ∝ r h, the diameter gives Δr/r = Δd/d = 0.01/1.00 = 1.0%. The height gives Δh/h = 0.01/2.80 ≈ 0.36%. The diameter contributes more, about 1.0% against 0.36%, and the total is about 1.4%.