Sub topic 16
Potentiometer: comparing EMFs and finding internal resistance
This chapter assumes you can apply Ohm's law and Kirchhoff's rules, know what EMF and internal resistance are, and can propagate errors through quotients (covered in earlier chapters). The potentiometer is a null-method instrument. It compares potential differences without drawing current from the cell under test, so it measures a cell's true EMF, which a voltmeter cannot do.
Working principle
A potentiometer is a long uniform wire, usually 10 m, with a steady driver cell sending constant current through it. Because the wire is uniform and the current is constant, the potential drop is proportional to length. The drop per unit length is the potential gradient:
k = I·ρ/A = (V_wire)/L
where ρ is the resistivity and A the cross-section of the wire. A cell of EMF E is connected so its positive terminal goes to the end of the wire at higher potential. A galvanometer is connected through a jockey. When the jockey touches the wire at the balance length l, the galvanometer shows zero deflection. At that point no current flows through the cell, so
E = k·l
Because the cell supplies no current at balance, its internal resistance causes no drop, and the measured value is the true EMF.
Conditions for a valid balance
- The driver cell EMF must be larger than the EMF being measured, or no balance point exists on the wire.
- The positive terminals of the driver and test cells must connect to the same end of the wire. If they are reversed, the galvanometer deflects the same way wherever the jockey touches.
- The driver current must stay constant during the experiment, so k stays constant.
- The wire must be uniform, so potential drop is proportional to length.
Comparing two EMFs
Connect cell 1 and find its balance length l₁. Then connect cell 2 using the two-way key and find l₂. Since k is the same,
E₁/E₂ = l₁/l₂
The gradient k cancels, so you do not need to know it. You only need k to be constant between the two readings.
For the error, a quotient of two lengths gives
Δ(E₁/E₂)/(E₁/E₂) = Δl₁/l₁ + Δl₂/l₂
Each length is read with a least count of 1 mm (or 0.1 cm). The relative error is smaller when the balance lengths are large, so choose a rheostat setting that gives long balance lengths (for example, 500 cm rather than 50 cm).
Internal resistance of a cell
Connect a resistance box R across the cell and close the key. The cell now delivers current I, so its terminal potential difference falls below E.
- With the key open (no current drawn from the cell), find the balance length l₁. This gives E = k·l₁.
- Close the key with a known R across the cell and find the new balance length l₂. This gives the terminal voltage V = k·l₂.
With internal resistance r, the current is I = E/(R + r) and V = IR. So
E/V = (R + r)/R, which gives l₁/l₂ = (R + r)/R
Solving for r:
r = R·(l₁ − l₂)/l₂
def internal_resistance(R_ohm, l1_cm, l2_cm):
"""r = R (l1 - l2) / l2 from potentiometer balance lengths."""
return R_ohm * (l1_cm - l2_cm) / l2_cm
# Open circuit balance 500.0 cm, with R = 10 ohm shunted: 400.0 cm
r = internal_resistance(10.0, 500.0, 400.0)
print(f"r = {r:.2f} ohm")This prints r = 2.50 ohm.
Error in r
The quantity (l₁ − l₂) is a difference, so its absolute errors add: Δ(l₁ − l₂) = Δl₁ + Δl₂. The relative error in r is therefore
Δr/r = ΔR/R + (Δl₁ + Δl₂)/(l₁ − l₂) + Δl₂/l₂
The middle term dominates when l₁ and l₂ are close. If R is much larger than r, the two balance lengths nearly match and the difference is a small number with the same absolute error. To keep this term small, choose R of the same order as r so the lengths differ clearly.
Potentiometer versus voltmeter
| Feature | Potentiometer | Voltmeter |
|---|---|---|
| Current drawn from cell at measurement | Zero at balance | Small but nonzero |
| Reading of EMF | True EMF | Terminal voltage, slightly below E |
| Sensitivity | Raised by a longer wire (smaller k) | Fixed by the instrument |
| Method | Null (zero deflection) | Deflection |
Sensitivity improves when the gradient k is smaller, because a given shift of the jockey then changes the potential by less. A smaller k is obtained by increasing the rheostat resistance, which reduces the driver current. The balance length gets longer, so the relative error Δl/l falls.
Common traps
- If the balance point is not found, the first checks are the driver EMF (too low) and the polarity of connections.
- If the balance length with R across the cell is larger than the open-circuit length, the readings were swapped, since l₂ must be less than l₁.
- If the driver cell runs down during the experiment, k drifts, and the ratio l₁/l₂ becomes unreliable. This is a systematic error.
- Do not slide the jockey along the wire while pressing, since this scrapes the wire and makes it nonuniform. Tap it instead.
- Keep the shunt key closed only briefly while taking the l₂ reading, because current through the test cell heats it and changes its internal resistance.
- If the question gives the wire length and the potential across it, compute k = V/L first, then E = k·l.
Worked example
A 10 m wire has a potential difference of 2.0 V across it. A cell balances at 380 cm. Its EMF is
k = 2.0 V / 10 m = 0.20 V/m, so E = 0.20 × 3.80 = 0.76 V.
When a 5.0 Ω resistor is connected across the cell, the balance length changes to 342 cm. Then
r = 5.0 × (380 − 342)/342 = 5.0 × 38/342 ≈ 0.56 Ω.
Exercise
A potentiometer wire is 10 m long and has a resistance of 20 Ω. It is connected in series with a driver cell of EMF 3.0 V (negligible internal resistance) and a rheostat of 40 Ω. Find the potential gradient along the wire, and the balance length for a cell of EMF 0.60 V.
Show answer
The total resistance is 20 + 40 = 60 Ω, so the current is 3.0/60 = 0.050 A. The potential drop across the wire is 0.050 × 20 = 1.0 V over 10 m, so k = 0.10 V/m. The balance length is l = E/k = 0.60/0.10 = 6.0 m.
Exercise
A cell has balance length 600 cm on open circuit. With a 9.0 Ω resistor across it, the balance length is 540 cm. Find its internal resistance, and state which term dominates the relative error if each length has an error of 0.1 cm.
Show answer
r = R(l₁ − l₂)/l₂ = 9.0 × 60/540 = 1.0 Ω. The difference l₁ − l₂ = 60 cm has absolute error 0.2 cm, a relative error of 0.2/60 ≈ 0.33%. The terms Δl₂/l₂ ≈ 0.019% and ΔR/R are smaller, so the difference term dominates.
Exercise
Why does a potentiometer measure the EMF of a cell more accurately than a voltmeter, and why does the balance point fail to appear if the driver cell has an EMF lower than the test cell?
Show answer
At balance no current flows through the test cell, so there is no drop across its internal resistance and the potential difference equals the EMF. A voltmeter draws some current, so it reads below E. If the driver EMF is lower than the test cell EMF, the total potential drop across the whole wire is less than E, so no point on the wire can match E, and the galvanometer always deflects the same way.