Sub topic 14
Resistance from voltmeter and ammeter readings
This chapter assumes you know Ohm's law, series and parallel circuits, and how to propagate errors through quotients (from the earlier chapters). It also assumes you can read a least-squares slope from a graph. Here you will use them together in the most common electrical experiment in JEE.
The principle
For an ohmic conductor, the potential difference V across it is proportional to the current I through it, so R = V/I. The experiment connects a voltmeter and an ammeter around an unknown resistor, a rheostat varies the current, and you record several (I, V) pairs.
The voltmeter is connected in parallel with the resistor. The ammeter is connected in series. Neither meter is ideal, and the two ways of placing them give different systematic errors.
The two connections
In connection A, the voltmeter is across the resistor only. The ammeter reads the resistor current plus the voltmeter current, so the current is overestimated and the computed R is too low:
Rapparent = R·RV / (R + R_V) < R
In connection B, the voltmeter is across the resistor and the ammeter together. The voltmeter reads the resistor drop plus the ammeter drop, so the computed R is too high:
Rapparent = R + RA > R
The fractional errors are approximately −R/RV for connection A and +RA/R for connection B. They are equal in size when R = √(RA·RV). Use A for resistances below this value and B for resistances above it.
Computing the meter-loading error
import math
def apparent_a(R, Rv):
"""Voltmeter directly across the resistor."""
return R * Rv / (R + Rv)
def apparent_b(R, Ra):
"""Voltmeter across resistor and ammeter."""
return R + Ra
Rv, Ra = 1000.0, 0.5
print(f"crossover R = {math.sqrt(Ra * Rv):.1f} ohm")
for R in (10.0, 1000.0):
a = apparent_a(R, Rv)
b = apparent_b(R, Ra)
print(f"R = {R:7.1f} A: {a:7.2f} ({100*(a-R)/R:+.2f}%) B: {b:7.2f} ({100*(b-R)/R:+.2f}%)")For R = 10 Ω, connection A is off by about −0.99% and B by +5.00%, so A is better. For R = 1000 Ω the situation reverses: A is off by −33.33% when R_V = 1000 Ω, which is why the second case uses a stricter limit in practice. Always compare R with both meter resistances before choosing.
The corrected value in connection B is R = V/I − RA. In connection A, it is 1/R = I/V − 1/RV. JEE questions often give RA or RV and ask for exactly this correction.
Error in the result
Because R = V/I is a quotient, the maximum fractional error is the sum of the fractional errors:
ΔR/R = ΔV/V + ΔI/I
Take V = 2.00 ± 0.02 V and I = 0.200 ± 0.002 A. Then R = 10.0 Ω and ΔR/R = 1% + 1% = 2%, so ΔR = 0.2 Ω and R = 10.0 ± 0.2 Ω.
Each fractional error is the meter's least count divided by the reading. A reading near the end of the scale gives a smaller fractional error. A deflection of only a few divisions makes the fractional error large, so adjust the rheostat until the deflections are well up the scale.
Using the graph
A single (V, I) pair gives one value of R and is sensitive to any one bad reading. A V–I graph uses all readings. The slope is R, and the intercept should be zero.
I = [0.1, 0.2, 0.3, 0.4] # current in A
V = [0.52, 0.98, 1.53, 2.01] # potential difference in V
n = len(I)
mean_I = sum(I) / n
mean_V = sum(V) / n
sxx = sum((x - mean_I) ** 2 for x in I)
sxy = sum((x - mean_I) * (y - mean_V) for x, y in zip(I, V))
slope = sxy / sxx
intercept = mean_V - slope * mean_I
print(f"R = {slope:.2f} ohm, intercept = {intercept:.3f} V")This gives R = 5.02 Ω with an intercept of 0.005 V. An intercept this close to zero suggests small zero errors. A large non-zero intercept points to a zero error in a meter, or a contact or wire resistance in series.
Sources of error
- Zero error of the meters. If the voltmeter or ammeter does not read zero with the circuit open, subtract the zero reading from every observation. Check both meters before you start.
- Heating. A large current warms the resistor, and its resistance changes. Keep the current modest and keep the circuit open between readings. Heating makes the V–I graph curve upward in slope-lowering fashion for a metal, so it also affects the graph's linearity.
- Loose connections. Contact resistance adds to R and shows up as a positive intercept in the graph.
- Parallax. Read the pointer with the eye directly above it.
Traps in JEE questions
- Students mix up which connection gives a lower or higher reading. Remember that A reads low (parallel combination) and B reads high (series addition).
- A question may say the voltmeter is "ideal" or the ammeter is "ideal." Then the corresponding loading error is zero and the whole question reduces to ΔV/V + ΔI/I.
- Fractional errors add even though R is a quotient. Do not subtract them.
- When the answer is asked as a percentage, convert ΔR/R to a percentage only at the end.
Exercise
A resistor of about 50 Ω is measured with a voltmeter of resistance 500 Ω and an ammeter of resistance 2 Ω. The voltmeter reads 5.0 V and the ammeter reads 0.110 A in connection A. Find the true resistance R of the resistor, using the correction for connection A.
Show answer
In connection A the ammeter current includes the voltmeter current. The voltmeter current is 5.0/500 = 0.010 A. The resistor current is 0.110 − 0.010 = 0.100 A. So R = 5.0/0.100 = 50 Ω. The uncorrected value 5.0/0.110 = 45.5 Ω is too low, as expected for connection A.
Exercise
In an experiment, V = 3.00 ± 0.03 V and I = 0.500 ± 0.005 A. Give R with its absolute error, taking the maximum error.
Show answer
R = 3.00/0.500 = 6.00 Ω. The fractional errors are 1% and 1%, so ΔR/R = 2%. Then ΔR = 0.02 × 6.00 = 0.12 Ω, so R = 6.00 ± 0.12 Ω.