Sub topic 10
Susceptibility and Permeability of a Material
Prerequisites and scope
This chapter assumes you know the previous chapter's relation B = μ0(H + M). It also assumes you know that H is the magnetic intensity (SI unit A/m) and M is the magnetization, meaning magnetic moment per unit volume (also A/m). You should be comfortable with the field inside a solenoid, B = μ0 n I.
Here we turn that relation into working tools. Susceptibility and permeability tell you how strongly a material responds to an applied field. They also let you predict the field inside the material. Both are common sources of NEET calculation questions.
The linear response model
For many materials, the magnetization is proportional to the magnetic intensity that produces it:
M = χ H
Here χ (Greek chi) is the magnetic susceptibility. It has no unit, because M and H are both measured in A/m.
- χ > 0 means the material magnetizes along H. Paramagnets and ferromagnets behave this way.
- χ < 0 means the material magnetizes against H. Diamagnets behave this way.
- χ = 0 describes vacuum.
The linear relation holds well for dia- and paramagnets. It does not hold for ferromagnets, where M depends on the history of the sample (see the hysteresis chapter).
From B = μ0(H + M) to μ = μ0(1 + χ)
Substitute M = χH into B = μ0(H + M):
B = μ0(H + χH) = μ0(1 + χ) H
Define the relative permeability μr and the permeability μ of the material:
- μr = 1 + χ (dimensionless)
- μ = μ0 μr = μ0(1 + χ) (unit: T m/A, or H/m)
The field inside the material then becomes:
B = μ H = μ0 μr H
Compare this with vacuum, where B = μ0 H. The factor μr tells you how many times stronger the field becomes when the material fills the region, for the same H.
| Quantity | Symbol | Unit | Meaning |
|---|---|---|---|
| Magnetic susceptibility | χ | none | M per unit H |
| Relative permeability | μr | none | B in the material divided by B in vacuum, at the same H |
| Permeability | μ | T m/A | μ0 μr |
| Permeability of free space | μ0 | T m/A | 4π × 10⁻⁷ |
Why H is the right quantity to hold fixed
H depends only on the free current, the current you control with a battery and a coil. For a long solenoid with n turns per unit length carrying current I, H = n I, whatever fills the core. The bound currents inside the material change B and M, but they do not change H.
So the standard workflow for a solenoid with a core is:
- Compute H = n I.
- Find χ or μr from the material.
- Compute B = μ0 μr H and M = χ H.
Worked example: iron-cored solenoid
A long solenoid has 1000 turns per metre and carries 2 A. Its core is filled with a material of relative permeability μr = 500.
- H = n I = 1000 × 2 = 2000 A/m.
- χ = μr − 1 = 499.
- M = χ H = 499 × 2000 = 9.98 × 10⁵ A/m.
- B = μ0 μr H = 4π × 10⁻⁷ × 500 × 2000 ≈ 1.26 T.
Without the core, B = μ0 H ≈ 2.5 × 10⁻³ T. The core multiplies the field by 500.
Notice that M (about 10⁶ A/m) is far larger than H (2000 A/m) here. When χ is large, B ≈ μ0 M, and the applied H contributes almost nothing to the total field.
Typical values by material class
The size and sign of χ is the clearest numerical way to separate material classes. The next chapter compares these classes in full. For now, these ranges are the ones to remember.
| Class | χ | μr | Example |
|---|---|---|---|
| Diamagnetic | small and negative, about −10⁻⁵ | slightly below 1 | Bismuth, copper, water |
| Paramagnetic | small and positive, about 10⁻⁵ to 10⁻³ | slightly above 1 | Aluminium, sodium, oxygen |
| Ferromagnetic | large and positive, often 10² to 10⁵ | much greater than 1 | Iron, nickel, cobalt |
A perfect diamagnet (a superconductor in the Meissner state) has χ = −1. Then μr = 0 and B = 0 inside. This is the lower limit of χ. Any value below −1 would make μr negative, which does not occur for these materials.
Computing with the relations
The code below applies the relations from this chapter. It also checks that the two routes to B (through M and through μr) agree.
import math
MU0 = 4 * math.pi * 1e-7 # T m / A
def intensity_solenoid(n, current):
# H = n I, independent of the core material
return n * current
def magnetization(chi, H):
return chi * H
def field_from_H_and_M(H, M):
return MU0 * (H + M)
def field_from_mu_r(mu_r, H):
return MU0 * mu_r * H
n, current = 1000, 2.0 # turns per metre, amperes
mu_r = 500
chi = mu_r - 1
H = intensity_solenoid(n, current)
M = magnetization(chi, H)
print("H =", H, "A/m")
print("M =", M, "A/m")
print("B via H + M =", field_from_H_and_M(H, M), "T")
print("B via mu_r =", field_from_mu_r(mu_r, H), "T")
print("B in vacuum =", MU0 * H, "T")Both field values print the same number, about 1.2566 T, which is 500 times the vacuum value.
Common errors
- Giving χ a unit. χ and μr are pure numbers. Only μ and μ0 carry the unit T m/A.
- Mixing up μ and μr. The formula μ = 1 + χ is wrong. The correct forms are μr = 1 + χ and μ = μ0(1 + χ).
- Treating H as dependent on the core. For a solenoid, H = n I regardless of material. Only B and M change.
- Using a single χ for a ferromagnet. For iron, μr depends on H and on the sample's past. A quoted value applies only at one point on the magnetization curve.
- Forgetting the sign. A diamagnet has negative χ, so M points opposite to H. This is why μr < 1 for it.
- Mixing M and B units. M and H are in A/m. B is in tesla. Convert with μ0 before adding.
Variants that appear in NEET questions
Finding χ from B and H. If a rod in a field H = 1200 A/m has magnetization M = 2.4 A/m, then χ = M/H = 2.4/1200 = 2 × 10⁻³. This is paramagnetic.
Finding μr from the flux density. If B = 0.6 T when H = 800 A/m, then μ = B/H = 7.5 × 10⁻⁴ T m/A. Then μr = μ/μ0 ≈ 597.
Percentage change in the field. For a paramagnet with χ = 2 × 10⁻⁵, μr = 1.00002. The field rises by only 0.002 percent relative to vacuum. For a diamagnet with χ = −10⁻⁵, the field falls by 0.001 percent.
Link to temperature. For paramagnets, χ = C/T by Curie's law. The chapter on temperature dependence develops this. For now, note that μr = 1 + C/T, so lowering the temperature raises μr toward larger values.
def relative_permeability(chi):
return 1 + chi
def chi_from_M_H(M, H):
return M / H
chi = chi_from_M_H(2.4, 1200)
print(chi, relative_permeability(chi))Key relations to memorize
| Relation | Formula |
|---|---|
| Linear response | M = χ H |
| Relative permeability | μr = 1 + χ |
| Permeability | μ = μ0 μr |
| Field in material | B = μ H = μ0 μr H |
| Field from H and M | B = μ0 (H + M) |
| Solenoid intensity | H = n I |
Exercise
A long solenoid has 500 turns per metre and carries 4 A. Its core has susceptibility χ = 999. Find H, M, μr and B. Use μ0 = 4π × 10⁻⁷ T m/A.
Show answer
H = n I = 500 × 4 = 2000 A/m. M = χ H = 999 × 2000 = 1.998 × 10⁶ A/m. μr = 1 + χ = 1000. B = μ0 μr H = 4π × 10⁻⁷ × 1000 × 2000 ≈ 2.51 T. As a check, μ0(H + M) = 4π × 10⁻⁷ × (2000 + 1 998 000) = 4π × 10⁻⁷ × 2 × 10⁶ ≈ 2.51 T.
Exercise
A magnetic material in a field of H = 5000 A/m has magnetization M = −0.05 A/m. Find χ and μr, and state what kind of material it is.
Show answer
χ = M/H = −0.05/5000 = −1 × 10⁻⁵. μr = 1 + χ = 0.99999. Because χ is small and negative, and μr is slightly less than 1, the material is diamagnetic.
Exercise
Why is it wrong to say that a superconductor in the Meissner state has μr = −1?
Show answer
A perfect diamagnet has χ = −1, not μr = −1. Since μr = 1 + χ, μr = 1 − 1 = 0. The field inside is B = μ0 μr H = 0.