Sub topic 13
Hysteresis loop, retentivity, coercivity and energy loss
This chapter assumes you know the relations B = μ0(H + M), M = χH and μ_r = 1 + χ from the earlier chapters, and that you can tell diamagnetic, paramagnetic and ferromagnetic materials apart. It also assumes you know that a ferromagnet is made of domains, which are small regions where atomic dipoles are already aligned with each other.
Why a ferromagnet has a memory
For a paramagnet or a diamagnet, M depends only on the present value of H. Switch H off and M returns to zero. A ferromagnet behaves differently. Its magnetization depends on the path the material took to get there. If you magnetize an iron bar and then remove the current, the bar stays magnetized. This dependence on history is called hysteresis, from a Greek word meaning "lagging behind". The magnetization lags behind the field that causes it.
Two ideas explain the lag:
- Domain walls, the boundaries between domains, get caught on impurities and crystal defects. Moving them is not perfectly reversible.
- Domains that have rotated into the field direction do not all rotate back when the field is removed.
So the loop is a property of the material and also of its internal structure. This is why a hard-drawn, impure steel and a soft, pure annealed iron have very different loops.
Setting up the experiment
Place a ferromagnetic rod inside a long solenoid. The magnetic intensity H inside the solenoid is H = nI, where n is the number of turns per unit length and I is the current. You control H by changing I. You then measure the magnetic field B inside the rod, or equivalently M, because B = μ0(H + M).
Plot B (or M) on the vertical axis against H on the horizontal axis. Start with an unmagnetized sample, raise the current, reduce it to zero, reverse it, and then bring it back. The curve you trace is the hysteresis loop.
Reading the loop
Follow the stages in order.
- Virgin curve. The sample starts with B = 0 and H = 0. As H rises, B rises along the initial magnetization curve. It is steep at first, because domain walls move easily, and then it flattens.
- Saturation. At high H, nearly every domain points along the field. M reaches its maximum value, the saturation magnetization. Increasing H further adds almost nothing to M. B still creeps up slightly because of the μ0H term.
- Retentivity (remanence). Reduce H to zero. B does not fall back to zero along the same path. The value of B left at H = 0 is the retentivity, also called remanence. It measures how strongly the material stays magnetized after the field is removed.
- Coercivity. To demagnetize the sample you must reverse the current. The reverse value of H needed to bring B back to zero is the coercivity, also called the coercive field. It measures how strongly the material resists demagnetization.
- Reverse saturation. Keep increasing the reverse field. The sample saturates in the opposite direction.
- Closing the loop. Reduce the reverse field to zero, then raise the forward field. The curve passes through the negative retentivity and the positive coercivity point and returns to saturation. Every further cycle follows this closed loop.
The loop is symmetric about the origin. The virgin curve is traced only once, on the first magnetization.
| Quantity | Where on the loop | Meaning |
|---|---|---|
| Saturation | Top right and bottom left tips | All domains aligned, M at its maximum |
| Retentivity | B-axis intercept (H = 0) | Magnetism left after removing the field |
| Coercivity | H-axis intercept (B = 0) | Reverse field needed to erase it |
| Loop area | Enclosed region | Energy lost per unit volume per cycle |
Retentivity and coercivity are different things
Students often mix these up. A material can have high retentivity and low coercivity, or the reverse.
- Retentivity answers: "How much magnetism is left when H = 0?"
- Coercivity answers: "How much reverse H is needed to remove it?"
Because the coercivity is a field strength in H, its SI unit is A m⁻¹. Retentivity is a value of B (or M), so its unit is tesla (or A m⁻¹ for M).
Energy loss per cycle
Taking a ferromagnet around one full loop costs energy. The work done per unit volume in changing the magnetization is ∮H dB (more precisely, the part that does not return). Over one complete cycle, this equals the area enclosed by the B-H loop. That energy appears as heat in the material.
> Energy dissipated per unit volume per cycle = area of the B-H loop.
The units confirm this. H is in A m⁻¹ and B is in T, so the area has units A m⁻¹ × T. Since 1 T = 1 N A⁻¹ m⁻¹, the product is N m⁻² = J m⁻³. That is energy per unit volume.
For the total heat produced, multiply by the volume of the core and by the number of cycles. A transformer core on a 50 Hz supply goes through 50 cycles every second, so the power lost is
P = (loop area) × (volume) × f
where f is the frequency.
A worked example
A transformer core has a volume of 0.02 m³. Its B-H loop has an area of 400 J m⁻³ per cycle. The supply frequency is 50 Hz. Find the power lost to hysteresis.
The code below computes it.
def hysteresis_power(loop_area_j_per_m3, volume_m3, frequency_hz):
energy_per_cycle = loop_area_j_per_m3 * volume_m3 # joules per cycle
return energy_per_cycle * frequency_hz # watts
loop_area = 400.0 # J m^-3 per cycle
volume = 0.02 # m^3
f = 50.0 # Hz
print(hysteresis_power(loop_area, volume, f)) # 400.0 WThe energy per cycle is 400 × 0.02 = 8 J. At 50 cycles per second the power is 8 × 50 = 400 W. This is heat the transformer must dissipate.
A related loss is eddy-current loss. Changing flux induces circulating currents in the core. This is a separate mechanism from hysteresis loss, and laminated cores reduce it. Do not confuse the two. Hysteresis loss comes from the loop area. Eddy-current loss comes from induced currents.
Soft and hard magnetic materials
The shape of the loop tells you what a material is good for.
| Property | Soft ferromagnet (for example soft iron) | Hard ferromagnet (for example steel, alnico) |
|---|---|---|
| Loop shape | Narrow and tall | Wide and fat |
| Coercivity | Low | High |
| Retentivity | High (but easily lost) | High |
| Loop area | Small | Large |
| Energy loss per cycle | Small | Large |
| Magnetizes and demagnetizes | Easily | With difficulty |
| Typical use | Electromagnets, transformer cores, motors | Permanent magnets |
A soft material has a narrow loop, so little energy is lost each cycle. It is also easy to magnetize and demagnetize. It suits any device where the field keeps reversing or where you need to switch the magnetism off.
A hard material has a wide loop. The high coercivity means the magnetization is hard to erase, which is what a permanent magnet needs.
Demagnetizing a magnet
The loop also explains how to demagnetize a sample. You can:
- Apply a reverse field equal to the coercivity, which brings B to zero.
- Place the sample in a solenoid carrying alternating current and slowly reduce the current to zero. The sample traces smaller and smaller loops that shrink toward the origin, so it ends with no net magnetization.
- Heat it above the Curie temperature, where the ferromagnetic order disappears.
The second method is the standard one, because a single reverse pulse can leave the sample slightly magnetized in the wrong direction.
Common errors
- Reading loop area as a field. The area is an energy density in J m⁻³, not a magnetic quantity such as B or H.
- Swapping the axes. Retentivity is on the B axis. Coercivity is on the H axis.
- Thinking retentivity means "strong magnet". A material with high retentivity but also low coercivity loses its magnetism easily and makes a poor permanent magnet.
- Assuming the loop is retraced. The path out and the path back differ. That difference is the hysteresis.
- Forgetting that B includes μ0H. Past saturation, B still rises slowly, even though M is constant.
Exercise
A ferromagnetic rod is placed in a solenoid. The current is raised until the rod saturates, then reduced to zero, and then reversed. At H = 0 the rod has B = 1.2 T. B falls to zero when the reverse H is 80 A m⁻¹. State the retentivity and the coercivity. Which kind of material is it likely to be: soft or hard, given that a field of only 80 A m⁻¹ erases it?
Show answer
The retentivity is the value of B at H = 0, so it is 1.2 T. The coercivity is the reverse H at which B = 0, so it is 80 A m⁻¹. A coercivity this small means the loop is narrow, so the material is soft, like soft iron. It is suitable for an electromagnet or a transformer core and unsuitable for a permanent magnet.
Exercise
A core of volume 0.05 m³ is run on a 60 Hz supply. Its B-H loop encloses 250 J m⁻³ per cycle. Find the power lost to hysteresis.
Show answer
Energy per cycle = 250 × 0.05 = 12.5 J. Power = 12.5 × 60 = 750 W.
Exercise
Why is the area of the B-H loop equal to an energy per unit volume? Check the units.
Show answer
H has units A m⁻¹ and B has units T, which is N A⁻¹ m⁻¹. Their product is N m⁻², which equals J m⁻³. This is energy per unit volume, and it is the energy dissipated as heat in one cycle.