Sub topic 13
Recording the Evidence and Deciding What Happens Next
This chapter assumes you know basic Lean Six Sigma terms, including DMAIC, defect, process output \(Y\), input \(X\), and root cause. You should also be comfortable with means, variation, histograms, and run charts.
Verification ends with a decision based on evidence. The decision is not simply “the p-value was below 0.05.” You must connect the suspected cause to the predicted process behavior, check data quality, consider alternative explanations, and state what happens next.
Build an evidence record
Record the verification work while it is happening. A useful evidence record contains:
- The original root-cause statement.
- The measurable prediction.
- The data source, time period, and sampling method.
- The operational definitions for the defect and suspected cause.
- Measurement-system checks and data-cleaning decisions.
- Graphs showing the relationship.
- The statistical test, assumptions, sample size, effect size, and p-value.
- Alternative explanations that were considered.
- The final decision and its owner.
Use a specific cause statement. “Operators make mistakes” is too broad. “The defect rate is higher on shift B because the final inspection checklist is not available at that station” can be tested.
The prediction should include direction and size when possible. For example, the prediction might be that shift B has a defect rate at least 5 percentage points higher than shift A. A practical threshold prevents a statistically detectable but unimportant difference from being treated as a critical cause.
Interpret the result against the claim
Use both statistical and practical evidence.
| Evidence | Question | Possible conclusion |
|---|---|---|
| Difference or relationship | Does the suspected cause relate to the output? | The observed pattern supports or challenges the hypothesis. |
| Effect size | Is the difference large enough to matter? | The cause may be practically important or negligible. |
| P-value and confidence interval | How compatible are the data with no effect? | The evidence is stronger or weaker than the chosen standard. |
| Data and measurement quality | Can the result be trusted? | The study is usable, limited, or invalid. |
| Alternative explanations | Could another factor explain the pattern? | Further analysis or an experiment is needed. |
A small p-value does not prove that the cause produced the effect. A large p-value does not prove that the cause has no effect. It may indicate insufficient data, excessive variation, or a poor measurement method.
State the conclusion with appropriate strength:
- Accept provisionally: The data support the cause, the effect is meaningful, and important alternatives have been addressed.
- Reject: The prediction was not observed, or the suspected cause has little practical effect.
- Revise: The evidence points to a different level, condition, or mechanism.
- Collect more data: The study was inconclusive because of weak measurement, too few observations, or an unclear prediction.
- Run a confirmatory experiment: The relationship is promising, but confounding prevents a causal conclusion.
Make the decision traceable
A decision should be reproducible by someone who was not involved in the analysis. Save the original data, analysis code or calculation steps, chart versions, and decision date. Record exclusions instead of silently removing unusual observations.
When the cause is accepted, define the next action in Improve. Specify the change, process owner, expected benefit, implementation date, and verification metric. When the cause is rejected, return to the prioritized cause list rather than forcing an improvement around a weak explanation.
The following flow shows how evidence leads to an action.
Example decision statement
A clear conclusion might read:
> The hypothesis predicted that shift B would have a defect rate at least 5 percentage points above shift A. Across 400 units collected using the same inspection method, shift B was 11.5 percentage points higher. The difference was statistically significant, and the measurement check found no important shift effect. Because product mix differed slightly by shift, the cause is accepted provisionally. A controlled trial of the checklist will be run before the improvement is made permanent.
This statement identifies the prediction, evidence, limitation, and next step.
Exercise
The p-value is 0.03, but the observed defect-rate difference is only 0.2 percentage points and the measurement system was not checked. Should the cause be accepted?
Show answer
No. The statistical result alone is insufficient. The effect may be practically unimportant, and the unverified measurement system limits trust in the result. Check measurement quality and compare the effect with the project’s practical threshold.