Sub topic 8
Storage and RAID Failures
This chapter covers how to tell a failing drive from a corrupted file system, how to read the symptoms of each drive type, and how to respond when a RAID array degrades. It assumes you know the CompTIA troubleshooting steps and the POST sequence from earlier chapters. You should also know the difference between an HDD, an SSD, and an NVMe drive, and be comfortable with the Windows command line.
Start with the symptom
Storage faults show up in a few recurring ways. The first job is to decide whether the problem is physical (the drive or its cable), logical (the file system or the data on it), or configuration (BIOS/UEFI settings, boot order, or the RAID controller).
| Symptom | Likely cause | First check |
|---|---|---|
| Clicking, grinding, or repeated spin-up sounds | Failing HDD (head or motor fault) | Back up now, then check SMART |
| "No boot device found" or "Operating system not found" | Drive not detected, wrong boot order, damaged boot sector | Check that the drive appears in UEFI/BIOS |
| Drive missing from BIOS | Loose or bad SATA/power cable, dead drive, disabled port | Reseat cables, try another port |
| Very slow file access, long freezes | Bad sectors, a nearly full drive, or a fragmented HDD | SMART status, free space |
| Files vanish or will not open | File system corruption | `chkdsk` |
| Intermittent disappearance of an SSD | Failing controller, loose M.2 seating, or power issues | Reseat the drive, update firmware |
| Blue screen with a disk-related stop code | Bad sectors, corrupt file system, or failing drive | Event Viewer, then SMART |
| RAID reports "degraded" | One member disk has failed or dropped out | Identify the failed disk |
Physical failure versus logical failure
Many wrong exam answers come from confusing these two. A physical failure means the hardware is failing. A logical failure means the hardware works but the data structures on it are damaged.
- Physical signs: noises from an HDD, the drive disappearing from firmware, a rising count of reallocated sectors in SMART, and a SMART overall status of "failing".
- Logical signs: the drive appears and spins normally, but files are missing, folders are unreadable, or Windows asks to scan the drive after an unexpected shutdown.
SMART (Self-Monitoring, Analysis and Reporting Technology) is a monitoring system built into drives. The drive tracks its own error counts and reports a pass or fail status. A passing result does not guarantee health, because some drives fail with no warning. A failing result means you should copy the data off immediately.
Checking drive health
On Windows, PowerShell can report each physical disk's health:
Get-PhysicalDisk | Select-Object FriendlyName, MediaType, HealthStatus, OperationalStatusHealthStatus shows Healthy, Warning, or Unhealthy. A Warning or Unhealthy value is a reason to back up first and troubleshoot second.
On Linux, smartctl from the smartmontools package asks the drive for its overall result:
sudo smartctl -H /dev/sdaA healthy drive returns a line such as SMART overall-health self-assessment test result: PASSED. Use sudo smartctl -a /dev/sda for the full attribute list, including reallocated and pending sector counts.
Checking the file system
chkdsk examines a volume's file system. The online scan reads the volume while Windows keeps running:
chkdsk C: /scanIf the scan finds errors, chkdsk C: /f fixes file system errors and usually needs a restart for the system volume. The /r switch also locates bad sectors and recovers readable data, so it takes much longer. This distinction is useful on the exam: /f repairs the file system, while /r also scans the surface for bad sectors.
A clean chkdsk result with a drive that still misbehaves points back toward hardware. Repeated file system errors on the same drive point to a failing drive, not a one-time corruption.
HDD, SSD, and NVMe differences
The drive type changes both the symptoms and the safe response.
| Feature | HDD | SATA SSD | NVMe SSD |
|---|---|---|---|
| Moving parts | Yes (platters, heads) | No | No |
| Typical failure signs | Clicking, grinding, slow reads, bad sectors | Sudden disappearance, read-only mode, slow writes | Sudden disappearance, overheating throttling |
| Defragmentation | Helpful | Not needed | Not needed |
| Connection | SATA data + SATA power | SATA data + SATA power | M.2 slot (PCIe) |
Key points for each type:
- HDD: Mechanical wear is the main risk. Noise is a strong sign of head or motor trouble. Shock damage from drops is common in laptops.
- SSD: Flash cells wear out after many writes. A worn SSD may switch to read-only mode to protect data. Do not defragment an SSD, because it adds writes and gives no speed benefit.
- NVMe: These drives run hot. Sustained transfers can trigger thermal throttling, which looks like a sudden drop in speed. A heatsink or better airflow fixes it. A drive that vanishes may simply be loose in its M.2 slot.
A drive that vanishes from UEFI/BIOS is a good example of working through causes from cheapest to most expensive:
- Reseat the data and power cables, or reseat the M.2 card.
- Try a different SATA port and a different cable.
- Confirm the port is enabled in UEFI/BIOS settings.
- Test the drive in another computer or through a USB adapter.
- If it still does not appear, replace the drive.
Boot errors tied to storage
Several boot messages point at storage. Know what each one usually means.
- "No boot device found" / "Boot device not found": The firmware sees no bootable drive. Check that the drive is detected, then check boot order and the boot mode (UEFI versus legacy BIOS).
- "Operating system not found" / "Missing operating system": The drive is detected but has no usable boot record or system files. This is often a damaged boot sector or a changed boot mode.
- "Inaccessible boot device" (blue screen): Windows cannot read its boot volume. Causes include a changed storage controller mode (such as AHCI versus RAID) or a corrupt volume.
- Boot loops after a failed update: This is a software problem. Startup repair or the recovery environment is the next step, not a new drive.
Understanding RAID
RAID (Redundant Array of Independent Disks) combines several physical drives into one logical unit. Some levels improve speed, some add fault tolerance, and some do both. RAID is not a backup. It protects against a drive failure, not against deletion, malware, or controller failure.
| Level | Minimum drives | How it works | Fault tolerance |
|---|---|---|---|
| RAID 0 | 2 | Stripes data across drives | None. One failure loses everything |
| RAID 1 | 2 | Mirrors data on both drives | One drive can fail |
| RAID 5 | 3 | Stripes data with distributed parity | One drive can fail |
| RAID 6 | 4 | Stripes with two parity blocks | Two drives can fail |
| RAID 10 | 4 | Mirrored pairs that are striped | One drive per mirrored pair |
Parity is extra calculated data that lets the array rebuild the contents of a lost drive from the remaining drives.
Degraded arrays and rebuilds
An array is degraded when it has lost a member drive but still works. Performance drops, and a second failure (in RAID 1 or RAID 5) causes total data loss. The response is:
- Identify which drive failed, using the RAID controller utility or the status lights on the drive bays.
- Back up critical data if the array is still readable.
- Replace the failed drive with one of equal or larger capacity.
- Start the rebuild, which regenerates the data onto the new drive. Leave the system on until it finishes.
A rebuild puts heavy load on the surviving drives, and drives bought together often wear at the same rate. This is why a second drive sometimes fails during a rebuild.
The diagram shows the usual path for a degraded array.
Other RAID problems
- Array not detected or "failed" status: More drives were lost than the level allows, or the controller lost its configuration. Do not initialize the disks, since that erases the data.
- Wrong or missing array after a motherboard swap or BIOS reset: The controller mode may have changed. Restore the original mode before anything else.
- Mixed drive sizes: The array usually treats every drive as the size of the smallest one, which wastes space.
- Hot-swap: Server bays that support hot-swap let you replace a failed drive without powering off. Ordinary desktop SATA ports usually do not, so shut the system down first.
Other causes of storage trouble
Not every storage symptom is the drive's fault. Before replacing hardware, rule out these items:
- Power: A weak power supply or a bad SATA power connector can cause drives to drop out or click as they spin up.
- Cables: A damaged SATA data cable causes intermittent errors and slow transfers.
- Heat: Poor airflow slows NVMe drives and shortens HDD life.
- Full drive: A nearly full system drive slows Windows and blocks updates. Free space or add capacity.
- Driver or controller mode: A changed AHCI or RAID mode can cause "inaccessible boot device".
Applying the methodology
Here is a scenario worked through the CompTIA steps.
A user reports that a workstation is slow and files sometimes will not open. The system has one HDD.
- Identify the problem: Ask when it began, whether anything changed, and whether there are noises. Back up data first.
- Establish a theory: Either the file system is corrupt or the drive is failing.
- Test the theory:
Get-PhysicalDiskshowsWarning.smartctlshows reallocated sectors. The theory of a failing drive is confirmed. If the health had beenHealthy, you would runchkdsk C: /scanto test the file system theory. - Plan and implement: Clone or copy the data, replace the drive, and restore the system.
- Verify: Confirm the new drive reports
Healthyand the files open. - Document: Record the symptoms, the SMART findings, and the replacement.
Exercise
A technician finds that a file server using RAID 5 shows a "degraded" status. All data is still accessible. What should the technician do first, and why should the array not be left in this state?
Show answer
Identify the failed drive and make sure critical data is backed up, then replace the drive with one of equal or larger capacity and let the array rebuild. The array is still running without protection. A second drive failure before the rebuild finishes would cause total data loss.
Exercise
A user's PC shows "Operating system not found" after the user changed settings in UEFI. SMART reports the drive as healthy. What should you check first?
Show answer
Check the boot order and boot mode (UEFI versus legacy) and the storage controller mode (AHCI versus RAID) in UEFI/BIOS. A healthy drive combined with a recent settings change points to configuration, not a failed drive.
Exercise
What is the difference between chkdsk /f and chkdsk /r, and why should you avoid /r on a drive that is clicking?
Show answer
/f fixes file system errors. /r also scans for bad sectors and recovers readable data, which takes much longer and reads the whole drive. On a clicking, physically failing drive, that load can finish it off, so copy the data off first.