Sub topic 2
Safety Practices and Diagnostic Tools
This chapter covers the safety habits and bench tools that CompTIA A+ expects you to use before and during hardware troubleshooting. It assumes you know the main internal parts of a desktop PC, the difference between a laptop and a desktop, and how to open a Windows command prompt or PowerShell window. The previous chapter gave you the troubleshooting steps. This chapter covers the equipment and precautions that go with them.
Why safety comes first
Hardware troubleshooting puts you close to two hazards. The first is electrostatic discharge (ESD), a sudden flow of static electricity between two objects at different charges. The second is mains electricity, the power from the wall outlet, along with stored energy inside certain parts.
ESD is the quiet hazard. You can feel a static shock only above about 3,000 volts. Many chips can be damaged by 100 volts or less. A part can therefore be harmed without any sign, and it may fail weeks later. This is called latent damage. A part that fails at once is called catastrophic damage.
Electrical shock is the dangerous hazard. It matters most inside a power supply unit (PSU), a CRT monitor, a laser printer, or any device with large capacitors. A capacitor is a part that stores charge and can hold it after the power is off.
ESD protection
The goal of ESD protection is to keep you, the part, and the work surface at the same electrical potential. If nothing differs in charge, nothing discharges.
| Tool | What it does | Notes for the exam |
|---|---|---|
| ESD wrist strap | Connects your skin to ground through a resistor | Clip the other end to bare metal on the case, or to a grounded point |
| ESD mat | Gives a grounded work surface | Connect it to ground and, ideally, connect your strap to it |
| Antistatic bag | Shields a part during storage and transport | Keep parts in it until you install them |
| ESD-safe tools and gloves | Avoid generating charge | Gloves are secondary to a strap |
| Humidity control | Dry air makes static build up faster | Aim for roughly 40 to 60 percent relative humidity |
Follow these practices:
- Touch bare metal on the case before you handle components, if you have no strap.
- Hold cards and memory by their edges. Do not touch the contacts or chips.
- Do not wear a wrist strap when working inside a PSU or a CRT monitor. The strap would give current a path through your body.
- Do not work on carpet, and avoid clothing that builds static, such as wool.
- Place a removed part on an antistatic mat or in an antistatic bag, never on the plain case or a regular table.
A related point is that the PSU should stay plugged into the wall but switched off when you work on a desktop, if you rely on the case as your ground. Many technicians unplug the PC instead and press the power button once to drain residual power. A grounded cord connects the case to the building ground, but the safer default for exam answers is to disconnect power before you open the case. If an exam scenario describes installing or removing parts, the answer includes disconnecting power first.
Electrical and general safety
Use these rules whenever you work on equipment:
- Power off and unplug the device before you open it. For a laptop, remove the battery as well, where the battery is removable. If the battery is internal, disconnect its connector from the motherboard first.
- Do not open a PSU. Replace the whole unit. It contains capacitors that can hold a dangerous charge even when unplugged.
- Do not wear jewelry that can touch live parts or catch on components.
- Lift heavy items with your legs, not your back. Ask for help with a rack-mounted unit or a large UPS.
- Keep cables out of walkways to avoid trips. Use cable management where possible.
- Know where the fire extinguisher is. For electrical fires, use a Class C extinguisher, or a multi-class ABC unit. Never use water.
- Wear safety goggles when you use compressed air or work with parts that can shatter or throw debris.
- Use an air filter mask when you clean dust or toner. Toner is fine powder that you should not breathe.
Handling hazardous materials
Some components need special disposal. The exam links these to local regulations and to the Safety Data Sheet (SDS), a document that describes a material's hazards, handling, and disposal. Batteries, toner cartridges, and CRT monitors should not go in ordinary trash. A damaged lithium-ion battery that is swollen should be removed from service and recycled. Do not puncture it.
Documentation of a hazard
Report any unsafe condition, such as a frayed cord or overloaded power strip, according to company policy. Document what you found and what you changed. This also supports step 6 of the troubleshooting method, which is to document findings, actions, and outcomes.
Diagnostic tools
Safety covers how to work. Diagnostic tools cover how to find the fault. Match each tool to the symptom.
Multimeter
A multimeter is a handheld meter that measures voltage, resistance, and sometimes current. Use it on a PSU connector, a battery, an AC outlet, or a cable.
- Voltage mode checks that a PSU rail outputs the right value. Typical rails are +3.3 V, +5 V, and +12 V. Most ATX power supplies are acceptable within about 5 percent.
- Continuity mode checks that a cable or fuse is unbroken. A beep or near-zero reading means a complete path. No beep means a break.
- Resistance mode (ohms) checks parts such as a fan or a cable run for an open circuit.
Set the meter to the correct mode and range before you probe. Reading AC voltage with the meter set to DC gives a wrong reading.
PSU tester
A PSU tester plugs into the connectors of a PSU and shows if the main rails are present and in range. It is faster than a multimeter for a pass or fail result, and it works with the PSU unplugged from the motherboard. Its limit is that it tests with little or no load. A PSU can pass the tester and still fail under real load. A multimeter test under load, or swapping in a known good PSU, gives a better result.
Loopback plug
A loopback plug is a connector that sends a device's transmit signal straight back to its receive pins. It tests a port or a network interface without an external device. Common types are a network loopback adapter, a serial loopback, and an audio loopback. If the port passes the test with the plug, the fault is likely the cable or the device on the other end.
POST card
A POST card (or POST diagnostic card) is an expansion card or USB device that displays a code for each stage of the power-on self-test. Use it when the system gives no beeps and no video. The next chapter covers how to read these codes.
Cable tester and toner probe
A cable tester checks a network cable for opens, shorts, and miswiring. A toner probe (tone generator and probe) helps trace a cable through walls or bundles. These are more common in network work, but A+ may ask you to choose between them.
Other bench tools
- Compressed air removes dust from fans, heat sinks, and vents. Hold a fan blade still so it does not overspin.
- Isopropyl alcohol (90 percent or higher) and lint-free cloths clean contacts and old thermal paste.
- Thermal paste is a compound that fills tiny gaps between a CPU and its cooler. Replace it when you remove a cooler.
- Screwdrivers, a parts tray, and a labeled bag set keep screws organized. Photograph cable positions before you unplug anything.
- Spare known-good parts let you swap a suspect part to isolate the fault.
The following diagram shows how to choose a tool from a symptom.
Software diagnostic tools
Hardware tools find physical faults. Software tools show health data that the operating system or firmware reports. The following commands appear in the exam objectives or in daily support work.
Battery and power
The first command writes an HTML report to your user folder. It lists the design capacity (what the battery held when new) and the full-charge capacity (what it holds now). A large gap shows wear.
powercfg /batteryreport /output "$env:USERPROFILE\battery-report.html"The second command reads the live battery state and charge percentage. It helps you decide whether the laptop is charging, discharging, or not detecting the battery.
Get-CimInstance Win32_Battery | Select-Object Name, BatteryStatus, EstimatedChargeRemainingIf the command returns nothing, Windows does not see a battery. That points to a missing, dead, or disconnected battery, or to a failed connector.
Memory
The Windows Memory Diagnostic tool tests RAM. When you start it, it offers to restart the computer and run the test.
mdsched.exeUse it for random crashes, blue screens, or memory errors. A pass does not prove the RAM is good, because some faults appear only under heat or load. Many technicians run a longer third-party test as well.
Storage
Two Windows tools help you separate file system faults from drive faults. The first command lists each physical disk with a health status.
Get-PhysicalDisk | Select-Object FriendlyName, MediaType, HealthStatus, OperationalStatusA HealthStatus of Warning or Unhealthy means you should back up data at once. The second command scans the C: volume for file system errors without taking it offline.
chkdsk C: /scanIf chkdsk finds and fixes file system errors but the disk reports healthy, the problem was likely corruption, for example from a sudden power loss. If the disk is unhealthy, replace it.
On Linux, smartctl from the smartmontools package asks a drive for its SMART (Self-Monitoring, Analysis and Reporting Technology) result.
sudo smartctl -H /dev/sdaA result of PASSED is good, but it is not a guarantee. A drive can fail soon after a pass. Treat a FAILED result as urgent.
Common mistakes
- Testing a PSU with a tester only and ruling it out. A PSU can pass without load and fail with load.
- Using a wrist strap inside a PSU or CRT.
- Opening a PSU to "fix" it instead of replacing it.
- Measuring a rail with the meter in the wrong mode.
- Removing a part from the bag and setting it on the bare case.
- Skipping the backup before disk diagnostics.
Putting it together
Suppose a desktop will not power on. Follow this order:
- Confirm the outlet or power strip works. Move the cable to another outlet.
- Power off and unplug the PC, then put on your ESD strap.
- Check that the internal power cables are seated.
- Use a PSU tester to check the rails. If it passes, test under load with a multimeter or swap in a known-good PSU.
- Record what you did and what the result was.
Exercise
A technician wants to know whether a desktop PSU's +12 V rail is within tolerance while the PC is running. Which tool fits best, and should the technician wear an ESD wrist strap while opening the PSU itself to inspect it?
Show answer
A multimeter in DC voltage mode is the best fit because it reads the real rail voltage under load, while a PSU tester checks with little or no load. The technician should not open the PSU, and should not wear a strap if they ever work near high-voltage components, because the PSU holds capacitors that can keep a dangerous charge. The correct action is to replace the PSU if the rail is out of tolerance.
Exercise
A laptop is plugged in but reports that it is not charging. Which Windows command shows how much capacity the battery has lost over time compared with its original design?
Show answer
powercfg /batteryreport produces an HTML report that lists design capacity and full-charge capacity. A big gap between the two means the battery is worn.
Exercise
You run chkdsk C: /scan. It reports file system errors, but Get-PhysicalDisk shows HealthStatus as Healthy. What is the most likely cause, and what should you do before further repairs?
Show answer
The most likely cause is file system corruption rather than a failing drive, for example from an unexpected power loss. Back up the data first, then let chkdsk repair the errors and watch whether the problem returns.