Sub topic 9
Short-circuit current and Rth = Voc/Isc
This chapter assumes you can find an open-circuit voltage with a voltage divider or node analysis, and that you can reduce series and parallel resistors. It also assumes you know the Thévenin and Norton forms from the earlier chapters.
The idea
A Thévenin equivalent is a source Vth in series with Rth. A Norton equivalent is a current source IN in parallel with Rth. Both describe the same two-terminal network, so they must agree at the terminals a-b.
Two measurements at those terminals are enough to find everything:
- Open-circuit voltage, Voc: the voltage at a-b with nothing connected. In this case Voc equals Vth.
- Short-circuit current, Isc: the current through a wire placed across a-b. In this case Isc equals IN.
With the terminals open, no current flows through Rth, so there is no drop across it and Voc = Vth. With the terminals shorted, only Rth limits the current, so Isc = Vth / Rth. Rearranging gives the key relation:
This is valid whenever Isc is not zero and the network is linear.
Worked example
Use the circuit from the earlier chapters: a 12 V source, R1 = 4 ohm in series, and R2 = 6 ohm across terminals a-b.
- Open circuit: the voltage divider gives Voc = 12 × 6 / (4 + 6) = 7.2 V.
- Short circuit: a wire across a-b bypasses R2, so Isc = 12 / 4 = 3 A.
- Resistance: Rth = 7.2 / 3 = 2.4 ohm.
This matches the value found by turning the source off, which leaves R1 in parallel with R2: 4 × 6 / 10 = 2.4 ohm. The code below repeats the calculation.
vs = 12.0 # source voltage in volts
r1 = 4.0 # series resistor in ohms
r2 = 6.0 # resistor across terminals a-b in ohms
v_oc = vs * r2 / (r1 + r2) # open-circuit voltage at a-b
i_sc = vs / r1 # short at a-b removes R2 from the path
r_th = v_oc / i_sc # Rth = Voc / Isc
print(f"Voc = {v_oc:.2f} V, Isc = {i_sc:.2f} A, Rth = {r_th:.2f} ohm")
# Voc = 7.20 V, Isc = 3.00 A, Rth = 2.40 ohmHow the methods connect
When to use this method
Use Voc / Isc when the network contains dependent sources, or when you cannot simply turn sources off. With a dependent source, the "source off" shortcut does not work, because the dependent source must stay active. Finding Voc and Isc as two separate analyses avoids that problem.
Common errors
- Shorting a network with no internal source. If every independent source is off, both Voc and Isc are zero and the ratio is 0/0. Use another method, such as the test-source method.
- Forgetting to remove the load. Compute Voc with the load removed, and compute Isc with the load replaced by the short, not in parallel with it.
- Mixing sign conventions. Keep Voc and Isc oriented consistently, so that Isc flows out of the positive terminal through the short. A negative Rth from sign errors is a warning sign. (Negative Rth can be real with dependent sources, but check your signs first.)
- Shorting a real source. On a bench, a short can damage a battery, supply or meter. Calculate Isc on paper instead.
Exercise
A network has an open-circuit voltage of 15 V at terminals a-b. A wire placed across a-b carries 5 mA. Find Rth and write the Norton equivalent.
Show answer
Rth = Voc / Isc = 15 V / 0.005 A = 3000 ohm = 3 kohm. The Norton equivalent is a 5 mA current source in parallel with 3 kohm, since IN = Isc.
Exercise
For the 12 V, 4 ohm, 6 ohm circuit, a 2.4 ohm load is connected across a-b. Using the Norton equivalent (IN = 3 A, Rth = 2.4 ohm), find the load current.
Show answer
The current divider splits IN equally between two equal resistors, so the load current is 3 × 2.4 / (2.4 + 2.4) = 1.5 A. This matches the Thévenin result 7.2 / (2.4 + 2.4) = 1.5 A.