Sub topic 16
Measuring Vth and Rth on real circuits
This chapter assumes you know how to find Vth and Rth by calculation, and that Rth = Voc/Isc. Here you will find them with a multimeter, a known resistor and, when it is safe, a short circuit.
What you measure
Every method works at the two terminals of the network, with the load removed.
- Vth is the open-circuit voltage Voc at those terminals.
- Rth is the resistance the network presents. You cannot turn off the sources and read it with an ohmmeter unless you can safely remove them. You can usually find it from two voltage readings instead.
Step 1: Measure Voc
Set the meter to voltage and connect it across the open terminals. The reading is Vth.
A meter has its own input resistance, often 10 MΩ. It forms a voltage divider with Rth, so the reading is low when Rth is large. The following code shows the size of the error for a 1 MΩ source.
v_th = 5.0 # true open-circuit voltage in volts
r_th = 1e6 # source resistance in ohms
r_meter = 10e6 # meter input resistance in ohms
v_read = v_th * r_meter / (r_th + r_meter)
print(f"Meter reads {v_read:.3f} V instead of {v_th:.3f} V")
# Meter reads 4.545 V instead of 5.000 VThe error is small when the meter resistance is much larger than Rth. For a 2.4 Ω network the error is negligible.
Step 2: Measure Rth with a known load
Connect a resistor RL of known value and measure the voltage VL across it. The load and Rth form a divider, so VL = Voc × RL / (Rth + RL). Solving for Rth gives:
Rth = RL × (Voc / VL − 1)
For the 12 V, 4 Ω, 6 Ω circuit from earlier chapters, Voc = 7.2 V. A 2.4 Ω load reads 3.6 V.
v_oc = 7.2 # open-circuit reading in volts
r_load = 2.4 # known load in ohms
v_load = 3.6 # reading with the load connected in volts
r_th = r_load * (v_oc / v_load - 1)
print(f"Rth = {r_th:.2f} ohm")
# Rth = 2.40 ohmChoose RL close to the expected Rth. If RL is much larger, VL is almost equal to Voc, and the subtraction Voc/VL − 1 amplifies reading errors. If RL is much smaller, VL is tiny and hard to read accurately.
Step 3: Short-circuit current, with care
If you short the terminals through an ammeter, Rth = Voc/Isc. Use this method only when the source can tolerate it.
- A battery or power supply can deliver a very large current and overheat the wires or the meter fuse.
- The ammeter has its own resistance, called burden, which makes Isc read low.
- A real source may be nonlinear at high current, so Isc gives a Rth that does not describe small-load behavior.
Check the result
Connect a third load and compare the measured voltage with the prediction from your equivalent. For the example, a 7.2 Ω load should give VL = 7.2 × 7.2 / 9.6 = 5.4 V. If the reading differs by more than your meter tolerance, the network is probably not linear over that range, or the first readings were affected by meter loading.
Exercise
A network has Voc = 9 V. With an 18 Ω load connected, the load voltage is 6 V. Find Rth and the Norton current IN.
Show answer
Rth = 18 × (9/6 − 1) = 9 Ω. IN = Voc / Rth = 9 / 9 = 1 A.
Exercise
Why is a 10 MΩ meter a poor choice for measuring Voc of a source with Rth = 10 MΩ, and what will it read if the true Voc is 6 V?
Show answer
The meter and Rth form a 1:1 divider, so the meter reads half the true value, 3 V. A meter with a much higher input resistance is needed.