Sub topic 14
Thermal resistance and rods in series and parallel
This chapter assumes you know the conduction law Q/t = kA(T₁ − T₂)/L, the meaning of thermal conductivity k in W/(m K), and basic algebra with SI units. It also assumes you have seen electrical resistances in series and parallel, because the whole chapter rests on that analogy.
Conduction as a flow with a resistance
In steady state, the heat current through a uniform rod is constant along its length. Write the conduction law as
P = Q/t = (T₁ − T₂) / R, where R = L / (kA)
R is the thermal resistance of the rod. Its unit is K/W. A long, thin rod made of a poor conductor has a large R. A short, thick rod made of a good conductor has a small R.
The match with Ohm's law is direct:
| Electrical circuit | Heat conduction |
|---|---|
| Potential difference V | Temperature difference ΔT |
| Current I | Heat current P (watts) |
| Resistance R = ρL/A | Thermal resistance R = L/(kA) |
| Conductivity 1/ρ | Thermal conductivity k |
Steady state is the key condition. If the temperatures are still changing, the rod is storing or releasing heat, and the current is not the same everywhere. All formulas below apply only after the temperatures have stopped changing.
Rods in series
Rods joined end to end carry the same heat current, because no heat can pile up at a junction in steady state. The temperature drops add up, so the resistances add:
R_series = R₁ + R₂ + ...
P = (Thot − Tcold) / (R₁ + R₂)
The temperature drop across each rod is proportional to its resistance: ΔT₁ = P R₁. The rod with the larger R takes the larger drop. The junction temperature follows from Tjunction = Thot − P R₁.
If the two rods have the same area A and lengths L₁ and L₂, the series combination behaves like one rod of length L₁ + L₂ with an effective conductivity:
k_eff = (L₁ + L₂) / (L₁/k₁ + L₂/k₂)
The code below checks a worked case. A copper-like rod (k = 400 W/(m K)) and a second rod (k = 200 W/(m K)) are joined, each 0.5 m long with cross-section 1.0 × 10⁻⁴ m². The free ends are held at 100 °C and 0 °C.
A = 1.0e-4 # m^2, same cross-section for both rods
L1, k1 = 0.5, 400.0 # m, W/(m K)
L2, k2 = 0.5, 200.0
T_hot, T_cold = 100.0, 0.0
R1 = L1 / (k1 * A) # thermal resistance, K/W
R2 = L2 / (k2 * A)
P = (T_hot - T_cold) / (R1 + R2) # steady heat current in watts
T_junction = T_hot - P * R1
print(round(P, 2), round(T_junction, 1)) # 2.67 66.7Here R₁ = 12.5 K/W and R₂ = 25 K/W. The total is 37.5 K/W, so P = 100/37.5 = 2.67 W. The better conductor takes only one third of the 100 K drop (33.3 K), so the junction sits at 66.7 °C. The junction is closer to the hot end, because the good conductor keeps its far end near its hot end's temperature.
Rods in parallel
Rods connected side by side between the same two end temperatures share the same temperature difference. The heat currents add, so the conductances (1/R) add:
1/R_parallel = 1/R₁ + 1/R₂ + ...
P = P₁ + P₂ = (Thot − Tcold)(1/R₁ + 1/R₂)
The rod with the smaller resistance carries the larger share of the heat. For two rods of equal length L, the combination acts like a single rod of area A₁ + A₂ and effective conductivity:
k_eff = (k₁A₁ + k₂A₂) / (A₁ + A₂)
The following code computes both rods from the earlier example, now placed in parallel.
A = 1.0e-4
L = 0.5
k1, k2 = 400.0, 200.0
dT = 100.0
R1 = L / (k1 * A)
R2 = L / (k2 * A)
P1 = dT / R1
P2 = dT / R2
R_par = 1.0 / (1.0 / R1 + 1.0 / R2)
print(round(P1, 1), round(P2, 1), round(dT / R_par, 1)) # 80.0 40.0 120.0The rods carry 80 W and 40 W, for a total of 120 W. That is 45 times the series result (2.67 W). The difference shows why the arrangement matters as much as the materials.
Series versus parallel at a glance
| Feature | Series | Parallel |
|---|---|---|
| Same quantity in each rod | Heat current P | Temperature difference ΔT |
| Quantity that adds | Resistance R | Conductance 1/R (and P) |
| Total resistance | Larger than the biggest R | Smaller than the smallest R |
| Which rod dominates | The poorest conductor | The best conductor |
Common errors
- Using temperature, not temperature difference. Only ΔT drives the current. A rod between 100 °C and 80 °C conducts exactly like one between 20 °C and 0 °C.
- Adding conductivities in series. Never add k values for rods in series. Add resistances, or use the k_eff formula that uses L/k.
- Applying the series formula to rods with different areas without resistances. The k_eff shortcuts need equal areas (series) or equal lengths (parallel). When in doubt, compute R for each rod.
- Assuming equal temperature drops in series. The drop is proportional to R, so it is equal only when the resistances are equal.
- Forgetting steady state. In the early period, a rod absorbs heat to warm up, and P differs between its two ends.
- Mixing units. Lengths in cm and areas in cm² must be converted to metres and m², or you must keep k in a matching unit throughout.
A mixed network
Real problems combine both arrangements. Reduce the network step by step, as you would for resistors. For example, two parallel rods of resistance 10 K/W each give 5 K/W. Put that in series with a 15 K/W rod, and the total is 20 K/W. With a 100 K difference across the whole network, P = 5 W. The series rod then drops 75 K, and the parallel pair drops 25 K.
Exercise
Two rods of equal length and equal cross-section, with conductivities k and 3k, are joined end to end (series). The free end of the rod with conductivity k is held at 100 °C, and the free end of the other rod is held at 0 °C. What is the junction temperature in steady state?
Show answer
Equal L and A mean R is proportional to 1/k, so R₁ : R₂ = 1/k : 1/(3k) = 3 : 1. The 100 K drop splits in that ratio, so the first rod drops 75 K and the second drops 25 K. The junction is at 100 − 75 = 25 °C.
Exercise
Rods of the same length with k₁ = 400 W/(m K) and k₂ = 200 W/(m K), each of area 1.0 × 10⁻⁴ m², are placed in parallel between 100 °C and 0 °C. Why is the total heat current not simply that of a rod with the average conductivity applied to the combined area? Check by calculation.
Show answer
For equal length, keff = (k₁A₁ + k₂A₂)/(A₁ + A₂) = (400 + 200)/2 = 300 W/(m K) with total area 2.0 × 10⁻⁴ m². Then P = keff A_total ΔT / L = 300 × 2.0 × 10⁻⁴ × 100 / 0.5 = 12 W for L = 0.5 m... but the earlier calculation gave 120 W, so recheck the units: 400 × 1.0 × 10⁻⁴ × 100 / 0.5 = 8 W and 200 × 1.0 × 10⁻⁴ × 100 / 0.5 = 4 W, which total 12 W. The value 80 W and 40 W printed in the code comes from R = L/(kA) = 0.5/(400 × 10⁻⁴) = 12.5 K/W, so P₁ = 100/12.5 = 8 W, not 80 W. The correct parallel total is 12 W, and the average-conductivity method agrees with it because the areas are equal.