Sub topic 13
Conduction: Q/t = kA(T₁ − T₂)/L
This chapter assumes you know the difference between heat and temperature, that you can read °C and K scales, and that you know specific heat and latent heat. It covers conduction in a uniform rod, what thermal conductivity means, and the steady-state conditions that the formula needs. The next chapter extends it to rods in series and parallel.
What conduction is
Conduction is heat transfer through a material without any bulk movement of the material. Hotter particles vibrate harder and pass energy to their cooler neighbours through collisions. In metals, free electrons also carry energy, which is why metals are both good electrical and good thermal conductors.
Heat flows from the higher temperature to the lower temperature. It never flows the other way on its own.
The conduction formula
Take a uniform rod of length L and cross-sectional area A. Its ends are held at temperatures T₁ (hot) and T₂ (cold). The rod is insulated along its sides. Once the rod reaches steady state, the heat current is:
Q/t = kA(T₁ − T₂)/L
The symbols are:
- Q/t is the heat current, the heat flowing per second. Its unit is the watt (W). It is sometimes written H or P.
- k is the thermal conductivity of the material, in W m⁻¹ K⁻¹.
- A is the area perpendicular to the flow, in m².
- L is the length along the flow, in m.
- (T₁ − T₂)/L is the temperature gradient, in K m⁻¹.
The rate grows with k, A and the temperature difference. It falls as the rod gets longer. Because only a difference appears, you can use °C or K for the temperatures. Do not convert to K unless another part of the problem needs it.
Typical values of k
| Material | k (W m⁻¹ K⁻¹), approximate |
|---|---|
| Silver | 430 |
| Copper | 400 |
| Aluminium | 240 |
| Steel | 50 |
| Glass | 1 |
| Water | 0.6 |
| Wood | 0.1 |
| Air | 0.025 |
Air is a very poor conductor. That is why wool, foam and double-glazed windows work: they trap air so it cannot circulate. Trapped air conducts little, and because it cannot move, it carries no heat by convection either.
Steady state and what it means
The formula holds only in steady state. At first, part of the heat entering the rod raises the rod's own temperature. This is the transient stage, and the temperature at each point changes with time.
After a while, every point reaches a fixed temperature. The rod then absorbs no more heat. The heat current is the same at every cross-section, and the temperature falls linearly along the length:
T(x) = T₁ − (T₁ − T₂)x/L
If the sides are not insulated, heat leaks out along the rod and the same current does not flow at every section. Problems normally say "lagged" or "insulated" to tell you the formula applies.
Worked example in code
A copper rod of length 0.5 m and area 2 cm² has one end in boiling water (100 °C) and the other in melting ice (0 °C). Find the heat current and the mass of ice melted per minute, and the temperature at the midpoint.
k = 400.0 # W/(m K), copper
A = 2.0e-4 # m^2 (2 cm^2)
L = 0.5 # m
T1, T2 = 100.0, 0.0 # degrees C
L_f = 3.34e5 # J/kg, latent heat of fusion of ice
P = k * A * (T1 - T2) / L # heat current in watts
m_per_min = P * 60 / L_f # kg of ice melted per minute
x = 0.25 # m, midpoint
T_mid = T1 - (T1 - T2) * x / L
print(round(P, 1)) # 16.0
print(round(m_per_min * 1000, 2)) # 2.87 (grams per minute)
print(round(T_mid, 1)) # 50.0The conversion from heat current to ice melted uses Q = mL_f. This links conduction back to latent heat, a pairing NEET often uses.
Scaling the formula
Many NEET questions change the geometry. Use these rules, each with the other quantities fixed:
- Double the length: the rate halves.
- Double the radius: the area becomes four times larger, so the rate is multiplied by 4.
- Double the temperature difference: the rate doubles.
- Replace copper with steel: the rate falls by the ratio of the k values, here 400/50 = 8.
Common errors
- Using the wrong length. L is the distance along the flow, not the width of the object. For a wall, L is its thickness and A is its face area.
- Using the wrong area. A is the cross-section perpendicular to the flow. For a hollow cylinder wall with radial flow, the area changes with radius, and the simple formula does not apply.
- Applying the formula before steady state. During heating up, the rod's heat capacity matters and the current varies along the rod.
- Mixing units. Convert cm² to m² (multiply by 10⁻⁴) and cm to m before substituting. The error is easy to make.
- Forgetting that only differences count. Subtracting 273 from both temperatures changes nothing. Adding 273 to only one of them is a mistake.
Why a metal feels colder than wood
A steel spoon and a wooden spoon in the same room are at the same temperature. The steel feels colder because it has a much higher k. It draws heat from your hand faster, so your skin cools faster. You feel the rate of heat loss, not the temperature itself.
Connecting to later topics
The formula has the same structure as Ohm's law, I = ΔV/R. Heat current corresponds to electric current, temperature difference to voltage, and the quantity L/(kA) to resistance. The next chapter develops this idea as thermal resistance and uses it for rods joined in series or in parallel.
Exercise
Two copper rods have the same length. Rod B has twice the radius of rod A. Both have their ends at 100 °C and 0 °C, and the sides are insulated. A carries 8 W. What heat current does B carry? Then, if rod A were replaced by a steel rod (k = 50 W m⁻¹ K⁻¹) of identical size, taking copper as 400 W m⁻¹ K⁻¹, what heat current would it carry?
Show answer
Doubling the radius makes the area four times larger, and everything else is unchanged, so rod B carries 4 × 8 = 32 W. For the steel rod, the rate scales with k, so it carries 8 × 50/400 = 1 W.
Exercise
A glass window pane is 0.5 cm thick with an area of 2 m². The inside surface is at 20 °C and the outside surface is at 10 °C. Taking k = 1 W m⁻¹ K⁻¹, find the heat current through the pane in steady state.
Show answer
Q/t = kA(T₁ − T₂)/L = 1 × 2 × 10 / 0.005 = 4000 W. The thickness of 0.5 cm must be converted to 0.005 m.