Sub topic 13
Thermal resistance in series and parallel
This chapter assumes you know Fourier's law for steady-state conduction, H = kA(ΔT)/L, and that you can solve simple linear equations. It also assumes you know the series and parallel rules for electrical resistors. Here you will use the same algebra for heat flow through combined conductors.
From Fourier's law to resistance
For a uniform rod of conductivity k, cross-section A and length L, with a temperature difference ΔT between its ends, the steady heat current is
H = kAΔT / L
Rearrange it into the form "current = driving difference / resistance":
H = ΔT / R, where R = L / (kA)
R is the thermal resistance. Its SI unit is K/W. A long, thin rod made of a poor conductor has a large R. A short, thick rod made of copper has a small R.
The analogy with electric circuits is exact in steady state:
| Electrical | Thermal |
|---|---|
| Potential difference V | Temperature difference ΔT |
| Current I | Heat current H (watts) |
| Resistance R = ρL/A | Resistance R = L/(kA) |
| Conductivity σ = 1/ρ | Conductivity k |
| Kirchhoff's current rule | Heat in equals heat out at a junction |
The analogy holds only when the flow is steady. If temperatures are still changing, the rods store or release heat, and the simple rules below fail.
Series combination
Rods joined end to end carry the same heat current. In steady state no heat can pile up at a junction, so what enters a rod must leave it. The temperature differences add, because the total drop is the sum of the drops across each rod:
- H is the same through every rod.
- ΔT_total = ΔT₁ + ΔT₂ + ...
- R_series = R₁ + R₂ + ...
For rods of equal cross-section A you can define an equivalent conductivity:
k_eq = (L₁ + L₂) / (L₁/k₁ + L₂/k₂)
The temperature drop across each rod is proportional to its resistance. The rod with the larger R takes the larger share of ΔT.
Parallel combination
Rods connected between the same two end temperatures have the same ΔT. The heat currents add:
- ΔT is the same across every rod.
- H_total = H₁ + H₂ + ...
- 1/R_parallel = 1/R₁ + 1/R₂ + ...
For rods of equal length L and different areas, the equivalent conductivity is
k_eq = (k₁A₁ + k₂A₂) / (A₁ + A₂)
The rod with the smaller R carries the larger share of the current.
Worked example: two rods in series
A copper rod (k = 400 W/(m K)) and a steel rod (k = 50 W/(m K)) are joined end to end. Each is 0.5 m long. Both have the same cross-section, A = 1.0 × 10⁻⁴ m². The free end of the copper is held at 100 °C and the free end of the steel at 0 °C. Find the interface temperature.
Method 1: equal heat currents. In steady state both rods carry the same H:
k₁(Thot − T)/L₁ = k₂(T − Tcold)/L₂
Solving for T gives
T = (k₁Thot/L₁ + k₂Tcold/L₂) / (k₁/L₁ + k₂/L₂)
This is the formula in the code below.
k1, k2 = 400.0, 50.0 # W/(m K), copper and steel, approximate
L1, L2 = 0.5, 0.5 # metres, same cross-section area
T_hot, T_cold = 100.0, 0.0
# In steady state both rods carry the same heat current:
# k1*(T_hot - T)/L1 = k2*(T - T_cold)/L2
T_interface = (k1 * T_hot / L1 + k2 * T_cold / L2) / (k1 / L1 + k2 / L2)
print(round(T_interface, 2)) # 88.89Method 2: resistances. Compute each resistance:
- R₁ = 0.5 / (400 × 1.0 × 10⁻⁴) = 12.5 K/W
- R₂ = 0.5 / (50 × 1.0 × 10⁻⁴) = 100 K/W
- R_series = 112.5 K/W
- H = 100 / 112.5 = 0.889 W
The drop across the copper is H × R₁ = 0.889 × 12.5 = 11.1 K. So the interface is at 100 − 11.1 = 88.9 °C. This matches Method 1.
The interface sits close to the hot end because copper has the small resistance. Most of the 100 K drop happens across the steel.
Same rods in parallel
Now place the same two rods side by side, both connected between 100 °C and 0 °C. Each rod sees the full ΔT = 100 K.
def resistance(k, length, area):
return length / (k * area)
A = 1.0e-4
R_cu = resistance(400.0, 0.5, A) # 12.5 K/W
R_st = resistance(50.0, 0.5, A) # 100 K/W
dT = 100.0
R_series = R_cu + R_st
R_parallel = 1 / (1 / R_cu + 1 / R_st)
print(round(dT / R_series, 4)) # 0.8889 W through the series pair
print(round(dT / R_parallel, 2)) # 9.0 W through the parallel pairIn parallel, the copper carries 100/12.5 = 8 W and the steel carries 100/100 = 1 W, for a total of 9 W. The same two rods conduct about ten times more heat side by side than end to end. Parallel always gives a smaller resistance than the smallest single resistance. Series always gives a larger one than the largest.
Mixed networks and junctions
Reduce a network the same way you reduce a circuit:
- Find groups that are clearly in series or in parallel and replace each with its equivalent R.
- Repeat until one resistance remains, then find the total H from the end-to-end ΔT.
- Work backwards. Use H to get the drop across each series piece. Use the shared ΔT to get the current in each parallel branch.
When three or more rods meet at a single junction at temperature T (a Y-shaped arrangement with no symmetry), reduction does not apply. Instead, apply the junction rule: the heat currents into the junction sum to zero.
Σ (Ti − T) / Ri = 0
Solving for T gives a weighted average of the far-end temperatures, with weights 1/R_i. Your two-rod interface formula is the special case of this with two ends.
If the arrangement is symmetric, look for points at equal temperature first. No heat flows along a rod whose two ends are at the same temperature, so you can remove it from the calculation.
Common errors
- Equal ΔT in series. The temperature drops are equal only if the resistances are equal. What is equal in series is H.
- Equal H in parallel. What is equal in parallel is ΔT. The currents split in inverse proportion to R.
- Using the area of the wrong rod. In series, different areas are fine because H is a total heat current in watts. Only the flux (watts per m²) differs. You cannot say "the flux is the same" unless the areas are equal.
- Mixing units. Use metres, not centimetres, for L and A in R = L/(kA), unless k is also given in a matching unit. A difference in °C equals a difference in K, so you do not need to convert the ΔT.
- Adding conductivities in series. For series you add resistances, not conductivities. The formula for k_eq in series has the harmonic form shown earlier.
- Applying steady-state rules too early. A rod that has just been connected to a hot reservoir is still warming up. The constant-H assumption holds only after the temperatures stop changing.
Summary of the rules
| Quantity | Series | Parallel |
|---|---|---|
| Heat current H | Same in every rod | Adds across rods |
| Temperature difference ΔT | Adds across rods | Same across every rod |
| Equivalent resistance | R = R₁ + R₂ | 1/R = 1/R₁ + 1/R₂ |
| Larger share goes to | Larger R (bigger ΔT) | Smaller R (bigger H) |
Exercise
A rod of aluminium-like material (k = 200 W/(m K)) and a rod of brass-like material (k = 100 W/(m K)) are joined end to end. Each is 0.2 m long and they have the same cross-section. The free end of the first rod is held at 90 °C and the free end of the second at 0 °C. Find the interface temperature in steady state. Then say what happens to the heat current if the two rods are instead connected in parallel between the same temperatures, assuming the same cross-section for each.
Show answer
Using equal heat currents, k₁(90 − T)/L = k₂(T − 0)/L. With equal lengths this gives 200(90 − T) = 100T, so 18000 = 300T and T = 60 °C. In series, the resistances are proportional to L/k, that is 0.001 and 0.002 (in units of 1/A), so the drop across the first rod is one third of 90 K, which is 30 K. That also gives 60 °C. In parallel, each rod sees the full 90 K, so the currents are in the ratio 200 : 100 = 2 : 1, and the total heat current is the sum of the two. This is much larger than the series current. With A the common cross-section, the series current is 90/(0.003/A) = 30000A watts and the parallel current is 90 × 300A/0.2 = 135000A watts, which is 4.5 times as large.
Exercise
Three identical rods each have resistance R. Two are connected in parallel and the pair is connected in series with the third. What is the equivalent resistance, and what fraction of the total heat current flows through each of the two parallel rods?
Show answer
The parallel pair has resistance R/2. Adding the series rod gives 3R/2. All of the total current passes through the single series rod and then splits equally between the two identical parallel rods, so each parallel rod carries one half of the total heat current.