Sub topic 2
Linear Expansion of Solids
Prerequisites
This chapter assumes you can do basic algebra and unit conversion, and that you know the Celsius and Kelvin scales. It also assumes you know what temperature and heat mean from the previous chapter. You need only a loose idea of a rate of change. Calculus appears once, to handle a coefficient that varies with temperature.
Why solids expand
Atoms in a solid vibrate about equilibrium positions. The potential energy curve between two neighbouring atoms is not symmetric about its minimum. It rises steeply when atoms are pushed together and flattens when they are pulled apart. When the temperature rises, the vibrations grow larger. Because the curve is lopsided, the average separation between atoms increases. Summed over many atoms, the whole body gets longer.
If the curve were a perfect parabola, atoms would vibrate more but their average spacing would stay put, and there would be no expansion. Thermal expansion is therefore a direct sign of the asymmetry in interatomic forces.
The basic law
For a thin rod, the change in length is proportional to the original length and to the change in temperature:
ΔL = α L₀ ΔT
- L₀ is the length at the starting temperature.
- ΔT is the change in temperature, T₂ − T₁.
- α is the coefficient of linear expansion, a property of the material.
The final length is
L = L₀ (1 + α ΔT)
The unit of α is per kelvin (K⁻¹), which is the same as per °C (°C⁻¹). This holds because α multiplies a temperature difference, and a difference of 1 K equals a difference of 1 °C. You never need to convert ΔT between the two scales. You do need to convert if a problem gives the temperatures in °F, since a 1 °F change is 5/9 K.
Here are approximate values.
| Material | α (10⁻⁶ K⁻¹) |
|---|---|
| Aluminium | 23 |
| Brass | 19 |
| Copper | 17 |
| Steel | 12 |
| Glass (ordinary) | 9 |
| Pyrex | 3 |
| Invar | about 1 |
Typical values are of order 10⁻⁵ K⁻¹. A rod heated by 100 K therefore grows by only about 0.1 percent. Expansion is small in relative terms, but it is large enough to buckle rails and crack bridges.
Worked example in code
A 1 m aluminium rod is heated by 50 K. The program below applies the formula.
alpha_aluminium = 2.3e-5 # per kelvin, approximate
L0 = 1.0 # metres
delta_T = 50.0 # kelvin
delta_L = alpha_aluminium * L0 * delta_T
print(delta_L) # about 0.00115 m, i.e. 1.15 mmThe rod grows by about 1.15 mm, a fractional change of 0.115 percent.
Fractional change and the "small change" approximation
Rearranging the law gives
ΔL / L₀ = α ΔT
The left side is the fractional change (or strain) in length. This form is useful because many JEE problems give or ask for a percentage change. For example, if a rod's length increases by 0.1 percent when heated by 50 K, then α = 0.001 / 50 = 2 × 10⁻⁵ K⁻¹.
The law is an approximation. It treats α as constant and assumes ΔL is much smaller than L₀. For solids over moderate ranges, both assumptions are good. If a problem heats a rod over a very wide range, you may be told α changes with temperature.
When α depends on temperature
If α varies with T, the exact relation is differential:
dL / L = α(T) dT
Integrating from T₁ to T₂ gives
ln(L₂ / L₁) = ∫ α(T) dT
If α is constant this becomes L₂ = L₁ e^(αΔT), which is nearly L₀(1 + αΔT) whenever αΔT is tiny. Because αΔT is typically about 10⁻³, the two forms agree to about one part in a million. Use the simple linear formula unless the question explicitly states a temperature-dependent α.
If α(T) = a + bT, the integral gives a(T₂ − T₁) + (b/2)(T₂² − T₁²). Follow the integral. Do not simply use the average α unless the question says to.
Expansion of holes and gaps
A common mistake is to think that a hole in a plate shrinks when the plate is heated because "the metal expands into the hole." It does the opposite.
A hole expands exactly as if it were filled with the same material. Imagine a disc of the plate's material fitting the hole perfectly. When heated, the disc grows by a factor (1 + αΔT) in every dimension. The surrounding plate grows by the same factor, because every length in the body scales uniformly. So the hole's diameter grows by the same ratio.
The same reasoning applies to any gap, such as the distance between two marks on a rod, the inner diameter of a ring, or the gap between two rail ends. Every distance measured on the body scales by (1 + αΔT).
This is why a metal ring that is slightly too small can be slipped over a shaft by heating it. The ring's inner diameter increases. After cooling, the ring grips the shaft tightly. This is a shrink fit.
Two rods and the condition for a constant difference
Two rods of different materials have lengths L₁ and L₂ at some temperature. Their lengths after a temperature change ΔT are
L₁′ = L₁(1 + α₁ΔT), L₂′ = L₂(1 + α₂ΔT)
The difference in lengths stays constant if the expansions are equal:
α₁ L₁ = α₂ L₂
This is the standard JEE condition. Under this relation, the extra length of one rod always equals the extra length of the other, whatever the temperature change. It is the basis of the question "what lengths must a steel rod and a copper rod have so that their difference is 10 cm at every temperature?"
For example, take copper (α = 17 × 10⁻⁶) and steel (α = 12 × 10⁻⁶), with copper longer by 10 cm. The condition gives 17 LCu = 12 Lsteel. With LCu − Lsteel = −10 cm we would need Lsteel > LCu, which is the correct way round, since steel has the smaller α and so must be longer. Let Lsteel = LCu + 10. Then
17 LCu = 12 (LCu + 10) 5 LCu = 120 LCu = 24 cm, L_steel = 34 cm
The steel rod is longer, so the difference is steel minus copper. You can confirm this by checking 17 × 24 = 408 and 12 × 34 = 408.
Measuring a changing length with a ruler
A metal scale is calibrated at one temperature. At a different temperature the scale itself has expanded, so its markings are farther apart than they claim to be. This affects how you read lengths.
- If the scale expands (the temperature is above the calibration temperature), each division is longer than labelled. The scale reads less than the true length.
- If the scale contracts (below calibration), it reads more than the true length.
The relation is
true length = reading × (1 + α_scale ΔT)
where ΔT is measured from the calibration temperature. If the object being measured also expands, include its expansion in the reading as well. For a steel scale reading a brass rod, the reading at temperature T is the true length of the rod divided by (1 + α_steel ΔT).
Temperature-dependent timekeeping
A pendulum clock uses the idea of the previous section, because the period depends on length. This chapter only mentions the effect. The next chapters apply it in full. A rod that lengthens makes the clock run slow, since T ∝ √L. The fractional change in period is half the fractional change in length: ΔT/T = ½ αΔT.
Mapping the idea
The diagram shows how the pieces of this chapter fit together.
Common errors
- Using ΔT in the wrong scale. Celsius and kelvin differences are identical, but Fahrenheit differences are not.
- Shrinking the hole. Holes grow when the body is heated.
- Using the final length as L₀. The law uses the original length. The difference matters little for small α, but it can cost the last digit in a numerical-answer question.
- Mixing up which rod is longer in a constant-difference problem. The material with the smaller α needs the greater length.
- Reversing the scale error. A hot metal scale reads too small a value.
- Forgetting units. If α is in K⁻¹ and L₀ is in centimetres, ΔL comes out in centimetres.
Checking a result
After you compute ΔL, ask two questions. First, is ΔL/L₀ of order 10⁻³ or smaller for a modest ΔT? If you get a value like 0.5, you probably forgot a factor of 10⁻⁶ in α. Second, does the sign match the physics? Heating gives a positive ΔL, and cooling gives a negative one.
Exercise
A steel tape is calibrated at 20 °C (α_steel = 1.2 × 10⁻⁵ K⁻¹). On a hot day at 40 °C it reads 50.00 m for the length of a field. What is the true length of the field? Also, a copper plate has a circular hole of diameter 4.000 cm at 20 °C. The copper has α = 1.7 × 10⁻⁵ K⁻¹. What is the hole's diameter at 120 °C?
Show answer
At 40 °C the tape has expanded, so each marked metre is longer than 1 m. True length = reading × (1 + αΔT) = 50.00 × (1 + 1.2 × 10⁻⁵ × 20) = 50.00 × 1.00024 = 50.012 m. For the hole, the hole expands like the material: D = 4.000 × (1 + 1.7 × 10⁻⁵ × 100) = 4.000 × 1.0017 = 4.0068 cm.
Exercise
A brass rod (α = 1.9 × 10⁻⁵ K⁻¹) and an iron rod (α = 1.2 × 10⁻⁵ K⁻¹) differ in length by 28 cm at every temperature. Find the length of each rod at 0 °C.
Show answer
The difference is constant, so αbrass Lbrass = αiron Liron. Iron has the smaller α, so iron is longer. Let Liron = Lbrass + 28. Then 19 Lbrass = 12 (Lbrass + 28), so 7 Lbrass = 336 and Lbrass = 48 cm. L_iron = 76 cm. Check: 19 × 48 = 912 and 12 × 76 = 912.