Sub topic 8
Power Problems and Protective Devices
This chapter assumes you know basic PC hardware and the difference between AC wall power and the DC power a power supply unit (PSU) delivers to components. The A+ exam asks you to name a power problem from a short description and pick the device that addresses it.
The Common Power Problems
Utility power is meant to be a steady voltage. Several faults can disturb it.
| Problem | What happens | Typical effect |
|---|---|---|
| Blackout | Total loss of power | Computer shuts off and unsaved work is lost |
| Brownout (sag) | Voltage drops below normal for a period | Random reboots, freezes, stressed PSU |
| Surge | Voltage rises above normal for a short time | Damage to the PSU and components |
| Spike | Very brief, very high voltage jump, such as from a lightning strike | Immediate hardware damage |
| Noise | Electrical interference (EMI or RFI) on the line | Data errors, humming, flicker |
The terms "sag" and "brownout" are close in meaning. A sag is a short dip. A brownout is a longer one. Exam questions usually accept either when the symptom is low voltage.
Matching Problems to Devices
Each device covers a different set of problems.
- Surge protector: Absorbs extra voltage from surges and spikes. It does nothing during a blackout or a sag. Many models wear out after taking large hits, so replace them on a schedule or after a major event. Check the joule rating, since a higher number means more energy absorbed. Many units also have an indicator light that shows whether the protection is still working.
- Battery backup, or uninterruptible power supply (UPS): Holds a battery that keeps equipment running briefly during a blackout or sag. It gives you time to save work and shut down cleanly. Most also include surge protection.
- Line conditioner: Smooths out sags, surges, and noise without relying on a battery.
- Power strip: Adds outlets only. It gives no protection unless it is also a surge protector.
UPS Types
Two UPS designs appear most often.
- Standby (offline): Runs equipment from wall power and switches to the battery when power fails. The switch takes a few milliseconds. It costs less.
- Line-interactive or online (double conversion): Online units always run equipment from the battery circuit, so there is no switchover. They cost more and suit servers.
Size a UPS by the load it must carry, measured in volt-amperes (VA) or watts. Add up the draw of every connected device and choose a unit with spare capacity.
Practical Checks
When a user reports random reboots, ask whether the machine shares a circuit with heavy appliances. Test the outlet with a receptacle tester, and check that the equipment is on a surge protector or UPS. Never daisy-chain surge protectors or power strips. Doing so can overload the wall circuit and create a fire risk.
Exercise
A server room loses power for 20 seconds during a storm. The servers shut off and lose unsaved data. Which device would have prevented the data loss, and why would a surge protector alone not have helped?
Show answer
A UPS would have prevented it, because its battery keeps the servers running through the outage and gives time for a clean shutdown. A surge protector only absorbs excess voltage. It does not supply power when the voltage drops to zero.
Exercise
A user's workstation reboots at random at the same time each afternoon, when a space heater on the same circuit switches on. Name the power problem and one suitable device.
Show answer
The problem is a sag or brownout caused by the heater's load. A UPS or a line conditioner would help, and moving the heater to another circuit would address the cause.