Sub topic 15
Intensity, hardness and uses of X-rays
This chapter assumes you know how X-rays are produced in a Coolidge tube, the Duane-Hunt cut-off wavelength λ_min = hc/(eV), and Moseley's law for characteristic lines. It also assumes you can handle photon energy E = hc/λ with hc ≈ 1240 eV·nm. Here you will separate two quantities that students often mix up: how many X-rays a tube emits (intensity) and how penetrating they are (hardness). Then you will see how both control the practical uses of X-rays.
Two independent controls on a tube
A Coolidge tube has two electrical circuits. They control different properties of the beam.
- The filament circuit heats the cathode. Its current sets how many electrons are emitted per second by thermionic emission.
- The high-voltage circuit sets the potential difference V between cathode and target. It sets the kinetic energy eV each electron has when it hits the target.
The first circuit controls the number of electrons. The second controls the energy of each electron. Everything in this chapter follows from this split.
| Change | What it controls | Effect on the beam |
|---|---|---|
| Raise filament current | Number of electrons per second (tube current I) | More X-ray photons per second. The spectrum has the same λ_min and the same line positions. |
| Raise tube voltage V | Energy per electron | λ_min decreases. Photons are more energetic. Total intensity also rises. |
| Change target element (Z) | Which characteristic lines appear | Line positions change as (Z − b)². The continuous spectrum has the same λ_min. |
Intensity
The intensity of an X-ray beam is the energy that crosses unit area per unit time. It is the number of photons per second per unit area multiplied by the energy of each photon. A count of photons alone is not intensity, because photons differ in energy.
For the continuous spectrum, the total power emitted is roughly proportional to Z·I·V². So the intensity depends on:
- The tube current I, which sets the number of electrons striking the target.
- The tube voltage V, because each electron carries more energy and more of it is radiated.
- The atomic number Z of the target.
At JEE level, the key point is the first one. Intensity is proportional to the tube current, which is set by the filament temperature. If you double the filament current's effect so that the electron emission doubles, the number of photons at every wavelength doubles. The cut-off wavelength does not move.
Only a small fraction of the beam power becomes X-rays. Most of the electron beam energy, usually more than 99 percent at the voltages used in medical tubes, becomes heat in the target. This is why targets are made of tungsten (high melting point, high Z) and are often mounted on rotating anodes or cooled with oil or water.
Hardness
Hardness describes the penetrating power of X-rays. It depends on photon energy, so it depends on the tube voltage.
- Hard X-rays have short wavelength and high photon energy. They pass through matter easily. They are produced at high tube voltage.
- Soft X-rays have longer wavelength and lower photon energy. They are absorbed more strongly. They are produced at low tube voltage.
Because λ_min = 12400/V (with λ in ångström and V in volts), raising the voltage shifts the whole continuous spectrum toward shorter wavelengths. The beam becomes harder.
The reverse mistake is also common. Raising the voltage does increase total intensity, but it does so because each electron delivers more energy. The reason hardness changes is the shift in λ_min, not the count of photons.
Reading the spectrum shape
The intensity-versus-wavelength graph has a smooth continuous hump with sharp peaks on top. The hump starts at λ_min, rises to a maximum, and then falls slowly. The sharp peaks are the characteristic lines.
Two points about the graph matter in problems.
- When V rises, the characteristic lines do not move. Their wavelengths belong to the target atoms. A line appears only if V is large enough for incident electrons to knock out the inner electron involved. If the voltage is below that threshold, the continuous hump is present and the line is absent.
- When the target changes but V stays the same, λ_min stays the same. The lines move.
Absorption of X-rays
When a beam passes through a material, its intensity falls exponentially with thickness x:
I = I₀ e^(−μx)
Here μ is the linear attenuation coefficient. It is larger for dense materials and for high-Z materials. It is smaller for harder X-rays. This is the physical basis of the hardness idea: a hard beam has a small μ in a given material, so it travels further.
The half-value thickness x½ is the thickness that cuts the intensity to one half. Setting I = I₀/2 gives x½ = ln 2 / μ.
The following program computes the transmitted fraction through several thicknesses.
import math
mu = 0.5 # linear attenuation coefficient in 1/cm
half_value = math.log(2) / mu
print("half-value thickness (cm):", round(half_value, 3))
for x in [1, 2, 4, 6]:
fraction = math.exp(-mu * x)
print(x, "cm ->", round(fraction, 3))The output shows a half-value thickness of about 1.386 cm. After 4 cm the transmitted fraction is about 0.135.
Absorption differs between materials because bone contains calcium (Z = 20) and soft tissue is mostly light elements (carbon, hydrogen, oxygen). Heavy elements absorb X-rays far more strongly. That contrast makes a medical radiograph possible.
Properties of X-rays
The following properties are standard in JEE questions.
- X-rays are electromagnetic waves with wavelength from about 0.01 nm to 10 nm. They travel at c in vacuum.
- They are not deflected by electric or magnetic fields, because they carry no charge. This distinguishes them from cathode rays, which are electron streams.
- They affect photographic plates and cause fluorescence in some materials.
- They ionize gases, and this is used in detectors.
- They show diffraction from crystals, because interatomic spacing in a crystal (about 0.1 nm) is comparable to X-ray wavelength.
- They can eject electrons from metals by the photoelectric effect.
- They are not refracted noticeably by ordinary lenses, because the refractive index of matter for X-rays is extremely close to 1.
Bragg's law for crystal diffraction
When X-rays reflect from parallel crystal planes with spacing d, the reflected beams reinforce when 2d sin θ = nλ. Here θ is the glancing angle measured from the plane, not from the normal. A crystal therefore works as a diffraction grating for X-rays and lets you measure wavelength when d is known, or measure d when λ is known.
Uses
The use of a beam depends on its hardness and intensity.
| Use | Why X-rays suit it |
|---|---|
| Medical radiography | Bone absorbs more than soft tissue, so the shadow shows fractures. |
| CT scanning | Many projections at different angles are combined into a cross-section image. |
| Cancer radiotherapy | Hard, high-energy beams deliver energy deep inside tissue and damage tumor cells. |
| Crystallography | Diffraction patterns give atomic spacings and structures of crystals and molecules. |
| Airport and industrial inspection | Absorption differences reveal hidden objects and internal flaws in castings and welds. |
| Elemental analysis | Characteristic lines identify the elements in a sample through Moseley's law. |
Medical imaging usually uses a moderate voltage so that the contrast between bone and tissue is good. Radiotherapy uses much higher energies so the beam reaches deep tumors.
Worked example
A tube operates at 40 kV with a tube current of 10 mA. Find the minimum wavelength and the number of electrons striking the target per second. Then state the effect of doubling the voltage and halving the current.
hc_eV_angstrom = 12400
V = 40000
I = 10e-3
e = 1.6e-19
lambda_min = hc_eV_angstrom / V
electrons_per_s = I / e
print(lambda_min) # 0.31 angstrom
print(electrons_per_s) # 6.25e16 per second
lambda_min_new = hc_eV_angstrom / (2 * V)
print(lambda_min_new) # 0.155 angstromThe minimum wavelength is 0.31 Å, and 6.25 × 10¹⁶ electrons strike the target each second. Doubling the voltage halves λ_min to 0.155 Å, so the beam is harder. Halving the current halves the number of electrons per second. Total intensity depends on both changes, so it rises by a factor of about 2 (since power scales as I·V², giving 0.5 × 4 = 2). The characteristic lines keep the same wavelengths.
Common errors
- Linking intensity to voltage alone. Current also matters, and current is the dominant control at fixed V.
- Linking hardness to filament current. It is set by voltage.
- Expecting characteristic line wavelengths to shift with voltage. They shift only with the target element.
- Using the angle from the normal in Bragg's law. The angle is measured from the plane.
- Saying X-rays are deflected by magnetic fields. They are not.
Exercise
An X-ray tube runs at 25 kV with tube current 8 mA. The filament current is then raised so that the tube current becomes 16 mA, and the voltage is left unchanged. (a) Find λ_min before and after. (b) By what factor does the intensity at each wavelength change? (c) Does the beam become harder? Use hc = 12400 eV·Å.
Show answer
(a) λ_min = 12400/25000 = 0.496 Å both before and after, since it depends only on V. (b) The number of electrons per second doubles, so the number of photons at each wavelength doubles and the intensity at each wavelength doubles. (c) No. The cut-off wavelength and the photon energies are unchanged, so hardness is unchanged. Only intensity increased.
Exercise
A parallel beam of X-rays has intensity I₀ and passes through a slab with μ = 0.3 cm⁻¹. What thickness reduces the intensity to one eighth? Take ln 2 = 0.693.
Show answer
One eighth means three half-value thicknesses. x_½ = 0.693/0.3 = 2.31 cm, so x = 3 × 2.31 = 6.93 cm. Equivalently, e^(−μx) = 1/8 gives μx = 3 ln 2 = 2.08, so x = 6.93 cm.